P33-10 Zero Clearance Direct Vent Gas Fireplace
|
11
|
11
installation
Clearances for Vignette Faceplate
The clearances listed below are Minimum
distances unless otherwise stated:
A major cause of chimney related fires is
failure to maintain
required clearances (air space) to combus
-
tible materials.
It is of the greatest importance that this
fireplace and vent system
be installed only in accordance with these
instructions.
Clearance to Combustibles from:
Back
0" (0mm)
Side
0" (0mm)
Floor
0"
(0mm)
NOTE: The minimum floor clearance must be
maintained
from the top surface of the carpeting, tile,
etc.
CLEARANCES WITH VIGNETTE FACEPLATE
Minimum Clearance from Top of Unit to:
Mantel*
min. 10" (254mm)
Ceiling
30"
(762mm)
from top of unit.
Side Wall Clearance 7-1/2" (191mm)
Minimum Vent Clearances:
2-1/2" (64mm) Horizontal Top
1-1/2" (38mm) Horizontal Side
1-1/2" (38mm) Horizontal Bottom
1-1/4" (32mm) Vertical Vent Clearance
(Rigid Vent)
1-1/2" (38mm) Vertical Vent Clearance
(Flex Vent)
Alcove Clearances:
Max. Depth
36" (914mm)
Min. Width
48" (1219mm)
Min. Height
59" (1499mm)
* see mantel clearance instructions.
Warning
Fire hazard is an extreme risk if these
clearances are not adhered to.
MANTEL LEG CLEARANCES WITH FLUSH GLASS
Combustible mantel leg clearances from side of unit as per diagram:
Maximum
1-1/2" projection at 2" minimum
clearance.