Regency
®
P36-5 Gas Log Fireplace
16
The P36 is approved for a 37 ft. (11.3m) straight vertical, with
Simpson
Dura-Vent Co Axial Flue GS
fl
ue systems for LPG and NG, as per the
diagram 3.
The shaded area in the diagram 3 shows all allowable combinations of
straight vertical and offset to vertical terminations with
Simpson Dura-
Vent Co Axial Flue GS
fl
ue systems for LPG and NG. Maximum two
45
o
elbows allowed.
• Flue must be supported at offsets
• Firestops are required at each
fl
oor level and whenever passing
through a wall.
• Maintain clearances to combustibles as listed in section
"Clearances."
Diagram 3
INSTALLATION