Regency
®
PG36-5 Gas Log Fireplace
12
Flue Adapter
(Part# 510-994)
Pipe Length
Round Support
Box/Wall Thimble
(Part # 940)
Round
Support Box/
Wall Thimble
(Part # 940)
Vertical
Terminal
Storm Collar
Part # 953
Flashing
943 or 943S
Ceiling Firestop
(Part # 963)
24" (610mm)
Pipe Length
Adj.Pipe Length
11" - 14-5/8"
(279mm - 372mm)
90 Elbow
o
AstroCap
Wall Thimble
Part # 942
Vinyl Siding
Standoff (Optional)
Part #950
INSTALLATION
Simpson Dura-Vent
Co-Axial Flue GS
SIMPSON DURA-VENT FLUEING
Horizontal or Vertical Terminations
The Simpson Dura-Vent Co Axial Flue System offers a complete line of component parts for installation of both horizontal and vertical installations. Many
items are offered in decorative black, as well as galvanized fi nish. We recommend using the galvanized fi nish for installation with the PG36.
The minimum components required for a basic
horizontal termination are:
1 Horizontal
Termination
Cap
1 90
o
Elbow
1 Flue
Adaptor
1 Wall
Thimble
1 Length of pipe to suit wall thickness
(see
chart)
If a Vinyl Siding Standoff is required (it must
be used with vinyl siding), measure to outside
surface of wall without siding and add 2
inches.
SIMPSON DURA-VENT FLUEING COMPONENTS LIST
All Simpson Dura-Vent components are available directly from Masport.
971
Horiz. Termination Kit includes: 90
o
black
elbow, wall thimble cover, horiz. square
termination cap, 24" black pipe, and 11"
-14" 5/8" adjustable black pipe
970
Basic Horiz. Termination. Kit includes:
90
o
black elbow, wall thimble cover,
horiz. square termination cap
978
Vert. Termination Kit includes 0/12 -
6/12
pitch
adjustable
fl ashing, storm
collar, low profi le term. cap
908B 6" (152mm) Pipe Length - Black
907B 9" (229mm) Pipe Length - Black
906
12" (305mm) Pipe Length - Galv.
906B 12" (305mm) Pipe Length - Black
904
24" (610mm) Pipe Length - Galv.
904B 24" (610mm) Pipe Length - Black
903
36" (914mm) Pipe Length - Galv.
903B 36" (914mm) Pipe Length - Black
902
48" (1219mm) Pipe Length - Galv.
902B 48" (1219mm) Pipe Length - Black
911B
11"-14 5/8" (279mm - 372mm) Adjustable
Pipe Length - Black
917B 17"- 24" (432mm - 610mm) Adjustable
Length - Black
945 45
O
Elbow - Galv.
945B 45
O
Elbow - Black
945G 45
O
Elbow - Swivel - Galv.
945BG 45
O
Elbow - Swivel - Black
990 90
O
Elbow - Galv.
990B 90
O
Elbow - Black
990G 90
O
Elbow - Swivel - Galv.
990BG 90
O
Elbow - Swivel - Black
991
High Wind Termination Cap (Vertical)
980 Vertical
Termination
Cap
984
Horizontal Square Termination Cap
985
Horiz. Square High Wind
Termination
Cap
982
Snorkel - 14"(356mm) Rise Term.Cap
981
Snorkel - 36" (914mm) Rise
Termination
Cap
940
Wall Thimble - Support/Box
941
Cathedral/Ceiling - Support/Box
3951 Brass Trim for Wall Thimble/
Ceiling
Sup.
963 Firestop
Spacer
943 Flashing
0/12-6/12
943S Flashing 7/12-12/12
953 Storm
Collar
950
Vinyl Siding Standoff
988 Wall
Strap
942 Wall
Thimble
Parts not supplied by Dura-Vent
946-506/P
Flue Guard (Optional)
510-994 Dura-Vent
Flue
Adaptor
640-530/P Riser
Flue
Terminal
946-205 Vinyl Siding Shield for Riser Flue
Terminal
Part # Description
Part # Description
Part # Description
Flat Wall Installation
Wall Thickness
(inches)
Vent Length Required
(inches)
4" - 5-1/2"
6"
7" - 8-1/2"
9"
10" - 1-1/2"
12"
9" - 14-1/2"
11" - 14-5/8" Adj. Pipe
15" - 23-1/2"
17" - 24" Adj.
Corner Installation
Wall Thickness
(inches)
Vent Length Required
(inches)
3-1/4" - 6-3/4"
11" - 14-5/8" Adj. Pipe
7-3/4" - 16-1/4"
17" - 24" Adj. Pipe
7-1/4" - 8-3/4"
6" + 12"
9" + 9"
4-1/4" - 5-3/4"
6" + 9"
Wall thickness is measured from the back
standoffs to the inside mounting surface of
termination cap. For siding other than vinyl furring
strips may be used, instead of the vinyl siding
standoff, to create a level surface to mount the
fl ue terminal. The Terminal must not be recessed
into siding. Measure the wall thickness including
furring strips.