background image

Regency Hume Freestanding Wood Fire

9

9)

  During the first few days it may be more 

difficult to start the fire. As you dry out your 

firebrick and your masonry flue, your draft 

will increase.

10)

 For those units installed at higher elevations 

or into sub-standard masonry fireplaces, 

drafting problems may occur. Consult an 

experienced dealer or mason on methods 

of increasing your draft.

11) 

Some cracking and popping noises may be 

experienced during the heating up process. 

These noises will be minimal when your unit 

reaches temperature.

12)

 Before opening your door to reload, open 

draft fully for approximately 10 to 15 seconds 

until fire has been re-established. This will 

minimize any smoking.

13)

 All fuel burning appliances consume oxygen 

during operation.  It is important that you 

supply a source of fresh air to your unit 

while burning. A slightly opened window is 

sufficient for the purpose.  If you also have 

a fireplace in your home, a downdraft may 

be created by your Regency Stove causing 

a draft down your chimney. If this occurs, 

slightly open a window near your unit.

CAUTION:  If the body of your unit, flue baffle 

or any part of the chimney connector starts 

to glow, you are overfiring.  Stop loading fuel 

immediately and close the draft control until 
the glow has completely subsided.

14) 

Green or wet wood is not recommended for 

your unit.  If you must add wet or green fuel, 

open the draft control fully until all moisture 

has  been  dispersed  by  the  intense  fire.  

Once all moisture has been removed, the 

draft control may be adjusted to maintain 

the fire.

15)

 If you have been burning your stove on a 

low draft, use caution when opening the 

door.  After opening the damper, open the 

door a crack, and allow the fire to adjust 

before fully opening the door.

16)

 The controls of your unit or the air supply 

passages should not be altered to increase 

firing for any reason.

17)

 If you burn the unit too slowly or at too low 

a setting your unit will not be operating as 

efficiently as it can.  An easy rule of thumb 

says that if your glass is clean, then your 

flue  is  clean  and  your  exhaust  is  clean.  

Burn the stove hot enough to keep your 

glass clean and you won't need to clean 

your flue as often.

   

MAINTENANCE

CREOSOTE

When wood is burned slowly, it produces 

tar and other organic vapours, which when 

combined with moisture, form creosote. The 

creosote vapours condense in the relatively 

cool chimney flue of a slow burning fire. As a 

result, creosote residue accumulates on the flue 

lining.  When ignited, this creosote can result 

in an extremely hot fire.

WARNING:  Things to remember in case 

of a chimney fire:

1. Close all draft and damper controls.

2. CALL THE FIRE DEPARTMENT.

Ways to Prevent and Keep Unit 

Free of Creosote

1) 

Burn stove with the draft control wide open 

for about 10-15 minutes every morning 

during burning season.

2) 

Burn stove with draft control wide open for 

about 10 - 15 minutes every time you apply 

fresh wood. This allows the wood to achieve 

the charcoal stage faster and burns up any 

unburned gas vapours which might other-

wise be deposited within the system.

3)  Only burn seasoned wood!

  Avoid burning 

wet or green wood. Seasoned wood has 

been dried at least one year.

4) 

A  small  hot  fire  is  preferable  to  a  large 

smouldering one that can deposit creosote 

within the system.

WOOD STORAGE

Store wood under cover, such as in a shed, or 

covered with a tarp, plastic, tar paper, sheets 

of scrap plywood, etc., as uncovered wood can 

absorb water from rain or snow, delaying the 

seasoning process.

MAINTENANCE

It is very important to carefully maintain your 

fireplace  stove,  including  burning  seasoned 

wood and maintaining a clean stove and chim-

ney system. Have the chimney cleaned before 

the burning season and as necessary during 

the season, as creosote deposits may build up 

rapidly. Moving parts of your stove require no 

lubrication.

 

5) 

The chimney and chimney connector should 

be inspected at least once every two months 

during the heating season to determine is a 

creosote buildup has occurred.

6)

 

Have chimney system and unit cleaned 

by competent chimney sweeps twice a 

year during the first year of use and at 

least once a year thereafter or when a 

significant layer of creosote has accu

-

mulated (3 mm/1/8" or more) it should be 

removed to reduce the risk of a chimney 

fire. 

GLASS MAINTENANCE

Your Regency stove is supplied with 5 mm 

Neoceram ceramic glass that will withstand 

the highest heat that your unit will produce.  In 

the event that you break your glass by impact, 

purchase your replacement from an authorized 

Regency dealer only, and follow our step-by-step 

instructions for replacement. 

Allow the stove to cool down before cleaning 

the glass, do not clean the glass when it is hot. 

Do not use abrasive cleaners.

 

Rear View of Door shown

Allen

Screw

Latching 

Sleeve

Set Screw

DOOR LATCH

ADJUSTMENT

The door latch may require adjustment as the 

door gasket material compresses over time.  

Follow  the  steps  below  to  allow  the  latch  to 

be moved closer to the door frame, causing a 

tighter seal;

1)

  Unscrew latching sleeve.

2)

  Remove allen screw.

3)

  Spin door handle clockwise to desired depth.

4)

  Re-install allen screw and latching sleeve.

5)

  Adjust set screw to proper depth to ensure  

       that the handle does not rotate 360 degrees.

Содержание F250B

Страница 1: ... For assistance or additional information consult an authorised installer service agency or the distributor FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorised installer service agency or the gas supplier HUME FREESTANDING WOOD FIRE FPI FIREPLACE PRODUCTS AUSTRAL...

Страница 2: ...d fire is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit ONLY CLEAN THE APPLIANCE WITH A...

Страница 3: ...ance 9 Door Latch Adjustment 9 Wood Storage 9 PARTS LIST Stove Assembly 10 WARRANTY Warranty 11 Data Badge 4 Unit Dimensions 5 INSTALLATION Residential Installation 6 Safety Guidelines and Warnings 6 Brick Cast Installation 6 Clearance to Combustibles 7 Floor Protection 7 OPERATING INSTRUCTIONS Operating Instructions 8 Air Slide Control 8 First Fire 8 ...

Страница 4: ...hat accompanies each F250B Freestanding Wood Fire We have printed a copy of the contents here for your review SAFETY LABEL NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one ...

Страница 5: ...Regency Hume Freestanding Wood Fire 5 UNIT DIMENSIONS ...

Страница 6: ...s preventsmoke spillage as this may set off a false alarm 5 Do not overfire heater If the chimney con nector flue baffle or the stove top begin to glow youareoverfiring Stopaddingfueland close the draft control Overfiring can cause extensive damage to your stove including warpage and premature steel corrosion Overfiring will void your warranty 6 Do not permit creosote or soot build up in the chimn...

Страница 7: ...ot less than 4 6m above the top of the floor protector NOTE Installation must be carried out by a licensed installer in accordance with AS NZS 2918 2001 Flo Met Super Single 1 Hawkwind Standard AHD Special Insulated 2 IMPORTANT 1 The Flomet Super Single flue kit must be installed with a 130o x 900mm stainless reflective shield between decromesh 2 The AHD Special Insulated flue kit must be installe...

Страница 8: ...fle OPERATING INSTRUCTIONS With your unit now correctly installed and safety inspected by your local authority you are now ready to start a fire Before establishing your first fire it is important that you fully understand the operation of your draft control CAUTION THIS APPLIANCE MUST BE MAINTAINEDANDOPERATEDATALLTIMES IN ACCORDANCE WITH THESE INSTRUC TIONS CAUTION THE USE OF SOME TYPES OF PRESER...

Страница 9: ... an extremely hot fire WARNING Thingstorememberincase of a chimney fire 1 Close all draft and damper controls 2 CALL THE FIRE DEPARTMENT Ways to Prevent and Keep Unit Free of Creosote 1 Burn stove with the draft control wide open for about 10 15 minutes every morning during burning season 2 Burn stove with draft control wide open for about 10 15 minutes every time you apply freshwood Thisallowsthe...

Страница 10: ...1 Top Plate Panel 6 1172004 Rear Panel 7 8010301 Bricks Set Set 9 8 8010302 Liner Cast Iron Set 9 8010303 Liner Cast Iron Sides L R 10 8010305 Liner Cast Iron Back 11 8010306 Air Bar Stainless Steel 12 8010307 Glass Neoceram With Gasket 13 8010313 Door Assembly without handle 14 8010309 Air Slide 15 8010310 Ash Lip Panel 16 8010114 Door Handle Set 17 F250 917 Fan Assembly 18 1172003 Pedestal Assem...

Страница 11: ...s the general practice of Regency Fireplace Products to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to Regency Fireplace Products and evaluated for manufacturer defect The authorised selling dealer is responsible for all in field service work carried out on your Regency product Regency Fireplace Products will not be liable for re...

Страница 12: ...alled _______________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com au Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions ev...

Отзывы: