background image

Regency PG33NG4-R Gas Inbuilt

5

installation

IMPORTANT:  

SAVE THESE 

INSTRUCTIONS

The P33-NG or P33-LPG Direct Flue Fireplace must 

be installed in accordance with these instructions. 

Carefully read all the instructions in this manual 

first. Consult the "authority having jurisdiction" to 

determine the need for a permit prior to starting the 

installation. It is the responsibility of the installer 

to ensure this fireplace is installed in compliance 

with manufacturer's instructions and all applicable 

codes.

BEFORE YOU START

Safe installation and operation of this appliance 

requires common sense, however, we are required 

by the Canadian Safety Standards and ANSI Stand

-

ards to make you aware of the following:

MANUFACTURED 

MOBILE HOME

ADDITIONAL 

REQUIREMENTS

1)

  Ensure that structural members are not cut or 

weakened during installation.

2)

  Ensure proper grounding using the #8 ground 

lug provided. See page 35.

GENERAL SAFETY IN-

FORMATION

1)

  The appliance shall be installed in accord-

ance  with  the  manufacturer's  installation 

instructions,local  gas  fitting  regulations,  mu

-

nicipal building codes, water supply regulations, 

electrical wiring regulations, with AS5601-2004 

(AGA gas installation code) NZS 5261 (New 

Zealand)

2)

 

Installation and repair should be done ONLY 

by an authorised person.  

3)

 

THIS APPLIANCE IS NOT INTENDED AS A 

FIREPLACE INSERT. DO NOT CONNECT TO 

MASONARY FLUE.

4)

 

This appliance must be connected to the 

specified  flue  and  termination  cap  to  the 

outside of the building envelope. Never flue 

to another room or inside a building. Make 

sure  that  the  flue  is  fitted  as  per  Flueing 

instructions.

5)

  Inspect the flueing system annually for blockage 

and any signs of deterioration.   

6)

  Flueing terminals shall not be recessed into a 

wall or siding.

7)

  Any safety glass removed for servicing must 

be replaced prior to operating the appliance.

8)

  To prevent injury, do not allow anyone who is 

unfamiliar with the operation to use the fireplace.

9)

  Wear gloves and safety glasses for protection 

while doing required maintenance.

10)

 Be aware of electrical wiring locations in walls 

and ceilings when cutting holes for termination.

11)

 Under no circumstances should this appliance 

be modified. Parts that have to be removed for 

servicing should be replaced prior to operating 

this appliance.

12)

 Installation and any repairs to this appliance 

should be done by an authorised service per

-

son. An authorised service person should be 

called to inspect this appliance annually. Make 

it a practice to have all of your gas appliances 

checked annually.

13)

 Do not slam shut or strike the glass door.

14)

 Under no circumstances should any solid fuels 

(wood, paper, cardboard, coal, etc.) be used in 

this appliance.

15)

 The  appliance  area  must  be  kept  clear  and 

free of combustible materials, (gases and other 

flammable vapours and liquids).

CLOTHING OR OTHER FLAMMABLE 
MATERIAL SHOULD NOT BE PLACED 
ON OR NEAR THE APPLIANCE.

   

CHILDREN AND ADULTS SHOULD BE 
ALERTED TO THE HAZARDS OF HIGH 
SURFACE TEMPERATURES,  ESPE-
CIALLY THE FIREPLACE GLASS, AND 
SHOULD STAY AWAY TO AVOID BURNS 
OR CLOTHING IGNITION.  

INSTALLATION AND REPAIR SHOULD 
BE DONE BY AN AUTHORIZED 
SERVICE PERSON. THE APPLIANCE 
SHOULD BE INSPECTED BEFORE 
USE AND AT LEAST ANNUALLY BY A 
PROFESSIONAL SERVICE PERSON. 
MORE FREQUENT CLEANING MAY 
BE REQUIRED DUE TO EXCESSIVE 
LINT FROM CARPETING, BEDDING 
MATERIAL, ETC. IT IS IMPERATIVE THAT 
CONTROL COMPARTMENTS, BURNERS 
AND CIRCULATING AIR PASSAGEWAYS 
OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE 
APPLIANCE SHOULD BE LOCATED 
OUT OF TRAFFIC AND AWAY FROM 
FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS 
APPLIANCE CORRECTLY WILL VOID 
YOUR WARRANTY AND MAY CAUSE A 
SERIOUS HOUSE FIRE.

YOUNG CHILDREN SHOULD BE CARE-
FULLY  SUPERVISED WHEN THEY ARE 
IN THE SAME AREA AS THE APPLI-
ANCE.  TODDLERS, YOUNG CHILDREN 
AND OTHERS MAY BE SUSCEPTIBLE 
TO ACCIDENTAL CONTACT BURNS.  A 
PHYSICAL BARRIERS IS RECOMMEND-
ED IF THERE ARE AT RISK INDIVIDUAL 
IN THE HOUSE.  TO RESTRICT ACCESS 
TO A FIREPLACE OR STOVE, INSTALL 
AN ADJUSTABLE SAFETY GATE TO 
KEEP TODDLERS, YOUNG  CHILDREN 
AND OTHER AT RISK INDIVIDUALS OUT 
OF THE ROOM AND AWAY FROM HOT 
SURFACES. 

Содержание Panorama PG33LPG4-R

Страница 1: ...ause injury or property damage Refer to this manual For assistance or additional in formation consult an authorised installer service agency or the gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flam mable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorised installer service agency or the gas supplier Pa...

Страница 2: ...h and charm of a wood fireplace The model PG33 has been approved by the Australian Gas Association for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace ...

Страница 3: ...tem and 16 REGENCY DIRECT FLUE SYSTEM FLEX 16 NG LPG ULPG with ULPG Burner 16 Minimum 16 Simpson Dura Flue Center Line 16 Minimum Flex Kit Center Line 16 Flueing arrangements horizontal terminations 17 Simpson dura flue direct flue gs system and 17 Regency direct flue system flex 17 ULPG with NG LPG Burner 17 Horizontal installations 21 Vertical Termination 22 Gas connection 23 Gas pipe pressure T...

Страница 4: ...rd Jan 9 14 Rev D updated E Aus address Sept 27 16 Rev E updated model name Electrical 240VAC 50Hz 1 0 amp max Serial Number 918 326e N2134 Regency Gas Fireplace 269 Gas Type NG LPG ULPG Model PG33NG4 R PG33LPG4 R PG33ULPG4 R Gas Consumption 23 7mj 23 5mj 20 3mj Manifold Pressure 0 95 kPa 2 61 kPa 2 40 kPa Injector Size 1x 44 1x 54 1x 55 2 18mm 1 4mm 1 32mm Model AGA 6702 G AS 4553 Distributed by ...

Страница 5: ...es for protection while doing required maintenance 10 Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination 11 Under no circumstances should this appliance be modified Parts that have to be removed for servicing should be replaced prior to operating this appliance 12 Installation and any repairs to this appliance should be done by an authorised service pe...

Страница 6: ...e is not the responsibility of the manufacturer LOCATING YOUR GAS STOVE Diagram 1 1 When selecting a location for your stove ensure that the clearances outlined on this page are met 2 Provide adequate clearances for servicing 3 The appliance must be installed on a flat solid continuous surface e g wood metal concrete Thismaybethefloor orraisedup on a platform to enhance its visual impact If the ap...

Страница 7: ...below Maximum CLEARANCES A major cause of chimney related fires is failure to maintain required clearances air space to combustible materials It is of the greatest importance that this fireplace and flue system be installed only in accordance with these instructions Clearance to Combustibles from Back 0 0mm Side 0 0mm Floor 0 0mm NOTE The minimum floor clearance must be maintained from the top sur...

Страница 8: ...socombustiblebuildingmaterialscan belaiddirectlyontopofthestandoffs Youmustmaintainclearancefromthe flue to combustible materials for flex for Simpson Dura Flue see page 7 6 Use steel studs for framing where the 1 1 2 38mm clearance from the flue to combustible material cannot be maintained FRAMING AND FINISHING 16 1 2 419mm Minimum 4 102mm 3 76mm 1 1 2 38mm 30 762mm 10 254mm dia Hole through wall...

Страница 9: ...Support using the 3 supplied screws into the three pre punched screwholesonthetopfrontoftheunit Adjust support to desired facing material depth 2 MountSideNailingStripusingthe3supplied screws into the three pre punched screw holes at the front sides of the unit Adjust supporttodesiredfacingmaterialthickness UNIT ASSEMBLY PRIOR TO INSTALLATION Top Facing Support Side Nailing Strips folded out FLUEI...

Страница 10: ... air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I Appliances up to 150 MJ h input 500 Appliances over 150 MJ h input 1500 k Vertically below an openable window door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I see table below NOTES I For mechanical air inlets in...

Страница 11: ...acers 3 4 thimble 2 5 AstroCap termination cap 1 6 screws 12 7 tube of Mill Pac 1 8 plated screws 8 9 screws 8 x 1 1 2 drill point stainless steel 4 Wherevernecessaryduetoexternal location of cap the AstroCap can be replaced with the FPI Riser Flue Termination Cap or the Dura Vent Snorkel Termination Cap See also Figure 1 below Notes 1 Linersectionsshouldbecontinuouswithoutany joints or seams 2 On...

Страница 12: ...screws through the nailing strips 3 Assemble the flue assembly by applying Mill Pac to the 4 100mm inner collar of the terminationand slippingthe4 100mm liner over it at least 1 3 8 35mm Fasten with the3screws drillingpilotholeswillmakethis easier Apply Mill Pac or high temperature silicone to the 6 7 8 175mm flex pipe and slip it over the 6 7 8 outer collar of the flue terminal at least 1 3 8 35m...

Страница 13: ...himble 1 Length of pipe to suit wall thickness see chart For siding other than vinyl furring strips may be used instead of the vinyl siding standoff to cre ate a level surface to mount the flue terminal The Terminal must not be recessed into siding If a Vinyl Siding Standoff is required it must be used with vinyl siding measure to outside surface of wall without siding and add 2 inches The Regency...

Страница 14: ...llowable combinations of straight vertical and offset to vertical terminations using one 90o elbow with Simpson Dura Flue Direct Flue GS flue systems for NG LPG and ULPG Minimum 8 6 2 6m Maximum 40 12 2m 40 8 10 12 14 16 18 20 22 24 26 28 30 6 0 2 4 2 0 6 4 Vertical Height ft m Horizontal ft m 5 5m 1 8m 3 7m 7 3m 9 1m 0 6m 1 2m 1 8m 10 9m 10 4m 9 8m 8 5m 7 9m 6 7m 6 1m 4 9m 4 3m 3 0m 2 4m 0 6m 1 2...

Страница 15: ...alandoffsettoverticalterminationswithSimpsonDura FlueDirectFlue GS flue systems for LPG ULPG and NG Maximum two 45o elbows allowed Flue must be supported at offsets Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustibles Horizontal M Maximum 40 ft 12 2m Minimum 9 6 2 9m Minimum 8 6 2 6m Vertical Height M 3 3 6 4 2 4 8 5 4 6 6 6 7 2 8 8 6 9...

Страница 16: ...s Horizontal flue must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A flue guard should be used whenever the termination is lower than the specified minimum or as per local codes Note Regency Direct Flue System Flex is onlyapprovedforhorizontaltermina tions Minimum Simpson Dura Flue Center Line Minimum Flex Kit Center Line Min 30 762mm Ma...

Страница 17: ...ng one 45o and one 90o elbow two 45o elbows equal one 90o elbow Note Must use optional flue adapter Part 510 994 when using Simpson Dura Vent pipe Refer to page 13 Maintain clearances to combustibles Horizontal flue must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A flue guard should be used whenever the termination is lower than the spe...

Страница 18: ...E 1 5m Min 2 1m Max F 1 8m Min 2 4m Max Option H V H H1 H2 With these options max total pipe length is 30 feet with min of 11 feet total vertical and max 9 feet total horizontal Please note min 1 foot between 90o elbows is required A 0 3m Max 0 3m Min 0 9m Max B 0 6m Max 0 9m Min 1 5m Max C 0 9m Max 1 5m Min 1 8m Max D 1 2m Max 2 1m Min 2 1m Max E 1 5m Max 2 7m Min 2 7m Max F 1 8m Max 3 3m Min 2 7...

Страница 19: ...in A 0 3m 1 2m 0 6m B 0 6m 1 5m 0 9m C 0 9m 1 8m 1 2m D 1 2m 2 1m 1 5m E 1 5m 2 4m 1 8m Vertical Flueing with Two 2 90o Elbows With these options max total pipe length is 30 feet with min of 6 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is re quired Option H H1 V Max Min A 0 6m 0 6m B 0 9m 0 9m C 1 2m 1 2m D 1 5m 1 5m E 1 8m 1 8m Withtheseoptions m...

Страница 20: ... max 8 feet total horizontal Please note min 1 foot between 90o elbows is required Vertical Flueing with Three 3 90o Elbows Option H V H H1 V V1 Max Min Max Min A 0 3m 0 3m 0 9m 0 9m B 0 6m 0 6m 1 2m 1 5m C 0 9m 0 9m 1 5m 2 1m D 1 2m 1 2m 1 8m 2 7m E 1 5m 1 5m 2 1m 3 3m With these options max total pipe length is 30 feet with min of 11 feet total vertical and max 7 feet total horizontal Please not...

Страница 21: ...visible from the outside on the Black Pipe or fittings They may be located by examining the inside of the female ends Note Apply sealant Mill Pac to inner pipe and high temperature silicone sealant to outer pipe on every twist lock joint b Horizontal runs of flue must be supported every three feet Wall straps are available for this purpose 5 Mark the wall for a 10 254mm x 10 254mm square hole The ...

Страница 22: ...p meets the minimum heightrequirementsspecifiedinDia 4orlocal codes Note that for steep roof pitches the vertical height must be increased A poor draft or down drafting can result from high wind conditions near big trees or adjoining roof lines in these cases increasing the flue height may solve the problem 7 Ensure flue is vertical and secure the base of the flashing to the roof with roofing rail...

Страница 23: ...e the valve is in the OFF position 2 Loosen the IN 3 and or OUT 4 pressure tap s turning counterclockwise with a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pressure tap s using a 5 16 ID hose 4 Seal and or check the pilot outlet 8 5 The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label 6 When fini...

Страница 24: ...er 10 Open the bottom louver 15 Carefully pull out the control box 16 Remove the heat shield from the control box by removing the 2 screws Note The control box is held in place with velcro screw module cover connector orange connector wires control box heat shield PG33 Conversion Kit 433 968 from NG to LPG THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION...

Страница 25: ...nch Note The outlet pressure must be set to maximum 2 61 kPa Minimum pressure Remove one of the cables connected to the electric modulator Keeping the nut B blocked screw in the screw C to increase the pressure and screw it out to decrease it Use a screwdriver 6 x 1 blade Note The outlet pressure must be set to minimum 0 70 kPa After carrying out all adjustments block the setting screws with paint...

Страница 26: ...ss Log 902 253 D 251 Rear Left Log 902 251 Notch Bracket Bracket 250 254 Vermiculite Vermiculite Vermiculite 250 254 The 3 digit numbers i e 250 are molded into the rear of each log E 252 Front Right Cross Log 902 252 F Embers 902 156 G Vermiculite 902 179 21 H Rockwool 902 153 NOTE If you will be installing the optional Brick Panels install the Brick Panels prior to installing the logs 1 Carefull...

Страница 27: ...ith 1 screw as per diagram 2 Note Top and bottom louvers are different 5th Grate Tab 6 Place the bottom left front edge of Log 251 against the left edge of the burner tray and rest the log on the cutout on Log 253 7 PositionLog252acrossthecutoutsin Logs 254 and 253 The notch in the bottom right end fitting against the 5th grate tab 8 Pull off ember size pieces of rockwool and gently place them on ...

Страница 28: ...mes with a black frame To install the frame simply hook the top door flange onto the top of the unit and swing the door towards the unit diagram 1 Be care ful that the glass gasket does not roll up there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit Diagram 2 ...

Страница 29: ...ic ing controls Wiring errors can cause improper and dangerous operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut o...

Страница 30: ...G PLATE INSTRUCTIONS WARNING DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IN OPERATION Part 918 332a for ECS units except for FG38 Colours Black on Grey except for parts indicated as being Red Size 100 Feb 8 06 Changed AG 601 to AS5601 2004 as per Paul Watters ...

Страница 31: ...nds and the pilot sparks can be heard and seen It would take 2 to 3 seconds for the flame to be lit REMOTE CONTROL Use the Regency Remote Control Kit approved for this unit Use of other systems may void your warranty The remote control kit comes with a hand held transmitter and a wall mounting plate 1 Choose a convenient location to mount the hand held transmitter protection from extreme heat is v...

Страница 32: ...sixflamesettingsthatcanbeadjusted bypressingandreleasingtheplus and minus FLAME button The FLAME setting button is located on the control panel in behind the pedestal door SUMMARY OF CONTROLS On Off Button Iftheunit isswitchedoff pressingandreleasing this button once will switch the unit on The unit will resume its last settings If the unit is switched on pressing and releasing this button once wi...

Страница 33: ...r servicing WARNING CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEYAREINTHESAMEROOMAS THE APPLIANCE General Flue Maintenance Conduct an inspection of the flueing system semi annually Recommendedareastoinspectasfollows 1 ChecktheFlueingSystemforcorrosioni...

Страница 34: ...ARNING Donotoperatetheappli ancewiththeglasspanelsremoved cracked or broken Replacement of theglass panelsshouldbedonebya licensedorqualifiedserviceperson Caution Wear gloves when remov ing damaged or broken glass Flush Glass Replacement Remove the flush door front Remove the 4 glass clips from each corner Slide in the new replacement glass Push the 4 glass clips back onto the frame The glass must...

Страница 35: ...or and carefully pull out the ECS box 6 Remove the electric cover by undoing the 2 screws pull out the grommet and the harness 7 Unplug the black wire from the resister 8 Carefully slide the fan to the front left side of the unit 9 Remove the screw which holds the ground wire and disconnect all electrical connectors that are attached to the fan ECS Box 6 Pin Molex Connector 10 Pull out the fan Ele...

Страница 36: ...moving the 2 screws Rear Log Stand 7 Disconnect the inlet gas line 8 Remove the 10 Philips screws which secure the valve tray assembly 9 Unplug the 2 orange wires from the Gas Pressure Electric Modulator 10 Unplug the 5 pin Molex Connector from the valve 11 Unplug the ignitor and flame cables from the module and then lift the entire valve tray assembly out 5 Pin Molex Connector Module 2 Orange Wir...

Страница 37: ...me Cable N A N A N A N A N A N A N A N A 910 088 Spark Cable N A N A N A N A N A N A N A N A 910 084 Control Box N A N A N A 911 101 Control Box N A N A N A N A N A N A 910 527 Manual Control Switch N A N A N A N A N A N A 910 080 Valve 910 521 Control Box Cable 1 910 522 Control Box Cable 2 910 523 Control Box Cable 3 910 525 Control Box Cable 4 N A 2 1 1 3 N A 2 N A N A 910 912 Ignition Module t...

Страница 38: ... Mounting Plate 432 901 Brick Panel Set Standard Brown 432 902 Brick Panel Set Standard Red 432 903 Brick Panel Set Herringbone Brown 33 Brick Panel Rear 34 Brick Panel Left Side 35 Brick Panel Right Side 36 Brick Panel Top 37 430 056 Brick Clip Top 38 430 057 Brick Clip Bottom 89 946 004 Junction Box 90 946 000 Round Duct Adaptor 91 946 002 Round to Oval Adaptor 92 946 001 Oval Duct Adaptor 93 94...

Страница 39: ...0 Valve Tray 66 910 936 Pilot Assembly NG 904 568 Orifice 44 NG 904 163 Orifice 54 LPG 904 575 Orifice 55 ULPG 936 170 Orifice Gasket 67 Pilot Holder 68 W840470 Pilot Assembly Gasket 79 433 525 Burner Assy NG LPG 82 433 024 Burner Grate Assembly NG LPG 83 Rear Log Support Bracket NG LPG 85 431 930 Log Set 86 430 097 Air Deflector Left 87 433 018 Air Deflector Right Not available as a replacement p...

Страница 40: ...lack Steel Option 133 Flush Louver Assy Top 430 162 Front Deflector 134 Flush Louver Assy Bottom 433 538 Flush Door Assembly Complete 135 940 088 P Glass Flush 137 904 691 U Clip 139 936 155 Glass Gasket Tadpole 140 948 042 Spring Hinge Black 430 940 Finishing Trim Set Black Option 157 Finishing Trim Left 159 Finishing Trim Right 158 Finishing Trim Top 179 948 216 Regency Logo Plate Not available ...

Страница 41: ...components Ignition Control Boards Wiring Switches Fans Fan Control Module Battery Pack Remote Control Systems 1 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Fire beads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 After the original warranty coverage for any of the parts abo...

Страница 42: ...general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect If a consumer has a unit installed outside an accredited distributor dealer or pre approved service agent s service area or the closest approved service agent is situated more than thirty 30 kilometres from the inst...

Страница 43: ... movement expansion and contraction of the steel is normal and is not covered under the terms of this warranty Freight damages for products or parts are not covered under the terms of the warranty Porcelain Enamel Absolute perfection is neither guaranteed nor commercially possible Any chips must be reported and inspected by the authorised selling dealer within three 3 days of installation Any dama...

Страница 44: ...to at the option of the supplier one or more of the following i replacement of the goods or the supply of equivalent goods ii the repair of the goods iii the payment of the cost of replacing the goods or of acquiring equivalent goods or iv equivalent goods or v the payment of the cost of having the goods repaired b To the extent that services supplied by the supplier are services other than servic...

Страница 45: ...ervices Fireplace Products Australia Pty Ltd 1 3 Conquest Way Hallam VIC Australia 3803 Phone 61 3 9799 7277 Fax 61 3 9799 7822 To obtain warranty service in Western Australia and or New Zealand please contact one of our authorised distributors in those areas Western Australia Air Group Australia 28 30 Division St Welshpool WA Australia 6106 Phone 08 9350 2200 Fax 08 9353 4225 New Zealand Aber Hol...

Страница 46: ... in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases m...

Страница 47: ......

Страница 48: ...__________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ ...

Отзывы: