44
Regency
®
HZI234E Direct Vent Gas Insert
MAINTENANCE
1)
Shut off gas supply to unit
and unplug the
power source by disconnecting the batteries.
2)
Open the left and right side faceplate panels.
Contour/Contemporary or remove front low
profi le faceplate.
3)
Remove the bottom louver by pulling out.
4)
Disconnect the EV1, EV2, and ground wires
from the valve - as shown below.
5)
Remove the glass door.
a)
Pull off the left side spring hook that holds
the door in place. While holding the hook turn it
upside down and place it into the middle opening
on the top side mounting bracket. Repeat for
right side
.
b)
Swing the door out 45 degrees and lift up
and out.
6)
Remove the crystals.
7)
Remove panels, if installed.
8)
Lift out the bottom tray.
Spring Hook
Top Mounting Bracket
9)
Remove the burner by removing 3 screws.
10)
Slide burner forward and lift up and out.
11)
Remove 15 screws to remove valve assembly
tray.
VALVE ASSEMBLY REPLACEMENT
12)
Pull out Valve assembly tray.
13)
Disconnect the inlet gas line.
13)
Replace valve and gasket (if required).
EV1
EV2
Ground
14)
Reverse steps to reinstall.