background image

Regency Bellerive Fireplace Insert

6

INSTALLATION

1)

  Please read this entire manual before you 

install and use your new wood fi re. Failure 
to follow instructions may result in property 
damage, bodily injury or even death. Be 
aware that local Codes and Regulations may 
override some items in this manual. Check 
with your local inspector.

2)

 

THE APPLIANCE AND FLUE-SYSTEM 
SHALL BE INSTALLED IN ACCORD-
ANCE WITH AS/NZS 2918:2001 AND 
THE APPROPRIATE REQUIREMENTS 
OF THE RELEVANT BUILDING CODE OR 
CODES.

 

APPLIANCES INSTALLED IN ACCORD-
ANCE WITH THIS STANDARD SHALL 
COMPLY WITH THE REQUIREMENTS OF 
AS/NZS 4013 WHERE REQUIRED BY THE 
REGULATORY AUTHORITY. 

 

ANY MODIFICATION OF THE APPLIANCE 
THAT HAS NOT BEEN APPROVED IN 
WRITING BY THE TESTING AUTHORITY 
IS CONSIDERED TO BE IN BREACH OF 
THE APPROVAL GRANTED FOR COMPLI-
ANCE WITH AS/NZS 4013.

RESIDENTIAL 

INSTALLATION

Regency Inserts are constructed with the high-
est quality materials and assembled under strict 
quality control procedures that insure years of 
trouble free and reliable performance.

It is important that you read this manual thor-
oughly and fully understand the safe instal-
lation and operating procedures.  The more 
you understand the way your Regency Insert 
operates, the more enjoyment you will experi-
ence from knowing that your unit is operating 
at peak performance.

BEFORE INSTALLING

YOUR INSERT

1)

  Please read this entire manual before you 

install and use your new wood insert. Failure 
to follow instructions may result in property 
damage, bodily injury or even death. Install 
and use only in accordance with manufactur-
er’s installation and operating instructions.

2)

  Check your local building codes - Building 

Inspection Department.  You may require 
a permit before installing your insert. Be 
aware that local codes and regulations may 
override some items in the manual.

 

WARNING:  Careless installation is the 
major cause of safety hazard.  Check all 
local building and safety codes before 
installation of unit.

3)

  Notify your home insurance company that 

you plan to install a fi replace insert or hearth 
heater.

4) 

Your fi replace insert is heavy and requires 
two or more people to move it safely.  The 
insert can be badly damaged by mishan-
dling.

5)

  If your existing fi replace damper control 

will become inaccessible once you have 
installed your Regency Insert, you should 
either remove or secure it in the open posi-
tion.

6)

 Inspect your fi replace and chimney prior 

to installing your insert to determine that it 
is free from cracks, loose mortar or other 
signs of damage.  If repairs are required, 
they should be completed before installing 
your insert.  Do not remove bricks or mortar 
from your masonry fi replace.

7)

 

Do not connect the insert to a chimney 
system servicing another appliance or 
an air distribution duct.

 

CAUTION: MIXING OF APPLIANCE OR 
FLUE-SYSTEM COMPONENTS FROM 
DIFFERENT SOURCES OR MODIFYING 
THE DIMENSIONAL SPECIFICATION OF 
COMPONENTS MAY RESULT IN HAZ-
ARDOUS CONDITIONS. WHERE SUCH 
ACTION IS CONSIDERED, THE MANU-
FACTURER SHOULD BE CONSULTED 
IN THE FIRST INSTANCE.

3) 

Re-confi rm the clearance from the insert to 
combustibles to insure that they are within 
the prescribed limits.

4) 

Install chimney according to chimney manu-
facturers instructions. The performance of 
your wood fi re is governed to a very large 
part by the chimney system. Too short a 
chimney can cause diffi cult start-up, dirty 
glass, backsmoking when door is open, and 
even reduced heat output. Too tall a chimney 
may prompt excessive draft which can result 
in very short burn times and excessive heat 
output. 

5)

 The 

fl oor protector must be of non-combus-

tible material.  

6)

 

Do not connect this unit to a chimney 
serving another appliance.

Содержание Bellerive I200B

Страница 1: ...l August 20 2012 918 696a WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult an authorised installer service agency or the distributor BELLERIVE FIREPLACE INSERT ...

Страница 2: ...anual please contact the REGENCY DEALER in your area Keep those REGENCY FIRES burning SAFETY NOTE If this wood fire is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction sho...

Страница 3: ... Storage 12 PARTS LIST Stove Assembly 13 WARRANTY Warranty 15 Data Badge 4 Unit Dimensions 5 INSTALLATION Before Installing Your Insert 6 Residential Installation 6 Safety Guidelines and Warnings 7 Chimney Specifications 7 Wood Insert Specifications 7 Brick Cast Installation 7 Zero Clearance Dimensions 7 Zero Clearance Box Dimensions 7 Fireplace Clearances 8 Installation into a Masonry Fireplace 9...

Страница 4: ... that accompanies each I200B Fireplace Insert We have printed a copy of the contents here for your review SAFETY LABEL NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one ...

Страница 5: ...Regency Bellerive Fireplace Insert 5 UNIT DIMENSIONS ...

Страница 6: ...ur insert Be aware that local codes and regulations may override some items in the manual WARNING Careless installation is the major cause of safety hazard Check all local building and safety codes before installation of unit 3 Notify your home insurance company that you plan to install a fireplace insert or hearth heater 4 Your fireplace insert is heavy and requires two or more people to move it ...

Страница 7: ...ety reasons a guard around the fire is recommended 8 The stove consumes air while operating provide adequate ventilation with an air duct or open a window while the stove is in use 9 Do not use grates or andirons or other methods for supporting fuel Burn directly on the base or bricks where supplied 10 Open the draft control fully for 10 to 15 seconds prior to slowly opening the door when refuelli...

Страница 8: ...Regency Bellerive Fireplace Insert 8 INSTALLATION ZERO CLEARANCE BOX DIMENSIONS ZERO CLEARANCE DIMENSIONS ...

Страница 9: ...Regency Bellerive Fireplace Insert 9 FIREPLACE CLEARANCES INSTALLATION ...

Страница 10: ... When a flue or liner is in use the insert is able to breathe better by allowing a greater draft to be created The greater draft can decrease problemssuchas difficultstart ups smoking out the door and dirty glass 2 In order to position the flue liner the exist ing rain cap must be removed from your chimney system In most cases the flue damper should also be removed to allow passage of the liner 3 ...

Страница 11: ...eft side of the fascia in behind the door hinges and align the 4 screw holes with the holes in the firebox Secure in place using 2 screws on top 4 Install the fan fascia by aligning the bottom screw locations with the bottom faceplate See page 13 for fan wiring diagram 5 Re install door Fan Fascia 6 Install the draft plate cover by sliding the tabs into the tab brackets on the inside top of the fi...

Страница 12: ...s at the top of the firebox just below the flue baffle OPERATING INSTRUCTIONS With your unit now correctly installed and safety inspected by your local authority you are now ready to start a fire Before establishing your first fire it is important that you fully understand the operation of your draft control CAUTION THIS APPLIANCE MUST BE MAINTAINEDANDOPERATEDATALLTIMES IN ACCORDANCE WITH THESE IN...

Страница 13: ...n extremely hot fire WARNING Thingstorememberincase of a chimney fire 1 Close all draft and damper controls 2 CALL THE FIRE DEPARTMENT Ways to Prevent and Keep Unit Free of Creosote 1 Burn stove with the draft control wide open for about 10 15 minutes every morning during burning season 2 Burn stove with draft control wide open for about 10 15 minutes every time you apply freshwood Thisallowsthewo...

Страница 14: ...n Liner set 6 8010303 Cast Iron Liner Sides L or R 7 8010305 Cast Iron Liner Back 8 8010306 Stainless Steel Air Bar STOVE ASSEMBLY Part Description PARTS LIST Internal Blower Wiring Diagram 240V Hot Brown Neutral Blue Green Yellow Black Red Attach to Fan Ⅰ Ⅱ 9 8010402 Glass Neoceram w Gasket 10 8010403 Air slide 11 8010406 Door Assembly without handle 12 8010114 Door Handle Set 8010408 Hinge Bar 8...

Страница 15: ...unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that all submitted claims provide all of the necessary information in cluding customer name purchase date serial type of unit problem and part or parts requested without this in...

Страница 16: ...ights reserved FIREPLACE PRODUCTS AUSTRALIA PTY LTD 21 23 SOUTH LINK DANDENONG SOUTH VICTORIA 3175 AUSTRALIA NOTE PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION IS NOT COVERED BY WARRANTY A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES ...