Regency GF1500L Gas Fireplace
29
installation
CONVERSION KIT FROM NG TO LP/ULPG
FOR GF1500L USING SIT 845 NOVA GAS VALVE
919-586
06/25/15
PRIOR TO CONVERSION, ENSURE UNIT HAS COOLED TO ROOM
TEMPERATURE, ALL POWER IS DISCONNECTED AND GAS SUPPLY
IS TURNED OFF.
1
. Remove faceplate, inner frame, glass door, front trim piece- see instruc-
tions in this manual.
2
. Remove logs.
3. Remove Inner panels
4
. Remove burner side panels by lifting out as shown in Diagram 1.
6.
Remove burner by removing 3 screws in locations shown below.
Diagram 2 - Burner Screw Locations
CONVERSION KIT FROM NG TO ULPG
FOR GF1500L USING SIT 845 NOVA GAS VALVE
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
5.
Remove rear log tray by removing 3 screws as shown in Diagram 3 below.
Each Kit contains one LP / ULPG
Conversion Kit
Qty.
Part #
Description
1
904-431
Burner Orifice#49 ULPG
1
904-434
Burner Orifice #47 LP
1
918-590
Decal “Converted to LP”
1
908-528
Red Propane Label
1
918-272
Conversion to ULPG decal
1
904-529
5/32” Allen Key
1
910-037
Injector Orifice LP #30
1
918-273
Red ULPG label
1
919-586
Instruction Sheet
Diagram 4 - Remove Pilot Cap
Pilot Cap
Pilot Orifice
7.
Pull off the pilot cap to expose the pilot orifice (see right).
8
.
Unscrew the pilot orifice with the Allen key and replace with the LP/
ULPG pilot orifice in the kit and replace pilot cap (see right).
9.
Remove burner orifice with a 12mm spanner and discard. Use
another spanner to hold on to the elbow below the orifice.
Diagram 1 - Burner Side Panels
IT WOULD BE BENEFICIAL TO CONVERT THE APPLIANCE PRIOR TO
THE UNIT BEING INSTALLED OR WALL FACING MATERIAL FITTED
WHICH ALLOWS ACCESS TO THE BOTTOM PANEL.
Diagram 3 - Rear Log Tray Screw Locations
1
GF1500L