Regency
®
P36-5 Gas Log Fireplace
29
OPERATING INSTRUCTIONS
3)
Check for evidences of excessive
condensation, such as water droplets forming
in the inner liner, and subsequently dripping
out the joints, Continuous condensation can
cause corrosion of caps, pipe, and
fi
ttings.
It may be caused by having excessive
lateral runs, too many elbows, and exterior
portions of the system being exposed to
cold weather.
4)
Inspect joints, to verify that no pipe
sections or
fi
ttings have been disturbed,
and consequently loosened. Also check
mechanical supports such as Wall Straps,
or plumbers' tape for rigidity.
GOLD-PLATED &
BRASS
LOUVRES OR TRIM
The 24 carat gold plated or brass
fi
nish on the
trim requires little maintenance, and need only
be cleaned with a damp cloth. DO NOT use
abrasive materials or chemical cleaners, as
they may harm the
fi
nish and void the warranty.
Clean any
fi
ngerprints off before turning the
unit on. If the top louvres start to discolour,
check the door gasket seal and replace if
necessary.
LOG REPLACEMENT
The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door and carefully remove the
logs. (The pilot light generates enough heat to
burn someone.) If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagrams under Log
Installation.
Note: Improper positioning of logs may
create carbon build-up and will
severely alter the unit's performance
which is not covered under
warranty.
THERMOPILE /
THERMOCOUPLE
1)
Open the bottom louvres.
2)
Loosen the thermocouple or thermopile with
a 7/16" spanner.
3)
Disconnect thermocouple by loosening
nut from the valve with a 9mm spanner.
Disconnect thermopile by loosening 2
screws marked TP on the valve.
4)
Drop the thermocouple or thermopile down
from the bracket and pull it out of the unit.
5)
Reinstall the new ones in reverse order.
GLASS GASKET
If the glass gasket requires replacement use
a tadpole glass gasket for the Flush Front (Part
# 936-155).
DOOR GLASS
Your Regency
®
fi
replace is supplied with high
temperature, 5 mm Neoceram ceramic glass that
will withstand the highest heat that your unit will
produce. If your glass requires cleaning, we
recommend using an approved glass cleaner
available at all authorized dealers. Do not use
abrasive materials. Do not clean the glass
when hot.
In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency
®
dealer only, and follow our step-by-
step instructions for replacement.
WARNING: Do not operate the
appliance with the glass panels
removed, cracked or broken.
Replacement of the glass panels
should be done by a licensed or
quali
fi
ed service person.
Caution: Wear gloves when
removing damaged or broken
glass.
Flush Glass Replacement
Remove the
fl
ush door front (as per instructions
in section "Standard Flush Door"). Remove
the 4 glass clips from each corner. Slide in the
new replacement glass. Push the 4 glass clips
back onto the frame.
The glass must have
gasketing around it.