32
F2500 Regency Freestanding Woodstove
maintenance
NOTE:
Replacement combustors can be retrieved from Applied Ceramics
or contact your local Regency Dealer—see warranty information at
the back of this manual for details.
DO NOT OPERATE THE APPLIANCE IF COMBUSTOR BECOMES
INACTIVE - DO NOT OPERATE WITHOUT COMBUSTOR.
Secondary Air Tube Removal / Installation
1. Allow the stove to burn out and cool down, until cool to touch.
2. Open stove door to access secondary air tubes.
3. Grasp secondary air tube firmly with vise grips, using a hammer tap vise
grips from right to left until air tube is released from grip. Remove.
4. Remove top left and right metal retainers, followed by the fragile three piece
C-Cast Baffles (see catalyst removal instructions for details), then remove
the remaining 2 tubes.
Secondary Air
Tubes
5. To reinstall or replace, first slide left side of tube into hole on left side air
channel. Align tab on right side air channel with notch on right hand end of
air tube. Firmly grip center of air tube with vise grips, use hammer to tap vise
grips from left to right until the tube bottoms out into the air channel on right.
Annual Maintenance
Completely clean out entire unit
Annually
Inspect air tube, Catalytic Combustor and bricks
Replace any damaged parts.
Adjust door catch assembly
If unable to obtain a tight seal on the door - replace door gasket seal.
Readjust door catch after new gasket installed.
Inspect condition and seal of:
Glass Gasket
Door Gasket
Perform paper test - replace gasket if required
Paper Test
Test the seal on the loading door with a paper bill.
Place a paper bill in the gasket area of the door on a cold stove.
Close the door.
Try to remove the paper by pulling.
The paper should not pull out easily, if it does, try adjusting the door latch, if that doesn't
solve the problem replace the door gasket.
Check and lubricate door hinge + latch
Use only high temperature anti seize lube. (ie. never seize)
Check glass for cracks
Replace if required.
Clean blower motor
Disconnect power supply.
Remove and clean blower.
*DO NOT LUBRICATE*
Inspect and clean chimney
Annual professional chimney cleaning recommended.
Thermostat Probe
The thermostat probe that is inserted into the opening, must be cleaned at least
once a year. Use 220 sand paper to clean probe.
NOTE:
Chimney Cleaning
When cleaning the chimney system the catalyst should be removed so this can also be cleaned at the same time following the guide lines
found in this manual. The bypass should be open so any creosote will fall onto the firebox floor when being cleaned and door closed. The
monitor should also be removed when cleaning is being done to prevent damage to the monitor.
We highly recommend that the chimney cleaning be done by a professional as they will have the necessary tools such as a proper sized
brush and special vacuum cleaner designed to deal with fine particles.
Содержание Cascades Series
Страница 34: ...34 F2500 Regency Freestanding Woodstove parts list 7 9 8 22 3 6 5 4 23 2 18 13 1 14 10 17 12 11 16 19 20 21 ...
Страница 42: ......
Страница 44: ...44 F2500 Regency Freestanding Woodstove notes ...
Страница 45: ...F2500 Regency Freestanding Woodstove 45 notes ...
Страница 46: ...46 F2500 Regency Freestanding Woodstove notes ...
Страница 47: ...F2500 Regency Freestanding Woodstove 47 ...