background image

Regency Hume Freestanding Wood Fire

8

OPERATING INSTRUCTIONS

4)

  After about 45 minutes, when your wood 

has begun to burn strongly, adjust your draft 

control down to keep the fire at a moderate 

level.

 

WARNING:  Never build a roaring fire in 

a cold stove.  Always warm your stove 

up slowly!

5)

  Once a bed of coals has been established 

on the base of the firebox, you may adjust 

the draft control to a low setting to operate 

the unit at its most efficient mode.

6)

  During the first few fires, keep the combus

-

tion rate at a moderate level and avoid a 

large fire. Only after 5 or 6 such fires can 

you operate the stove at its maximum 

setting, and only after the metal has been 

warmed.

7)

  For the first few days, the stove will give 

off an odour from the paint. This is to be 

expected as the high temperature paint 

becomes seasoned. Windows and/or doors 

should be left open to provide adequate 

ventilation while this temporary condition 

exists.   Burning the stove at a very high 

temperature the first few times may damage 

the paint. Burn fires at a moderate level the 

first few days.

8)

  Do not place anything on the stove top 

during the curing process. This may result 

in damage to your paint finish.

Pull - Open

WARNING:  To build a fire in ignorance 

or to disregard the information con-

tained in this section can cause serious 

permanent damage to the unit and void 

your warranty!!

AIR SLIDE CONTROL

Both the primary and air wash drafts are control-

led by the control rod located on the right side 

of the unit (when facing the unit). To increase 

your draft - pull open, and to decrease - push 

closed.  All units have a secondary draft system 

that continually allows combustion air to the 

induction  ports  at  the  top  of  the  firebox,  just 

below the flue baffle.  

OPERATING 

INSTRUCTIONS

With your unit now correctly installed and safety 

inspected by your local authority, you are now 

ready to start a fire.  Before establishing your 

first fire, it is important that you fully understand 

the operation of your draft control.

CAUTION: THIS APPLIANCE MUST BE 

MAINTAINED AND OPERATED AT ALL TIMES 

IN ACCORDANCE WITH THESE INSTRUC-

TIONS.

CAUTION: THE USE OF SOME TYPES OF 

PRESERVATIVE-TREATED WOOD AS A FUEL 

CAN BE HAZARDOUS.

WARNING: ANY MODIFICATION OF THE AP-

PLIANCE THAT HAS NOT BEEN APPROVED 

IN WRITING BY THE TESTING AUTHORITY 

IS CONSIDERED AS BREACHING AS/NZS 

4013.

WARNING: DO NOT USE FLAMMABLE 

LIQUIDS OR AEROSOLS TO START OR 

REKINDLE THE FIRE.

WARNING: DO NOT USE FLAMMABLE LIQ-

UIDS OR AEROSOLS IN THE VICINITY OF 

THIS APPLIANCE WHEN IT IS OPERATING.

WARNING: DO NOT STORE FUEL WITHIN 

HEATER INSTALLATION CLEARANCES.

WARNING: OPEN AIR CONTROL (AND 

DAMPER WHEN FITTED) BEFORE OPENING 

FIRING DOOR.

For safety reasons and in order to avoid 

over firing of your unit do not burn your 

fire with the door open or ajar.

FIRST FIRE

When your installation is completed and in-

spected you are ready for your first fire.

1)

  Open control fully.

2)

  Open firebox door and build a small fire us

-

ing paper and dry kindling on the firebrick 

hearth.  Secure door on the firebox and wait 

a few minutes for a good updraft in the flue to 

establish the fire.  (Leaving the door slightly 

open will help your fire start more rapidly.)

 

CAUTION:  Never leave unit unattended 

if door is left open.  This procedure is for 

fire start-up only, as unit may overheat 

if door is left open for too long.

3)

  With the draft still in the fully open position 

add two or three seasoned logs to your  fire. 

Form a trench in the ash bed to allow air to 

reach the rear of the firebox prior to closing 

the door.

Push - Closed

3 Speed Internal Fan Wiring Diagram (240V)

HOT -"BROWN"

NEUTRAL -"BLUE"

GREEN-YELLOW

RED

BLACK

ATTACH TO FAN

WHITE

BLUE

Содержание F250B

Страница 1: ... For assistance or additional information consult an authorised installer service agency or the distributor FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorised installer service agency or the gas supplier HUME FREESTANDING WOOD FIRE FPI FIREPLACE PRODUCTS AUSTRAL...

Страница 2: ...d fire is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit ONLY CLEAN THE APPLIANCE WITH A...

Страница 3: ...ance 9 Door Latch Adjustment 9 Wood Storage 9 PARTS LIST Stove Assembly 10 WARRANTY Warranty 11 Data Badge 4 Unit Dimensions 5 INSTALLATION Residential Installation 6 Safety Guidelines and Warnings 6 Brick Cast Installation 6 Clearance to Combustibles 7 Floor Protection 7 OPERATING INSTRUCTIONS Operating Instructions 8 Air Slide Control 8 First Fire 8 ...

Страница 4: ...hat accompanies each F250B Freestanding Wood Fire We have printed a copy of the contents here for your review SAFETY LABEL NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one ...

Страница 5: ...Regency Hume Freestanding Wood Fire 5 UNIT DIMENSIONS ...

Страница 6: ...s preventsmoke spillage as this may set off a false alarm 5 Do not overfire heater If the chimney con nector flue baffle or the stove top begin to glow youareoverfiring Stopaddingfueland close the draft control Overfiring can cause extensive damage to your stove including warpage and premature steel corrosion Overfiring will void your warranty 6 Do not permit creosote or soot build up in the chimn...

Страница 7: ...ot less than 4 6m above the top of the floor protector NOTE Installation must be carried out by a licensed installer in accordance with AS NZS 2918 2001 Flo Met Super Single 1 Hawkwind Standard AHD Special Insulated 2 IMPORTANT 1 The Flomet Super Single flue kit must be installed with a 130o x 900mm stainless reflective shield between decromesh 2 The AHD Special Insulated flue kit must be installe...

Страница 8: ...fle OPERATING INSTRUCTIONS With your unit now correctly installed and safety inspected by your local authority you are now ready to start a fire Before establishing your first fire it is important that you fully understand the operation of your draft control CAUTION THIS APPLIANCE MUST BE MAINTAINEDANDOPERATEDATALLTIMES IN ACCORDANCE WITH THESE INSTRUC TIONS CAUTION THE USE OF SOME TYPES OF PRESER...

Страница 9: ... an extremely hot fire WARNING Thingstorememberincase of a chimney fire 1 Close all draft and damper controls 2 CALL THE FIRE DEPARTMENT Ways to Prevent and Keep Unit Free of Creosote 1 Burn stove with the draft control wide open for about 10 15 minutes every morning during burning season 2 Burn stove with draft control wide open for about 10 15 minutes every time you apply freshwood Thisallowsthe...

Страница 10: ...1 Top Plate Panel 6 1172004 Rear Panel 7 8010301 Bricks Set Set 9 8 8010302 Liner Cast Iron Set 9 8010303 Liner Cast Iron Sides L R 10 8010305 Liner Cast Iron Back 11 8010306 Air Bar Stainless Steel 12 8010307 Glass Neoceram With Gasket 13 8010313 Door Assembly without handle 14 8010309 Air Slide 15 8010310 Ash Lip Panel 16 8010114 Door Handle Set 17 F250 917 Fan Assembly 18 1172003 Pedestal Assem...

Страница 11: ...s the general practice of Regency Fireplace Products to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to Regency Fireplace Products and evaluated for manufacturer defect The authorised selling dealer is responsible for all in field service work carried out on your Regency product Regency Fireplace Products will not be liable for re...

Страница 12: ...alled _______________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com au Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions ev...

Отзывы: