30
|
Grandview
®
G600C Gas Fireplace
installation
Clean Front Installation (Non Cool Wall) - Mantel Clearances
Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the
Diagram on the right.
Note: Ensure the paint that is used on the mantel and the facing is "High Quality" or the paint may discolour.
Mantel Clearances
G600EC
A
B
C
D
From Top of Fireplace
Opening
28-3/8"
(721mm)
23"
(584mm)
19-1/4"
(489mm)
14"
(356mm)
Combustible
Mantel Clearances
0
5
10
0
Top of
Fireplace
Opening
12"
(305 mm)
5"
(127 mm)
17"
(432 mm)
A
B
15
To Floor
Inches
C
D
Non-Combustible Material
Min. 13" H (330mm)
5
10
20
15
1"
(25 mm)
Min.
25