background image

Models: P36-NG5
 P36-LPG5

Owners &
Installation

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE 

REFERENCE

 

Manual

01/13/09

LISTINGS AND CODE APPROVALS

These gas appliances have been tested in 
accordance with AS4553-2000, NZS 5262 
and have been certi

fi

 ed by the Australian 

Gas Association for installation and 
operation as described in these Installation 
and Operating Instructions.

Your unit should be serviced annually 
by an authorised service person.

918-538b

WARNING:  
Improper installation, adjustment, alteration, 
service or maintenance can cause injury or 
property damage. Refer to this manual. For 
assistance or additional information consult 
an authorised installer, service agency or 
the gas supplier.

FOR YOUR SAFETY
Do not store or use gasoline or other 

fl

  ammable vapours and liquids in the vicinity 

of this or any other appliance.
Installation and service must be performed 
by an authorised installer, service agency or 
the gas supplier.

P36 GAS LOG FIREPLACE

FOR YOUR SAFETY
What to do if you smell gas:

 

Do not try to light any 
appliance

  Do not touch any electrical 

switch: do not use any 
phone in your building.

  Immediately call your gas 

supplier from a neighbour's 
phone. Follow the gas 
supplier's instructions.

  If you  cannot reach your 

gas supplier, call the 

fi

 re 

department.

Содержание P36-LPG5

Страница 1: ... cause injury or property damage Refer to this manual For assistanceoradditionalinformationconsult an authorised installer service agency or the gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flammablevapoursandliquidsinthevicinity of this or any other appliance Installation and service must be performed by an authorised installer service agency or the gas supplier P36 GAS LOG ...

Страница 2: ... warmth and charm of a wood fireplace at the flick of a switch The model P36 has been approved by the Australian Gas Association for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fir...

Страница 3: ...fety Information 5 Installation Checklist 5 Clearances 6 Locating Your Gas fireplace 6 Manufactured Mobile Home Additional Requirements 6 Combustible Mantels 7 Mantel Leg Clearances 8 Framing And Finishing 8 Unit Assembly Prior To Installation 9 Flueing Introduction 9 Exterior Flue Termination Locations 10 Flueing 11 Simpson Dura vent Flueing 12 Simpson Dura vent Flueing Components List 12 Flueing...

Страница 4: ... Gas Fireplace Wehaveprintedacopyofthecontents here for your review Australia Only Thelabelislocatedonthefrontinsidebaseofthe unit visible when the bottom louvre is open DATA BADGE NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one ...

Страница 5: ...NOT CONNECT TO MASONARY FLUE 4 This appliance must be connected to the specified flue and termination cap to the outside of the building envelope Never flue to another room or inside a building Make sure that the flue is fitted as per Flueing instructions 5 Inspect the flueing system annually for blockage and any signs of deterioration 6 Flueing terminals shall not be recessed into a wall or sidin...

Страница 6: ... e g wood metal concrete Thismaybethefloor orraisedup on a platform to enhance its visual impact If the appliance is going to be installed on carpeting combustible linoleum tile or other combustible material other than wood flooring the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance 4 The P36 Co Axial Flue Gas Fireplace can be installed in ...

Страница 7: ...tible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board COMBUSTIBLE MANTELS These drawings are to scale at 1 6 one inch 6 inches Mantel can be installed anywhere in shaded area or higher using the above scale Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour Diagram 1 INSTA...

Страница 8: ... the enclosure to the same degree as the rest of the house apply vapour barrier and drywall as per local installation codes Do not insulate the fireplace itself 4 The top of the unit must not be closer than 32 813mm to the ceiling 2 Frame in the enclosure for the unit with framing material Install Side Nailing Strips Top Facing Support and Top Standoffs before unit is slipped into position See Uni...

Страница 9: ...ort is reversed 1 Mount Top Facing Support using the 3 supplied screws into the three pre punched screw holes on the top front of the unit Use hole positions A B or C depending on your facing depth 2 Use the same screw hole position for the Side Nailing Strips as was used for the Top Facing Support Attach each side nailing strip using 3 screws INSTALLATION Beforetheunitisslidintoposition installth...

Страница 10: ...l air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I Appliances up to 150 MJ h input 500 Appliances over 150 MJ h input 1500 k Vertically below an openable window door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I see table below NOTES I For mechanical air inlets i...

Страница 11: ...crews 8 9 screws 8 x 1 1 2 Drill Point Stainless Steel 4 If longer runs are needed the Regency Direct Vent system Flex 946 516 includes all the parts needed to install the P36 with a maximum 3 0m run 1 175mm dia flexible liner 3 0m length 2 100mm dia flexible liner 3 0m length 3 spring spacers 7 4 thimble 2 5 AstroCap termination cap 1 6 screws 12 7 tube of Mill Pac 1 8 plated screws 8 9 screws 8 ...

Страница 12: ...O Elbow Black Disc 90O Elbow Swivel Galv Disc 90O Elbow Swivel Black 46DVA VCH High Wind Termination Cap Vertical 46DVA VC Vertical Termination Cap Disc Horizontal Square Termination Cap Disc Horiz Square High Wind Termination Cap 46DVA SNK14 Snorkel 14 Rise Termination Cap N A Snorkel 36 Rise Termination Cap 46DVA DC Wall Thimble Support Box 46DVA CS Cathedral Ceiling Support Box 46DVA FS Firesto...

Страница 13: ... 994 when using Simpson Dura Vent pipe Simpson Dura Vent 4 102mm inner diameter 6 5 8 168mm outer diameter Regency Flex Vent 4 102mm inner diameter 6 7 8 175mm outer diameter Maintain clearances to combustibles as listed in section Clearances Horizontal flue must be supported every 3 feet 0 9 meters Firestops are required at each floor level and whenever passing through a wall Aflueguardshouldbeus...

Страница 14: ...t 0 6m 4 Determine the permitted range of horizontal termination arrangements by using chart in section Simpson Dura vent Flueing and deducting 3 ft 0 9m from the maximum horizontal distance for the second 90o elbow Simpson Dura Vent 4 inner diameter 6 5 8 outer diameter Maintain clearances to combustibles as listed in section Clearances Horizontal flue must be supported every 3 feet 0 9 meters Fi...

Страница 15: ...nd NG as per diagram 1 The P36 is approved for a 37 ft 11 3m straight vertical including a 20 0 5m horizontal offset using two 90o elbow two 45o elbows equal one 90o elbow with Simpson Dura Vent Co Axial Flue GS flue systems for LPG and NG as per the diagram 2 Flue must be supported at offsets Maintain clearances to combustibles as listed in section Clearances Note Must use optional flue adapter w...

Страница 16: ... diagram 3 shows all allowable combinations of straight vertical and offset to vertical terminations with Simpson Dura Vent Co Axial Flue GS flue systems for LPG and NG Maximum two 45o elbows allowed Flue must be supported at offsets Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustibles as listed in section Clearances Diagram 3 INSTALLAT...

Страница 17: ...acent pipes and fittings by orienting the four pipe indentations so they match and slide in to the four entry slots on the male ends Diagram1 Pushthepipesections completely together then twist lock one section clockwise approximately one quarter turn until the two sections are fully locked The female locking lugs will not be visible from the outside on the Black Pipe or fittings They may be locate...

Страница 18: ...bob from the roof to the hole previouslydrilled in the ceiling and mark the s p o t w h e r e the flue will penetrate the roof Determine if ceiling joists roof rafters or other framing 3 A Firestop spacer must be installed in the floor or ceiling of every level To install the Firestop spacer in a flat ceiling or wall cut a 10 inch square hole Frame the hole as shown in Diagram 3 and install the fi...

Страница 19: ...wise until snug do not overtighten 12 Inserta5 32 or4mmAllen wrenchintothehexagonal key way of the screw Fig 2 rotate it counter clockwiseuntilitisfreeand extract it 13 Check that the screw is clean and if necessary remove dirt Conversion Kit Contains Qty Part Description 1 910 037 LPG Injector Pilot Orifice 1 904 390 Burner Orifice 52 1 918 590 Decal Converted to LPG 1 908 528 Red LPG label 1 904...

Страница 20: ...it does not have to be touching the burner Note Ifyouhaveanincorrectflamepattern contact your Regency dealer for further instructions Incorrect flame pattern will have small probably yellow flames not coming into proper contact with the rear burner or thermopile or thermocouple AERATION ADJUSTMENT The air shutter can be adjusted by moving the adjusting wire up or down The wire is accessed through ...

Страница 21: ...ext Slide them in from the front and push them flat up against the wall Be very careful not to scratch them on the firebox hardware 4 Install the 2 brick retaining clips one on each side LOG SET INSTALLATION Read the instructions below carefully and refer to the diagrams If logs are broken do not use the unit until they are replaced Broken logs can interfere with the pilot operation The gas log ki...

Страница 22: ... 49 02 51 02 53 02 55 02 53 02 50 02 55 02 53 02 50 02 55 02 53 02 49 02 51 02 53 02 51 02 54 Notch Bracket Bracket 02 49 02 51 02 49 02 51 4 Place Log 02 51 on the front right side of the burner Push the back of the log against the 2 brackets with the notch on the bottom right side of the log fitting into the right side of the grate 6 Place the bottom left front edge of Log 02 55 against the rear...

Страница 23: ...tach trim to the top and bottom of Flush door Flush Louvres Premium Flush Front 1 Install the top louvre by sliding the two bracket clips into the brackets located underneath the top of the firebox 2 The bottom louvre has a hinge that is attached 2 screws per hinge to the lip on bottom of the unit Note Top and bottom louvres are different 10 Place the embers on the front of the burner tray in the ...

Страница 24: ...hermostat wires for gas appliance to a 240V power supply Option 2 REMOTE CONTROL UsetheRegency RemoteControlKit approved for this unit Use of other systems may void your warranty The remote control kit comes with a hand held transmitter a receiver and a wall mounting plate 1 Choose a convenient location on the wall to install the receiver and the receptacle box protection from extreme heat is very...

Страница 25: ...N Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation This heater does not require a 240VA C supply forthegascontroltooperate A240VA C power supply is needed for the fan blower operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges Note If the optional premium flush front is used the fa...

Страница 26: ... turned off and on again without a minimum of a 60 second wait FAN 240 Volt AC power is needed for the fan switch andblower Thefancanbehardwiredifdesired Aterminal block is provided on the left hand side of the unit A three wire power cord can also be used and plugged into a suitable receptacle Unit must be grounded at all times Do not cut the ground terminal off under any circumstances Note A 240...

Страница 27: ...e While the pilot flame is on it can make a very slight whisper sound Gas Control Valve As the gas control valve turns ON and OFF a dullclickingsoundmaybeaudible thisisnormal operation of a gas regulator or valve Unit Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling p...

Страница 28: ...and turn to OFF position CAUTION Hotwhileinoperation Donottouch SevereBurnsmayresult Due tohighsurfacetemperatureskeepchildren clothingandfurniture gasoline and other liquids having fammable vapors away Keep burner and control compartment clean See installation and operating instructions accompanyingappliance LIGHTINGINSTRUCTIONS A This appliance has a pilot which must be lighted by hand When ligh...

Страница 29: ...of logs may create carbon build up and will severely alter the unit s performance which is not covered under warranty THERMOPILE THERMOCOUPLE 1 Open the bottom louvres 2 Loosenthethermocoupleorthermopilewith a 7 16 spanner 3 Disconnect thermocouple by loosening nut from the valve with a 9mm spanner Disconnect thermopile by loosening 2 screws marked TP on the valve 4 Drop the thermocouple or thermo...

Страница 30: ...ground wire clip see Diagram 5 9 Lift the fan off the 2 mounting pins see Diagram 7 10 Bring the fan to the front of the unit by manuevering it out on an angle see Diagram 8 10 Remove thermodisc by sliding it out from the thermodisc bracket see Diagrams 9 10 12 If terminal wires need to be removed for servicing make note of locations before removing see Diagram 11 13 Reverse steps to reinstall 8 R...

Страница 31: ...affect the appliance performance 9 Reinstall the 10 hold down screws 10 Hook up the 2 TP and 2 TH wires to the appropriate connections on the valve 11 Reinstall the front log stand 12 Install Burner grate assembly 13 Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector Do not use open flame for leak testing 14 Fire up the unit temporarily 15 Check the ...

Страница 32: ...s 910 714 Power Cord 240 V 14 510 026 Hinge Bracket Left Right 15 948 253 Door Handle 17 Wire Holder Clip 20 510 033 Top Nailing Strip 21 510 064 Side Nailing Strip 22 510 153 Baffle Plate 23 510 011 Standoff Top 24 511 044 Standoff Side Back 27 Outer Flue Collar 28 Inner Flue Collar Assembly 30 Gasket for Flue Collar 31 Flue Mounting Plate 513 901 Brick Panel Set Standard Brown 513 902 Brick Pane...

Страница 33: ... I T 910 039 Pilot Assy LPG 3 way flame S I T 904 240 Orifice 37 NG Burner 904 390 Orifice 52 LPG Burner 910 036 Pilot Orifice NG 910 037 Pilot Orifice LPG 936 170 Orifice Gasket 67 Pilot Holder 68 W840470 Pilot Assembly Gasket 79 514 535 Burner Assy NG 82 511 030 Burner Grate Assy 84 Rear Log Support Assy 85 512 930 Log Set 86 910 386 Thermocouple 87 910 341 Thermopile 88 910 096 Pilot Hood 3 way...

Страница 34: ... Steel Black 138 Flush Louvre Assy Top 139 Flush Louvre Assy Btm 510 932 Flush Glass Trim Gold 2 Set 150 Flush Glass Trim Gold 904 196 Magnet 1 round 510 947 Flush Glass Trim Steel 2 Set 152 Flush Glass Trim Brass 904 196 Magnet 1 round 510 986 Finishing Trim 3 piece Black 510 909 Finishing Trim 3 piece Steel 510 910 Finishing Trim 4 piece Steel 157 Finishing Trim Left 158 Finishing Trim Top 159 F...

Страница 35: ...e 35 PARTS LIST PREMIUM FLUSH FRONT ASSEMBLY Part Description 516 946 Premium Flush Front Black 179 910 975 Thermodisc 180 Top Louver 181 Bottom Louver 182 Thermodisc Mounting Bracket 183 Spacers Not available as a replacement part ...

Страница 36: ...rvice agent or the closest approved service agent is situated more than twenty five 25 kilometres from the installation Australian Heating Distributors are not obliged to arrange warranty repairs and travel and or additional labour charges will apply Exclusions This limited Lifetime Warranty does not extend to or include paint door or glass gasketing or trim It does not cover installation and oper...