background image

Regency

®

 HZI234E Direct Vent Gas Insert

41

MAINTENANCE

2)

  Remove the Termination Cap, and shine a 

fl ashlight down the Vent. Remove any bird 
nests, or other foreign material.

3)

  Check for evidences of excessive 

condensation, such as water droplets forming 
in the inner liner, and subsequently dripping 
out the joints. Continuous condensation can 
cause corrosion of caps, pipe, and fi ttings. 
It may be caused by having excessive 
lateral runs, too many elbows, and exterior 
portions of the system being exposed to 
cold weather.

4)

  Inspect joints to verify that no pipe 

sections or fi ttings have been disturbed, 
and consequently loosened. Also check 
mechanical supports such as Wall Straps, 
or plumbers' tape for rigidity.

GLASS GASKET

If the glass gasket requires replacement use  
a tadpole gasket for the Flush Front (Part # 
936-155).   

Top view of pilot fl ame

Incorrect fl ame pattern will have small, probably 
yellow fl ames, not coming into proper contact with 
the rear of the burner or thermopile. 

 

Never operate the appliance without the 
glass properly secured in place or with 
the door open.

7)

  Do not use this appliance if any part has been 

under water. Immediately call a qualifi ed 
service technician to inspect the appliance 
and to replace nay part of the control system 
and any gas control which has been under 
water.

8) 

Periodically check the pilot fl ames. Correct 
fl ame pattern has three strong blue fl ames: 1 
fl owing around the thermopile and 1 around 
the thermocouple, and 1 fl owing across the 
front of the burner.

Note:  If you have an incorrect fl ame pattern, 

contact your FPI dealer for further 
instructions.

6) 

Each time the appliance is lit, it may cause 
condensation and fog the glass.  This 
condensation and fog is normal and will 
disappear in a few minutes as the glass heats 
up.

WARNING:  CHILDREN AND ADULTS 
SHOULD BE ALERTED TO THE 
H A Z A R D S   O F   H I G H   S U R FA C E 
TEMPERATURE AND SHOULD STAY 
AWAY TO AVOID BURNS OR CLOTHING 
IGNITION.  YOUNG CHILDREN SHOULD 
BE CAREFULLY SUPERVISED WHEN 
THEY ARE IN THE SAME ROOM AS 
THE APPLIANCE.

CAUTION:  ANY SAFETY SCREEN OR 
GUARD REMOVED FOR SERVICING 
AN APPLIANCE MUST BE REPLACED 
P R I O R   T O   O P E R AT I N G   T H E 
APPLIANCE.

CLOTHING OR OTHER FLAMMABLE 
MATERIAL SHOULD NOT BE PLACED 
ON OR NEAR THE APPLIANCE.

MAINTENANCE 

INSTRUCTIONS

1)

  Always turn the gas valve to the off position 

before cleaning. For relighting, refer to 
lighting instructions. Keep the burner and 
control compartment clean by brushing and 
vacuuming at least once a year.

 

When cleaning the logs, use a clean soft 
paint brush as the logs are fragile and easily 
damaged.

2)

  Clean (never when unit is hot) appliance, 

door and louvers with a damp cloth.  Never 
use an abrasive cleaner. The fi nishes  on 
louvers and doors may be scratched if 
abrasives are used to clean them. The 
heater is fi nished in a heat resistant paint 
and should only be refi nished with heat 
resistant paint (not with wall paint). FPI uses 
StoveBrite Paint - Metallic Black #6309.

3)

  Make a  periodic check of the burner for 

proper position and condition. Visually 
check the fl ame of the burner periodically, 
making sure the fl ames are steady: not 
lifting or fl oating. If there is a problem, call 
a qualifi ed service person. 

4)

  The appliance and venting system must be 

inspected before use, and at least annually, 
by a qualifi ed fi eld service person, to ensure 
that the fl ow of combustion and ventilation 
air is not obstructed. 

 

During the annual service call, the burners 
should be removed and cleaned from the 
burner tray. 

5)

  Keep the area near the appliance clear and 

free from combustible materials, gasoline 
and other fl ammable vapours and liquids.

Front Burner Tube

DOOR GLASS 

Your FPI insert is supplied with high temperature, 
5 mm Neoceram ceramic glass that will withstand 
the highest heat that your unit will produce.  Do 
not abuse the glass by striking the surface or 
by slamming the door shut.

If your glass requires cleaning, we recommend 
using an approved glass cleaner available at 
all authorized dealers. 

Do not use abrasive 

materials. Do not clean the glass when hot.

In the event that you break your glass by impact, 
purchase your replacement from an authorized 
FPI dealer only, do not use substitute materials 
(Regency Glass part # 940-355/P). Follow 
our step-by-step instructions for replacement. 

Warning: Wear gloves when removing 
damaged or broken glass.

Caution: Do not operate appliance with 
glass panels removed, cracked or broken. 
Replacement of the glass should be done 
by a licensed or qualifi ed service person.

GENERAL VENT 

MAINTENANCE

Conduct an inspection of the venting system 
semi-annually. Recommended areas to inspect 
as follows:

1)

  Check the Venting System for corrosion in 

areas that are exposed to the elements. 
These will appear as rust spots or streaks, and 
in extreme cases, holes. These components 
should be replaced immediately.

Burner

Flame Sensor

Pilot

Ignitor

Содержание HZI234E-LP

Страница 1: ...tion and service must be performed by an authorized installer service agency or the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire d...

Страница 2: ...ovide you with all the warmth and charm of a fireplace at the flick of a switch The HZI234E NG and HZI234E LP have been approved by Warnock Hersey for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features o...

Страница 3: ...r optional ceramic stones 20 Installation On Burner 20 Optional Pebble Crystal Installation 21 for Firebox Base 21 Reflective Panel Installation 22 Glass door Removal Installation 23 Optional Screen door Removal Installation 23 Low profile faceplate installation 24 3 and 4 sided 24 Contour Contemporary faceplate 26 Optional backing plate 29 Optional hearth Trim contour standard faceplate 31 Option...

Страница 4: ...ou d autres combustibles solides à moins que toutes les pièces d origine aient été remplacées et que le foyer ait été approuvé de nouveau par l autorité compétente WARNING AVERTISSEMENT Cet appareil d évacuation directe doit être installé selons les instructions du fabricant et conformément à la norme Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 ou les Standard of Fire...

Страница 5: ...ctly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspect...

Страница 6: ...mm 32 7 8 836mm 21 532mm 22 7 8 581mm 1 3 26mm 76mm 16 428mm 60 1 7 8 48mm 10 7 8 276mm 16 1 8 411mm 24 3 4 628mm 12 1 4 313mm 1 7 8 48mm 14 3 4 374mm 12 1 4 313mm 15 1 2 394mm with screwhead grommet for electrical cord 3 76mm 7 8 DIMENSIONS W LOW PROFILE 3 SIDED FACEPLATE ...

Страница 7: ...ILE 4 SIDED FACEPLATE 20 510mm 29 1 8 739mm 32 7 8 836mm 30 1 4 770mm 26 1 2 672mm 1 26mm 16 7 8 428mm 60 1 7 8 48mm 10 7 8 276mm 16 1 8 411mm 24 3 4 628mm 12 1 4 313mm 1 7 8 48mm 14 3 4 374mm 12 1 4 313mm 15 1 2 394mm with screwhead grommet for electrical cord 3 76mm 3 76mm ...

Страница 8: ...ceplate 27 3 4 705mm 27 1 2 699mm 19 1 2 495mm 13 330mm 11 3 4 299mm 14 3 4 375mm 24 3 4 629mm 3 76mm 2 1 2 64mm Contemporary Faceplate Contour Faceplate 19 1 2 495mm 21 533m m 15 5 8 381m m 15 5 8 381m m 16 7 8 429m m 16 1 4 413m m 20 3 4 527m m DIMENSIONS W CONTEMPORARY AND CONTOUR FACEPLATE ...

Страница 9: ... APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE YOUNG CHILDREN SHOULD BE CARE FULLY SUPERVISED WHENTHEY ARE IN THE SAME AREA AS THE APPLI ANCE TODDLERS YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENTAL CONTACT BURNS A PHYSICALBARRIERSISRECOMMEND ...

Страница 10: ...leanoutsmustfitproperly Refractory glass doors screen rails screen mesh and log grates can be removed from the fireplace beforeinstallingthegasfireplaceinsert Smoke shelves shields and baffles may be removed if attached by mechanical fasteners A tight seal between the gas fireplace insert flue collar and the fireplace chimney must be made to prevent heat loss Checkwithyourlocalinspectorbeforecomme...

Страница 11: ...ere applicable Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer birth defects or other reproductive harm a Reflective Panels brick panels b Glass Crystal Installation c Screen Door d Faceplate e Backing Plate f Remote Control g Wall Thermostat 10 Final check Refer to the Final Check section Before leaving this unit with the customer the in...

Страница 12: ...antel may be installed anywhere in the shaded area or higher Note A non combustible mantel may be installed at a lower height Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour D E F A B C 56 to ceiling 15 5 8 397mm to floor 12 Mantel 1 Mantel 4 Mantel 24 1 2 Top of Door Frame 15 1 2 17 1 2 22 24 Unless otherwise stated the clearances liste...

Страница 13: ...nt can only be used with 3 and 3 liners INSTALLATION WITH 3 3 LINERS Part Description 948 305 3 Flex 35 ft intake exhaust 946 529 FPI Co linear DV Vertical Termination Cap Flashing The HZI234E is also approved for use with a 2 liner for air intake and a 3 liner for exhaust This would be suitable for a Class A wood burning chimney with a minimum 6 round flue The chimney must be lined with one 2 dia...

Страница 14: ...e the 4 screws that hold the vent restrictor plate in place 2 Remove the 3 collar from the top plate by undoing the 4 screws NOTE The screws are secured from the underside of the top plate Underside of Top Plate 3 Secure the 2 collar to the top plate using 4 screws in place of the 3 collar 4 Re install the top plate to the unit Top Plate with 2 Collar shown on Unit 4 Adjust the vent restrictor pla...

Страница 15: ...E seal connection with high temperature silicone Secure with gear clamp or screws NOTE 1 Final gas connection should be made after unit is in place to avoid damage to the liner when pushing the unit into position 2 Mill pac may be used instead of high temperature silicone and screws may be used instead of gear clamps at connections of liner to inlet and vent collars 9 Connect the 2nd liner to the ...

Страница 16: ... the CAN CGA B149 installation code For USA installations follow local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be easily disconnected for servicing Flare nuts for copper lines and flex connectors are usually considered to meet this requirement NOTE A shutoff dante valve ...

Страница 17: ...assembly 3 With Burner Assembly removed lift out firebox base 9 Proceed to section B Firebox base 1 Unplug the power source and shut off gas supply 2 Open the left and right side faceplate panels 3 Remove the bottom louver by pulling out 4 Remove the glass door a Pull off the left side spring hook that holds the door in place While holding the hook turn it upside down and place it into the middle ...

Страница 18: ... 13 Pull off the pilot cap to expose the pilot orifice 14 Unscrew the pilot orifice with the Allen key and replace with the LPG pilot orifice in the kit and replace pilot cap 15 Remove burner orifice with a 1 2 wrench and discard Use another wrench to hold on to the elbow below the orifice 1 Remove and discard 2 Pressure regulator screws A T20 or slot Pressure Regulator B Spring and Diaphragm C 2 ...

Страница 19: ...ow NG label with red LPG label 5 Adjust aeration setting on burner see aeration adjustment section in manual 6 P33SE 4 Reverse steps 4 1 on previous pages HZI234E Reverse steps 12 1 on previ ous pages 7 Check for gas leaks 8 Check inlet and outlet pressures 9 Check operation of flame control Installer Notice These instructions must be left with the appliance ...

Страница 20: ...0 spa stones PTO30 PlateauSeries 10 lbs Not Approved PTO60 20 lbs Not Approved U32S U32SE 1 lb 1 package 70 spa stones E33S 1 lb 1 package 70 spa stones NOTE Glass Crystals are available in 1lb and 5lb bags All units come standard with Cobalt Blue glass crystals except HZO42 comes with Copper glass crystals HZI390E HZI390EB HZI540EB PTO30 PTO60 Plateau Series do NOT include glass crystals with uni...

Страница 21: ... fireplaces Use of any other type of pebbles glass crystals or other material can create a danger and will void the warranty Glass Crystals shown surrounding the Burner Firebox Around Burner Packages Unit Glass Crystals Pebbles HZ54E HZ54EPV 6 lbs 2 packages 6 x bags pebbles HZ42 HZ42E HZ40E 5 lbs 2 packages 6 x bags pebbles HZ42ST HZ42STE HZ42STEPV 5 lbs 2 package 6 x bags pebbles HZ30E 2 lbs 1 p...

Страница 22: ...ll glass door reinstall faceplate 7 Final installation Before installation panels must be handled and cleaned as per instructions noted below Black Enamel Panels Black Enamel panels must be inspected for scratches and dimples prior to installation All claims to be recorded at this time Claims for damage after installation will not receive consideration Black Enamel panels will discolor a little du...

Страница 23: ...ting bracket Repeat for right side b Swing the door out 45 degrees and lift up and out 1 Remove the glass door 2 Hook the screen door over top of the glass door Spring Hook Screen Door Spring Hook Top Mounting Bracket 2 To install the door reverse steps 3 Install the screen door and glass door as one onto the unit a Pull off the left side spring hook from the top mounting bracket Place the spring ...

Страница 24: ...hen in position tighten screws 3 From the right side of the unit remove the on off switch box cover one screw top and bottom Connect the red female ON OFF valve connec tors to the ON OFF switch located on the right faceplate panel 4 Remove the battery pack holder from the right hand side faceplate 5 Peel off the tape from the velcro strips and Install batteries into the Battery Pack Holder batteri...

Страница 25: ...and corner of the front low profile faceplate Logo Bottom louver 9 Reattach the battery pack holder to the faceplate and ensure the loose wires are away from the side of the firebox 7 Connect the red black wires tagged battery 8 Install 4 AA batteries Do not connect a 9V battery 10 Connect the fan rheostat to the wires from the unit behind the left side of the backing plate as shown below NOTE Ens...

Страница 26: ...eft and right side panels to show keyhole mounting 2 Open the left and right side faceplate panels of the faceplate 3 Mount the faceplate onto the unit by aligning the 4 key hole slots in the faceplate with the screws installed to the mounting brackets on the unit Tighten screws to secure See diagram 2 Diagram 1 Diagram 2 5 From the right side of the unit connect the red female ON OFF valve connec...

Страница 27: ...eft side of the unit See diagram 7 6 Peel off the tape from the velcro strips and mount the battery pack to the velcro on the inside of the right faceplate panel as shown in diagram 5 Battery Pack Diagram 5 Diagram 6 Diagram 8 11 Tuck the wires completely into the sleeve and place the supplied cable tie to the end of it as shown in diagram 9 Diagram 9 12 Place the grommet removed from step 10 over...

Страница 28: ...Re install the remote receiver bracket reverse step 10 14 Close the left side faceplate panel 15 Fit the bottom louver into the slots at the bottom of the firebox as shown in diagram 12 Diagram 12 Completed Faceplate Installation Contemporary Faceplate Contour Faceplate ...

Страница 29: ...ng Plate Installation Customize Backing Plate The inside of the backing plate may be cut as required using a metal cutting blade Do not cut the outside edges TheBackingPlatecanbeadjustedtocustomfitaninstallationbytrimming the inside of the top corner and side pieces as shown in the diagram below The dotted lines shown are only an example of where you can cut Cuts can be made beyond these marks as ...

Страница 30: ... Right Corner Backing Plate 9 Place the right side corner backing plate over the top and right side backing plate Push in place to secure see diagram 5 Repeat for left side Completed Backing Plate Installation Faceplate shown on unit without left and right side panels to show keyhole mounting 5 Open the left and right side faceplate panels of the faceplate 6 Mount the faceplate onto the unit by al...

Страница 31: ...ounting of hearth trim a The Hearth Trim can be adjusted to custom fit an installation by pulling apart the top piece from the bottom piece b Cut the top of the bottom piece of the hearth trim to the appropriate height using a metal cutting blade NOTE The tab bends at the back of the top piece of the hearth trim should be used as the measuring point to the hearth to measure the height required c R...

Страница 32: ...tom piece b Cut the top of the bottom piece of the hearth trim to the appropriate height using a metal cutting blade NOTE The tab bends at the back of the top piece of the hearth trim should be used as the measuring point to the hearth to measure the height required c Reattach the top piece of the hearth trim to the cut bottom piece by fitting in place Top Piece Cut Here top of bottom piece Exampl...

Страница 33: ...and the battery pack wires 3 Pull wires back through opening Access white and green wires from wire harness Disconnect Red and Black from the Green and White wire 4 Install Remote Receiver into left side opening secure with two screws Holes are pre punched in frame Be sure arrow on receiver is point up 5 Feed the receiver end of the wire harness under the front edge of firebox from right to left G...

Страница 34: ... DFC supply wire black red 9 Connect the green wire TH to the green TH connect the white TH TP to white TH TP and finally connect the red black DFC supply to the red black DC supply wire The Remote receiver will now power the digital fireplace control board 10 Install batteries into the remote receiver program handheld to receiver following the installation instructions provided and then install t...

Страница 35: ... with the side access panel removed A wall thermostat may be installed if desired Recommended Mount thermostat beside unit receiver 1 Run wires from thermostat into the unit using the appropriate wire gauge see chart below 3 Connect one thermostat lead to female connector using male spade con nector see pic below 4 Connect one thermostat lead to male connector using female spade connector see pic ...

Страница 36: ...ction when servicing controls Wiring errors can cause improper and dangerous operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges Note 4 AA batteries must be installed to operate the burner switch Do not use a 9 volt battery IMPORTANT If the optional remote control is used the AA batteries normally installed into the battery holder must be removed The...

Страница 37: ... AC adaptor to the female end tagged DC Supply on wiring harness in unit 2 Locate FCM COM connector on the Remote wire harness see manual for location in unit 3 Plug in wire adaptor to FCM COM connector be careful not WR GDPDJH HQGV 7KLV RQO WV RQH ZD 3 Plug AC adaptor into 120V wall outlet or into 120V receptacle if LQVWDOOHG LQVLGH WKH JDV UHSODFH UHER 4 Neatly tuck any loose AC Power Adaptor wi...

Страница 38: ...IRING DIAGRAM CAUTION Labelallwirespriortodisconnection whenservicingcontrols Wiringerrorscancause improper and dangerous operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges Verify proper operation after servicing ...

Страница 39: ...s defects in your appliance Burner Tray The burner tray is positioned directly under the burner and is made of a different gauge material from the rest of the firebox and body Therefore the varyingthicknessesofsteelwillexpandandcontract at slightly different rates which can cause ticking and cracking sounds You should also be aware that as there are temperature changes within the unit these sounds...

Страница 40: ...n service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un incendie ou une explosion entraînant des dommages de...

Страница 41: ...ing For relighting refer to lighting instructions Keep the burner and control compartment clean by brushing and vacuuming at least once a year When cleaning the logs use a clean soft paintbrushasthelogsarefragileandeasily damaged 2 Clean never when unit is hot appliance door and louvers with a damp cloth Never use an abrasive cleaner The finishes on louvers and doors may be scratched if abrasives ...

Страница 42: ...ding the hook turn it upsidedownandplaceitintothemiddleopening on the top side mounting bracket Repeat for right side b Swing the door out 45 degrees and lift up and out 5 Remove the crystals 6 Remove panels if installed 7 Lift out the bottom tray Spring Hook Top Mounting Bracket 8 Remove the burner by removing 3 screws 9 Slide burner forward and lift up and out 10 Pull off the pilot hood cover 11...

Страница 43: ...3 screws to remove the fan access plate 14 Lift fan access plate up and out 15 Unplug fan access wires 16 Remove 2 screws holding the fan bracket in place 17 Remove the fan by sliding forward then lift the fan up and out 18 Remove the ground screw holding the ground wire 19 Reverse steps to install fan ...

Страница 44: ...at holds the door in place While holding the hook turn it upsidedownandplaceitintothemiddleopening on the top side mounting bracket Repeat for right side b Swing the door out 45 degrees and lift up and out 6 Remove the crystals 7 Remove panels if installed 8 Lift out the bottom tray Spring Hook Top Mounting Bracket 9 Remove the burner by removing 3 screws 10 Slide burner forward and lift up and ou...

Страница 45: ...ssy LP 9 904 241 Orifice 56 LP 10 904 622 Orifice 48 NG 11 904 658 Inlet flex gas line 12 910 142 Thermosdisc 13 910 215 P Fan 14 911 004 Valve NG 886 911 005 Valve LP 886 15 911 006 Pilot Assy NG 911 007 Pilot Assy LP 16 911 012 Ignition Board DBC 17 911 013 Wire harness 18 911 018 Battery Holder 19 940 355 P Neoceram Glass 20 946 678 Colbalt Fireglass 21 566 010 False Tray 22 566 908 Enamel Pane...

Страница 46: ...ription 1 566 924 3 sided low profile faceplate 2 566 024 3 sided low profile back plate 3 566 025 3 sided low profile front frame 4 566 926 4 sided low profile faceplate 5 4 sided low profile back plate 6 4 sided low profile front frame 7 566 030 Bottom louver 8 566 528 Optional screen door 4 5 6 7 3 2 1 8 ...

Страница 47: ... FACEPLATE ASSEMBLY Part Description 60 536 918 Contemporary Faceplate 61 536 914 Contour Faceplate 62 910 246 Burner ON OFF Switch 63 910 330 Fan Speed Control 120 V 64 904 569 Fan Speed Control Knob 65 536 125 Fan Switch Bracket 66 948 216 Regency Logo ...

Страница 48: ...Gas Insert PARTS LIST BACKING PLATE HEARTH TRIM ASSEMBLY Part Description 536 922 Backing Plate 81 Left Side 82 Right Side 83 Top 84 Left Corner 85 Right Corner 536 940 Hearth Trim 86 Top 87 Bottom Not available as a replacement part ...

Страница 49: ...Regency HZI234E Direct Vent Gas Insert 49 NOTES ...

Страница 50: ...50 Regency HZI234E Direct Vent Gas Insert NOTES ...

Страница 51: ...Transportation Prepaid if requested Porcelain Enamel Absolute perfectionisneither guaranteednor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced ...

Страница 52: ...__________________________________________________________ Phone ___________________________________________________________ Date Installed ______________________________________________________ Serial No __________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all y...

Отзывы: