P33 Gas Fireplace
Combustible Mantels with
Contemporary Faceplate
Because of the extreme heat this
fi
replace emits, the mantel
clearances are critical.
Combustible mantel clearances from top of
the louvers are shown in the diagram below. Mantel may be installed
anywhere in the shaded area or higher.
Mantel Leg Clearances with
Contemporary Faceplate
Combustible mantel leg clearances from side of unit as per diagram
below:
Clearances are from the
fi
nished edge of the unit or an installed front.
Caution Requirements
The top, back and sides of the
fi
replace are de
fi
ned by
standoffs. The metal ends of the standoff may
NOT
be
recessed into combustible construction.
WARNING
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this
fi
replace and vent
system be installed only in accordance with these instructions.
Clearance:
Dimension
Measured
From:
A: *Front Floor Clearance
(min.)
1" (25mm)
Underside of
Unit
B: *Sidewall
7-1/2" (241mm)
Side of Unit
C: *Ceiling
(room and/or alcove)
30" (889mm)
Top of Unit
D: Alcove Width
48" (1219mm)
Sidewall to
Sidewall
(Minimum)
E: Alcove Depth
36" (914mm)
Front to
Back Wall
(Maximum)
Flue Clearances to
Combustibles
Horizontal - Top
2-1/2"
Horiztonal - Side
1-1/2"
Horiztonal - Bottom
1-1/2"
Vertical (Flex Vent)
1-1/2"
Vertical (Rigid)
1-1/4"
*Note: All measurements are from the top/side
of the unit, not optional front.
Clearance Requirements with
Contemporary Faceplate
Top View
0-3
WARNING
Failure to maintain required clearances is a major cause of chimney related
fi
res.
Installation of this
fi
replace must comply with these clearances
Please note:
Due to ongoing product development, product appearance and speci
fi
cations
are subject to change without notice.
C
B
C
Close to Ceiling
31
August 2008 Product Speci
fi
cations Book
Gas Fireplaces