Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
25
INSTALLATION
LOG SET INSTALLATION
Read the instructions below carefully and refer to the
diagrams. If logs are broken do not use the unit until
they are replaced. Broken logs can interfere with the
pilot operation.
Log Kit # 360-930 contains the following pieces:
a) 326 Front Right Log
b) 327 Front Left Log
c) 328 Middle Right Log
d) 329 Middle Left Log
e)
Embers (902-154)
f)
Platinum Embers (946-669) -
supplied with pack-
aged manual
The 3-digit numbers (ie. 327) are molded into the rear of each log.
326
327
329
328
Please note that there are 2 of each log.
This log set is mirrored front and back.
326
Push back side of the left end of the log up
against the tab on the burner.
327
Grate Post
3)
Place Log 326 on the front right side of the burner.
Ensure that the notches on the far right side of the log
fi t into the grate posts. Push back side of the left end
of the log up against the tab on the burner.
Repeat step 3 on the opposite side of the burner.
4)
Place Log 327 on the front left side of the burner. Po-
sition the right end of the log in between the two tabs
and the left end of the log into the grate post.
918-111c
01/03/08
LOG SET INSTALLATION
P121 / P131
Page 1 of 2
Tab on Burner
IMPORTANT
When placing Embers, do not block burner ports
as this can cause an incorrect fl ame pattern,
carbon deposits and delayed ignition.
2)
Place embers on the burner as shown below.
Separate platinum embers and place on the burner
over top of and around embers. Platinum embers can
cover burner ports. Avoid stacking platinum embers.
1)
Carefully remove the logs from the box and unwrap
them. The logs are fragile, handle with care -
do not
force into position.
326
326