18
Regency GF1500L Gas Fireplace
installation
Set 3-(32mm)
Set1-(44mm)
Set 2- (41mm)
FULLY OPEN
Set-0 (108mm)
FACTORY SETTING
Flue restriction is required for certain venting installations, see
the diagrams in the "Flueing
Arrangements" section to determine
if they are required for your installation.
The Flue Restrictor plate is located on the inside top of the firebox.
To set the flue restriction as indicated in the flueing arrangements
diagrams, refer to the following instructions;
1.
Remove the glass door and inner panels - see instructions
in this manual.
2.
Remove 6 screws (3 front - 3 back) to remove heat baffle to
access restrictor plate.
3.
Remove the screws that hold the flue restrictor in place.
FLUE RESTRICTOR SETTINGS
Heat Baffle
4.
Adjust the flue restrictor plate to the required flue restrictor
position as per the diagrams shown below.
5.
Once the flue restrictor plate is in the required position,
secure with screws.