background image

6-7/8"

(173mm)

dia. Flue pipe

4" (102mm)

dia. flue pipe

Wall Thimble (2 pc)

Termination Cap

(Part# 946-523/P)

AstroCap

TM

spring
spacer

FPI Direct  Vent System (Flex)

Horizontal Terminations Only

This venting system, in combination with the P33 Direct Vent Gas 
Fireplace, have been tested and listed as a direct vent heater system by 
Warnock Hersey. The location of the termination cap must conform to the 
requirements in the Vent Terminal Locations diagram, see manual.

FPI Direct Vent (Flex) System Termination Kits include all the parts 
needed to install the P33 using a 

fl

 exible vent.

FPI Kit # 

Length  Contains:

#946-513

2 Feet

1)

 6-5/8” 

fl

 exible liner (Kit length)

2)

 4” 

fl

 exible liner (Kit length)

3)

  spring spacers (3)

4)

 thimble 

(2)

5)

 

AstroCap

 termination cap (1)

6)

 screws 

(12)

7)

  tube of Mill Pac (1)

8)

  plated screws (8)

9)

  S.S. screws #8 x 1-1/2” drill point, (4)

#946-515

4 Feet

#946-516

10 Feet

Notes: 
1)  Liner sections should be continuous without any joints or seams.
2)  Only Flex pipe purchased from Regency may be used for Flex 

installations.

3)  Horizontal sections must be supported every 3 feet.

If required by the external termination location the listed 
alternate termination caps may be used. 

Important

When installing Cabinet Mantels: the wall thimble must be secured 

fi

 rst and venting must be attached to unit before sliding into 

fi

 nal 

position.

Alternate Horizontal 

Termination Caps

Snorkel Terminations

Snorkel Terminations:

For installations requiring a vertical rise on the exterior of the building, 
14-inch and 36-inch tall Snorkel Terminations and the Riser Vents are 
available. Follow the same installation procedures as used for standard 
Horizontal Termination. NEVER install the snorkel upside down.

Min. 12"*
(305mm)

Dura-Vent

Snorkel

Riser Vent

Termination

Min. 6-1/4"*

(159mm)

Below Grade Snorkel Installation (Dura-Vent Only)

If the Snorkel Termination must be installed below grade, i.e. basement 
application, proper drainage must be provided to prevent water from 
entering the Snorkel Termination. Refer to Rigid Pipe Installation 
instructions for details. Do not attempt to enclose the Snorkel within the 
wall, or any other type of enclosure.

Min.

12"*

(305mm)

Adequate

drainage

Window

Well

Gravel

Dura-Vent

Snorkel

P33 Gas Fireplace

32

August 2008 Product Speci

fi

 cations Book

Gas Fir

eplaces

Gas Fireplaces

Содержание 510-994

Страница 1: ...th Vertical 19 1 2 495mm Vertical Rise 16 1 2 419mm Rigid 12 3 4 324mm Flex Horizontal J Corner Wall Length 37 1 2 953mm K Corner Facing Wall Width 53 1 4 1353mm L Framed Chase Ceiling 36 914mm Rigid 32 813mm Flex M Vent Centerline Height 30 762mm Rigid 26 660mm Flex G H I K J L Q O P N M 10 254mm dia Hole through wall Vent Opening for gas connection Top Header Drywall or other facing R Dimension ...

Страница 2: ...m Floor 1 25mm minimum J Framing Depth Vertical 19 1 2 495mm Vertical Rise 16 1 2 419mm Rigid 12 3 4 324mm Flex Horizontal K Corner Wall Length 37 1 2 953mm L Corner Facing Wall Width 53 1 4 1353mm M Framed Chase Ceiling 36 914mm Rigid 32 813mm Flex N Vent Centerline Height 30 762mm Rigid 26 660mm Flex The unit must be raised a minimum of 1 above the finished floor Dimension H H I minimum Dimensio...

Страница 3: ...rs are shown in the diagram below Mantel may be installed anywhere in the shaded area or higher Drywall Mantel Clearances 2 0 12 6 4 8 10 0 Side View Top of Unit 12 305mm 3 1 2 89mm 7 1 2 191mm A 3 76mm Standoff B C D Note If desired a non combustible mantel may be installed at a lower height Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolo...

Страница 4: ...replace and vent system be installed only in accordance with these instructions Clearance Dimension Measured From A Front Floor Clearance min 1 25mm Underside of Unit B Sidewall 7 1 2 241mm Side of Unit C Ceiling room and or alcove 30 889mm Top of Unit D Alcove Width 48 1219mm Sidewall to Sidewall Minimum E Alcove Depth 36 914mm Front to Back Wall Maximum Flue Clearances to Combustibles Horizontal...

Страница 5: ...e supported every 3 feet If required by the external termination location the listed alternate termination caps may be used Important When installing Cabinet Mantels the wall thimble must be secured first and venting must be attached to unit before sliding into final position Alternate Horizontal Termination Caps Snorkel Terminations Snorkel Terminations For installations requiring a vertical rise...

Страница 6: ... must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustible materials Minimum of 1 pipe section between elbows Note Must use optional rigid pipe adapter when using Rigid Pipe Part 510 994 Unit must be raised by 1 when using Contemporary Faceplate Maximum 40 ft 12 2m Minimum 9 6 2 9m Minimum 8 6 2 6m Max 10 3m cen...

Страница 7: ...x 6 Min Vertical Venting with Three 3 90 Elbows Initial vertical section Two 45 elbows One 90 elbow Option V H H1 V V1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 8 feet Minimum of 1 foot between 90 elbows is required A 2 Min 3 Max 4 Min B 3 Min 4 Max 6 Min C 4 Min 5 Max 7 Min D 5 Min 6 Max 8 Min E 6 Min 7 Max 9 Min F 7 Min 8 Max 10 M...

Страница 8: ...ibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A vent guard may be required as per local codes refer to Exterior Vent Termination Locations Note FPIDirectVentSystem Flex isonlyapprovedforhorizontal terminations P33 Gas Fireplace Unit must be raised by 1 when using Contemporary Faceplate Please refer to Exterior Ve...

Страница 9: ... Horizontal Venting with Three 3 90 Elbows Initial vertical section Two 45 elbows One 90 elbow Option V H V V1 H H1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 8 feet Minimum of 1 foot between 90 elbows is required A 2 Min 1 Max 3 Min 4 Max B 3 Min 2 Max 4 Min 5 Max C 4 Min 3 Max 6 Min 6 Max D 5 Min 4 Max 8 Min 7 Max E 6 Min 5 Max 10 ...

Страница 10: ... inlet air collar of the termination cap This appliance is designed to be attached to two 3 76mm co linear aluminium flex running the full length of the chimney See the Venting Arrangements for minimum and maximum heights Required Parts Part Description 946 529 Co linear DV Vertical Termination Cap 948 305 3 Flex 35 ft 946 563 Coaxial to Co linear Adapter Kit 510 994 Rigid Pipe Adapter 58dva E45 4...

Отзывы: