WALL SWITCH
(Included with Unit)
1)
Run the supplied 10' of wire through the right
or left side gas inlet opening. Be careful not to
damage wire.
Note: We recommend a maximum of 10' of
wire but if you wish to go with a longer
run, use the Thermostat Wire Table.
2)
Connect the wire to the wall switch and install
into the receptacle box. Also attach wires to
the valve as shown below.
Optional
WALL THERMOSTAT
A wall thermostat may be installed if desired,
connect the wires as per the wiring diagram. Use
table below to determine the maximum wire length.
Note: Preferable if the thermostat is installed
on an interior wall.
Regency
®
offers an optional programmable
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.
Optional
REMOTE CONTROL
Use the Regency
®
Remote Control approved for this
unit. Use of other systems may void your warranty.
The remote control comes with a hand held transmit-
ter, a receiver and a wall mounting plate.
1)
Choose a convenient location on the wall to
install the receiver and the receptacle box
(protection from extreme heat is very important).
Run wires from the fi replace to that location.
Use Thermostat Wire Table.
GT /GTM REMOTE FEATURES
** GTMF NOT OFFERED ON THE HZ42E
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
50 Ft.
16 GA.
32 Ft.
18 GA.
20 Ft.
20 GA.
12 Ft.
22 GA.
9 Ft.
584 Proflame GT Series
Feature Sheet
(X)
Indicates Included Feature
Note 1 ~ Profl ame Flame Modulator for GTM & GTMF Remote Controls are sold seperately. Choice of NG or
LP fl ame modulator (to match unit fuel type). See Regency Retail Price pages for complete details
1
1
1
Note: Regency Profl ame systems include a white and black wall cover & switch.
**
CAUTION
Do not wire millivolt
wall thermostat wires
to 120V wire.