Flue locating plate pictured above is in the correct position for the Bellerive.
Prior to installing box ensure flue locating plate is correctly fitted – “Bellerive” flue outlet should be
located at the rear most position and the “Berwick” at the foremost.
Flue Assembly
Ensure first length of 8” and 10” flue fitted into flue locating plates is ventilated at the bottom
(both pieces) and fitted with the “crimp up”
Assemble the rest of the flue and install the ZC box according to the heater specific clearances as
stated in the installation manual. Make sure the 10inch ventilated galvanized piece shown above
is the top length that fits into the cowl.