installation
Grandview
®
G600C Gas Fireplace
|
49
The Diagrams show all allowable combinations of vent runs with 4" x 6-5/8" venting using the Regency direct vent system or rigid vent system.
A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.
For horizontal terminations the Regency Direct Vent Flex System may be used for installations with a maximum
continuous
vent maximum horizontal length
of 3ft (0.9m).
Note: Must use optional rigid pipe adaptor (Part # 510-994) when using Rigid Pipe vent systems.
• Maintain clearance to combustibles.
• Horizontal vent must be supported every 3 feet.
• Firestops are required at each floor level and whenever passing through a wall.
2
0
12
6
4
8
10
2
0
6
4
8
Vertical Height (Feet)
Rigid 39-1/2" (1.1 m)
Horizontal (Feet)
Max. 36” (0.9 m)
Flex 39-1/2" (1.1 m)
Set 2
Set 1
24" (0.61 m)
25”
(0.64 m)
Top Vented
Set #1 - 2" (51mm) open between 1-3' (0,3 - 0,91 m)horizontal
Set #2 - 1-3/4" (44mm) open less than 1' horizontal
Rear Vented
Factory Setting - 2-1/2" (64mm)
Venting Arrangements for Horizontal Terminations
- Flex Vent or Rigid Pipe 4" x 6-5/8" (102mm x 168mm)