MAINTENANCE
3)
Check for evidences of excessive condensa-
tion, such as water droplets forming in the
inner liner, and subsequently dripping out the
joints, Continuous condensation can cause
corrosion of caps, pipe, and fittings. It may
be caused by having excessive lateral runs,
too many elbows, and exterior portions of
the system being exposed to cold weather.
4)
Inspect joints, to verify that no pipe sections
or fittings have been disturbed, and conse-
quently loosened. Also check mechanical
supports such as Wall Straps, or plumbers'
tape for rigidity.
LOG REPLACEMENT
The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door and carefully remove the
logs. (The pilot light generates enough heat to
burn someone.) If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagrams under Log
Installation.
Note: Improper positioning of logs may cre-
ate carbon build-up and will severely
alter the unit's performance which is
not covered under warranty.
GLASS GASKET
If the glass gasket requires replacement use a
tadpole glass gasket (Part # 936-155).
DOOR GLASS
Your Regency fireplace is supplied with high
temperature 5mm-Tempered glass & 5mm-
Ceramic glass. If your glass requires cleaning,
we recommend using an approved glass cleaner
available at all authorized dealers. Do not use
abrasive materials.
CAUTION & WARNINGS:
* Do not clean when the glass is hot.
* The use of substitute glass will void all prod
uct warranties.
* Care must be taken to avoid breakage of
the glass.
* Do not strike or abuse the glass.
* Do not operate this fireplace without the
glass front or with a cracked or broken glass
front.
* Wear gloves when removing damaged or
broken glass.
* Replacement of the glass panels should be
done by a licensed or authorized service per
son.
GLASS REPLACEMENT
In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency dealer only. Replacement glass is
shipped already installed into the door frame.
REPLACEMENT PARTS:
Front Door - Tempered (Part# 360-528/P)
Side Door - Tempered (Part# 360-529/P)
Front Door - Ceramic (Part# 360-946)
Side Door - Ceramic (Part# 360-948)
GOLD-PLATED
ACCESSORIES
The 24 carat gold-plated finish requires little
maintenance, and need only be cleaned with a
damp cloth. DO NOT use abrasive materials or
chemical cleaners, as they may harm the finish
and void the warranty.
Clean any fingerprints
off before turning the unit on.
VALVE TRAY
REPLACEMENT
1) Shut off the gas supply.
2) Remove the louvers and trim kit. Remove
the front door.
3) Remove the logs, embers.
4) Remove the grate by lifting straight up.
5) Remove the side brick clip in the top of the
firebox and then slide the Side Brick Panel
out.
The brick panels are very fragile -