Regency PG33NG4-R Gas Inbuilt
19
installation
Horizontal Flueing with Three (3) 90
o
Elbows
Option V
H V + V1 H + H1
Min. Max. Min. Max.
A)
0.6m 0.3m 0.9m 1.2m
B) 0.9m 0.6m 1.2m 1.5m
C) 1.2m 0.9m 1.8m 1.8m
D) 1.5m 1.2m 2.4m 2.1m
E) 1.8m 1.5m 3m
2.4m
F)
2.1m 1.8m 3.65m 2.7m
With these options,
max. total pipe length
is 30 feet with min. of
12 feet total vertical
and max. 9 feet total
horizontal.
Please note min. 1
foot between 90
o
elbows is required.
Vertical Flueing with Two (2) 90
o
Elbows
Option V
H
V + V1
Min. Max. Min
A) 0.3m 1.2m 0.6m
B) 0.6m
1.5m 0.9m
C) 0.9m 1.8m 1.2m
D) 1.2m 2.1m 1.5m
E) 1.5m 2.4m 1.8m
Vertical Flueing with Two (2) 90
o
Elbows
With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and max.
8 feet total horizontal.
Please note min. 1 foot
between 90
o
elbows is re-
quired.
Option H + H1 V
Max. Min.
A)
0.6m 0.6m
B) 0.9m 0.9m
C) 1.2m 1.2m
D) 1.5m 1.5m
E) 1.8m 1.8m
With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and max.
6 feet total horizontal.
Please note min. 1 foot
between 90
o
elbows is
required.
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.
For additional vertical flueing with
2 x 90
o
elbows, refer to page 15.
Содержание Panorama PG33LPG4-R