40
Regency GF900C Gas Fireplace
MAINTENANCE
All maintenance must be carried out by a licensed qualified service person
IT IS CRITICAL THAT THIS APPLIANCE IS EARTHED AND THAT THE ACTIVE AND NEUTRAL ARE NOT REVERSED
UNIT OPERATION
ACTION REQUIRED
No gas to the burner
The gas valve should open at the same
ti
me the igni
ti
on commences sparking. If
there is no gas to the burner, turn unit o
ff
. Connect manometer to inlet test point
on the gas valve and check sta
ti
c pressure. If O.K. turn unit on and check there is
no signi
fi
cant drop in the pressure. If O.K. connect manometer to outlet test point
of the gas valve, turn unit on and check outlet pressure is present whilst the spark is
being generated.
Unit sparks, main burner ignites after 5 seconds
This can be caused by incorrect polarity.
spark continues even though main flame is present
Check that the wall socket to the appliance has correct polarity. If an extension lead
is
fitt
ed check polarity of the lead. Check the polarity of the supply lead to the
appliance. NOTE: The above checks must be carried out by a qualified person
Convection fan operates but no
Igni
ti
on module is in lockout, reset module.
ignition after approx 1 minute
Then turn on again.
NOTE: On initial light up this may occur a number of times until any residual air is
purged from the gas line through the burner system. It is essential the required
waiting time as stated in the manual is observed prior to attempting re ignition
After resetting ignition module, unit still not
Turn burner switch to "ON", fans will operate within 25 secs, listen for audible "click"
fi
rst from
operating after 1 minute
igni
ti
on module, then from pressure switch.
If no "click' heard contact service agent
Confirm spark is produced when heater is turned on
The igni
ti
on electrode should spark at the same
ti
me the gas control solenoid valve
opens(a
ft
er approx 1minute purge
ti
me). At this point the spark electrode will
ac
ti
vate for up to 5 seconds. A blue spark can be seen when the heater igni
ti
on
process starts, Ensure the spark is present between the electrode and burner.
If no spark is produced
Check the combus
ti
on fan & pressure switch are opera
ti
ng (there should be an
audible click when the pressure switch makes contact). Providing the spill switch
has con
ti
nuity the electrode should spark and the gas valve open within 5 seconds
of the comple
ti
on of the purge cycle.
GLASS DOOR INSTALLATION