52
|
Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace
|
52
maintenance
Electronic Modulator
REMOVING VALVE
1)
Shut off the gas and electrical supply.
2)
Remove the safety screen.
3)
Open and remove the glass door.
4)
Remove the logs.
5)
Remove the burner/grate assembly by removing the two screws
and then lift the burner assembly out.
Diagram 1: Remove the left and right screws and then lift out the
burner/grate assembly.
Diagram 2: Rear Log Stand & Valve Tray Assembly
Rear Log Stand
screws
INSTALLING VALVE
1)
Install new valve assembly.
2) Reverse steps 9 through 1.
Diagram 3: Lift out Valve Tray Assembly
9)
Remove the 10 screws securing the valve tray assembly in place
(diagram 2) and then lift the entire assembly out (diagram 3).
EV1
EV2
Ground
10)
Remove valve tray assembly.
6)
Disconnect the Electronic modulator, EV1, EV2, and ground wires
from the valve - as shown below.