34
|
Regency
®
P33-10 Zero Clearance Direct Vent Gas Fireplace
|
34
installation
CONVERSION FROM NG TO LP
For P33-10 Using SIT 829 NOVA Gas Valve
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
1
10.17.14
919-466
Each Kit contains one LP
Conversion Kit
LP Conversion Kit Contains:
Qty. Part #
Description
1
904-575
Burner Orifice #55
1
910-582
Stepper Motor
1
918-590
Decal "Converted to
LPG"
1
908-528
Red "LPG" label
1
904-529
5/32" Allen Key
1
910-037
LPG Injector
(Pilot Orifice)
1
919-466
Instruction Sheet
Conversion from NG to LPG
using SIT 829 NOVA Gas Valve
Remove the 2 screws, push Burner
Assembly to the left and lift out.
Installation of the LPG
Conversion Kit:
1.
Shut off the gas and electrical supply.
2.
a) Remove the faceplate if installed.
b) Remove the safety screen and glass
door- see manual for detailed instruc-
tions.
c) Remove the logs, embers, and brick
panels (if installed).
d) Remove the 2 screws holding the
Burner Assembly to the firebox base.
Push the Burner Assembly to the left
and lift out.
4.
Unscrew the pilot orifice with the Allen
key and replace with the LP pilot orifice
in the kit and replace pilot cap.
3.
Remove pilot clip below pilot cap.
5.
Remove burner orifice with a 1/2"
wrench and discard. Use another wrench
to hold on to the elbow behind
the orifice.
Burner Orifice
6
.
Reinstall new burner orifice LPG
stamped #55 and tighten.
Clip
Pilot Cap
P33
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION!!
7.
Remove NG stepper motor by removing
3 screws in locations shown below–re-
place with LP stepper motor, secure in
place with 3 screws.
Remove NG Stepper motor and
replace with LP Stepper motor
Installer Notice:
These instructions must be left
with the appliance.
8.
Check for gas leaks with a proper soapy
solution or leak detector.
9.
Check for proper spark between the
ignitor and pilot cap. Refer to "Lighting
Procedure" section of the manual for
lighting sequence.
10.
Check pilot flames. Correct flame pattern
has 3 strong blue flames. Adjustment
can be made by turning the slotted
screw at the top right corner of the
valve. Refer to "Maintenance Instruc-
tions" section of the manual for correct
flame patterns.
11.
Check inlet and outlet pressures. Refer
to "Gas Pipe Pressure Testing" section
of the manual.
12.
Reverse Steps 3 to 1.
13.
Attach the label "This unit has been
converted to LP" near or on top of the
serial # decal.
14.
Replace yellow "NG" label with red "LP"
label.
15.
Check operation of flame control.
16.
Check for proper flame appearance and
glow on logs.