Regency
®
P36-5 Gas Log Fireplace
12
INSTALLATION
Simpson Dura-Vent
Co-Axial Flue GS
SIMPSON DURA-VENT FLUEING COMPONENTS LIST
All Simpson Dura-Vent components are available directly from Regency
®
.
Part # Description
Part # Description
Part # Description
SIMPSON DURA-VENT FLUEING
Horizontal or Vertical Terminations
The Simpson Dura-Vent Co Axial Flue System offers a complete line of component parts for installation of both horizontal and vertical installations.
Many items are offered in decorative black, as well as galvanized
fi
nish. We recommend using the galvanized
fi
nish for installation with the P36.
The minimum components required for a basic
horizontal termination are:
1 Horizontal
Termination
Cap
1 90
o
Elbow
1 Flue
Adaptor
1 Wall
Thimble
1 Length of pipe to suit wall thickness
(see
chart)
46DVA-06B 6" Pipe Length - Black
46DVA-09B 9" Pipe Length - Black
46DVA-12 12" Pipe Length - Galv.
46DVA-12B 12" Pipe Length - Black
46DVA-24 24" Pipe Length - Galv.
46DVA-24B 24" Pipe Length - Black
46DVA-36 36" Pipe Length - Galv.
46DVA-36B 36" Pipe Length - Black
46DVA-48 48" Pipe Length - Galv.
46DVA-48B 48" Pipe Length - Black
N/A 11"-14 5/8" Adjustable Pipe Length -
Black
N/A
17"- 24" Adjustable Length - Black
46DVA-E45 45
O
Elbow - Galv.
46DVA-E45B 45
O
Elbow - Black
Disc 45
O
Elbow - Swivel - Galv.
Disc 45
O
Elbow - Swivel - Black
46DVA-E90 90
O
Elbow - Galv.
46DVA-E90B 90
O
Elbow - Black
Disc 90
O
Elbow - Swivel - Galv.
Disc
90
O
Elbow - Swivel - Black
46DVA-VCH High Wind Termination Cap
(Vertical)
46DVA-VC Vertical Termination Cap
Disc Horizontal Square Termination
Cap
Disc. Horiz. Square High Wind
Termination Cap
46DVA-SNK14 Snorkel - 14" Rise Termination
Cap
N/A Snorkel - 36" Rise Termination Cap
46DVA-DC Wall Thimble - Support/Box
46DVA-CS Cathedral/Ceiling - Support/Box
46DVA-FS Firestop Spacer
46DVA-F6 Flashing 0/12-6/12
46DVA-F12 Flashing 7/12-12/12
46DVA-SC Storm Collar
46DVA-SC Vinyl Siding Standoff
46DNA-WT Wall Thimble
Parts not supplied by Dura-Vent
946-506/P
Flue Guard (Optional)
510-994 Dura-Vent
Flue
Adaptor
640-530/P Riser
Flue
Terminal
946-205 Vinyl
Siding Shield for Riser Flue
Terminal
If a Vinyl Siding Standoff is required (it must
be used with vinyl siding), measure to outside
surface of wall without siding and add 2
inches.
Flat Wall Installation
Wall Thickness
(mm)
Vent Length Required
(mm)
102 - 140mm
152mm
178 - 216mm
229mm
254 - 292mm
305mm
229 - 368mm
279 - 371mm Adj. Pipe
381 - 597mm
432 - 610mm Adj.
Corner Installation
Wall Thickness
(mm)
Vent Length Required
(mm)
83 - 171mm
279 - 371mm Adj. Pipe
197 - 413mm
432 - 610mm Adj. Pipe
184 - 222mm
152 + 305mm
229 + 229mm
108 - 146mm
152 + 229mm
Wall thickness is measured from the back
standoffs to the inside mounting surface of
termination cap. For siding other than vinyl furring
strips may be used, instead of the vinyl siding
standoff, to create a level surface to mount the
fl
ue terminal. The Terminal must not be recessed
into siding. Measure the wall thickness including
furring strips.