Regency
®
P33-10 Zero Clearance Direct Vent Gas Fireplace
|
39
|
39
installation
OPTIONAL WALL THERMOSTAT INSTALLATION
A wall thermostat may be installed if desired.
Recommended: The wall thermostat should be mounted beside the Remote/Unit Receiver which comes standard with the appliance.
1)
Run wires from thermostat into the unit using the appropriate wire gauge-see chart below.
Disconnect greenTH wire
Green Wires
White Connector
3)
Connect one thermostat lead to female connector, using male spade con-
nector - see picture below.
CAUTION
Do not wire
Thermostat wires
to 120V wire.
4)
Connect the other thermostat lead to male connector disconnected
from Step1using a female spade connector - see picture below.
When complete turn remote receiver to the ON position.
Unit will now operate using the wall thermostat.
NOTE: When the remote receiver is set to ON position, the
remote control transmitter and all of its features are now dis-
abled.
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
50 Ft.
16 GA.
32 Ft.
18 GA.
20 Ft.
20 GA.
12 Ft.
22 GA.
9 Ft.
2) Remove the green wire marked (TH) at the white connector-shown
below. The noted wires will be located near the gas valve.