P33-10 Zero Clearance Direct Vent Gas Fireplace
|
14
installation
6)
Use steel studs for framing where the
1-1/2" (38mm) clearance from the vent
to combustible material cannot be
maintained.
16-1/2”
(419mm)
Minimum
4"
(102mm)
3"
(76mm)
1-1/2"
(38mm)
30”
(762mm)
10" (254mm)
dia. Hole through
wall for Dura-Vent
1/2"
(13mm)
Drywall
Top Header
Opening for gas
connection
12-3/4”
(324mm)
Minimum
4"
(102mm)
3"
(76mm)
1-1/2"
(38mm)
26”
(660mm)
10" (254mm)
dia. Hole through
wall for Flex
1/2"
(13mm)
Drywall
Top Header
Opening for gas
connection
Rigid Vent
Minimum Clearances
Flex Vent
Minimum Clearances
The
HeatWave
Duct Kit has different
clearance and framing requirements,
check the
HeatWave
manual for details.
Vi Vignette Finishing Trim
Flush Finished
Safety Screen and Optional Louvers
+ Vignette Only
Non- combustible