Regency Bellerive & Berwick Zero Clearance Box and Flue Kit  

Part No 946-762 Assembly Instructions 

 

 

 

Kit Contents 

 

63 screws 

 

 

Base assembly 

 

 

LH Inner side panel 

 

RH Inner side panel 

 

Back Inner panel 

 

Top Inner panel 

 

 

LH Outer side panel 

 

RH Outer side panel 

 

Back Outer panel 

 

Top Outer panel 

 

 

Inner Flue locating plate 

 

Outer Flue locating plate 

Содержание Bellerive I200B-1

Страница 1: ...m au 1 Regency Bellerive Berwick Zero Clearance Box and Flue Kit Part No 946 762 Assembly Instructions Kit Contents 63 screws Base assembly LH Inner side panel RH Inner side panel Back Inner panel Top Inner panel LH Outer side panel RH Outer side panel Back Outer panel Top Outer panel Inner Flue locating plate Outer Flue locating plate ...

Страница 2: ... be installed at floor level Inner panel assembly 1 Locate the 4 x inner panels holes for inner panel are larger than the outer panels 2 Fit inner right hand side panel to rear inner panel ventilation holes to the bottom Screw to rear panel from the outside 3 Repeat step 2 with the left hand side panel 4 Fit inner top panel panel fits outside rear side panels with stiffener plate at the top front ...

Страница 3: ...ft hand side panel ventilation holes to the bottom panel fits between inner return front and base panel Screw to base from outside 7 Fit outer rear panel sticker facing out ventilation holes to the bottom panel will slide inside returns rear on outer side panels Screw to base and sides from outside 8 Fit outer top panel panel fits on outside of outer side and rear panels Screw from outside 9 Fit b...

Страница 4: ...talled Bellerive flue outlet should be located at the rear most position and the Berwick at the foremost Bellerive ensure the locating plate is installed in the direction of the image below Berwick ensure the locating plate is installed in the direction of the image below 11 Repeat step above for outer locating plate installing over the top of the inner locating plate Important Orientation of flue...

Страница 5: ...ted Bellerive flue outlet should be located at the rear most position and the Berwick at the foremost Flue Assembly Ensure first length of 8 and 10 flue fitted into flue locating plates is ventilated at the bottom both pieces and fitted with the crimp up Assemble the rest of the flue and install the ZC box according to the heater specific clearances as stated in the installation manual Make sure t...

Страница 6: ...the box is raised up from floor level when wall cladding e g Villa Board is fitted around the box a gap of 25mm will be exposed at the base of the unit under the fan housing This gap would normally be covered by the hearth when the unit is installed at floor level Allowances will have to be made to cover this gap when cladding the wall if the unit is raised above floor level Summary of Hearth Clea...

Страница 7: ...ce installed with a triple skin flue kit conforms to the requirements of the joint AS NZS 2918 2001 Standard Appendix B Test Position The appliance must be built into an enclosure with the walls surrounding the fuel loading door front wall made from 13mm FYRCHEK plaster board or a minimum 9mm non combustible material Bellis board or similar A 20mm gap must be maintained between the outer case of t...

Страница 8: ...l appliance installed with a triple skin flue kit conforms to the requirements of the joint AS NZS 2918 2001 Standard Appendix B Test Position The appliance must be built into an enclosure with the walls surrounding the fuel loading door front wall made from 13mm FYRCHEK plaster board or a minimum 9mm non combustible material Bellis board or similar A 20mm gap must be maintained between the outer ...