Framing and Finishing

1)

  Determine the total thickness of facing material (e.g. drywall plus 

ceramic tiles) to allow the 

fi

 nished surface to be 

fl

 ush with the front 

of the unit. Total facing thickness can vary from 1/2” (13mm) to 1-¼” 
(32mm) thick. 

2)

  Frame in the enclosure for the unit with framing material. 

3)

  For exterior walls, insulate the enclosure to the same degree as 

the rest of the house, apply vapor barrier and drywall, as per local 
installation codes. 

(Do not insulate the 

fi

 replace itself.)

4)

  The top of the unit must not be closer than 30” (762mm) to the 

ceiling.

5)

  Combustible material may be brought up to the top and 

sides of the unit and be covered with ceramic tiles, bricks, 
rock or other suitable combustible finishing materials.

Note: The unit does not have to be completely enclosed in a 
chase. The clearance on top of the unit is 0” to the standoffs 
so combustible building materials can be laid directly on top 
of the standoffs. You must maintain proper clearances from 
the vent to combustible materials (See Below).

6)

  Use metal studs for framing where the minimum clearance from 

the vent to combustible material cannot be maintained.

P33 Gas Fireplace

Combustible Mantels

Because of the extreme heat this 

fi

 replace emits, the mantel 

clearances are critical.

 Combustible mantel clearances from top of 

the louvers are shown in the diagram below. Mantel may be installed 
anywhere in the shaded area or higher.

Drywall

Mantel Clearances

2

0

12

6

4

8

10

0

Side View

Top of

Unit

12"(305mm)

3-1/2"(89mm)

7-1/2"(191mm)

A

3”

(76mm)

Standof

f

B

C

D

Note:  If desired a non-combustible mantel may be installed at a 

lower height.

Note:  Ensure the paint that is used on the mantel and the facing 

is “heat resistant” or the paint may discolour.

Mantel Leg Clearances

Combustible mantel leg clearances as per diagram below:
Clearances are from the 

fi

 nished edge of the unit or an installed front.

Maximum 
1-1/2” projection at 2” 
minimum clearance.

Mantel Clearances

A

B

C

D

Front

29” (737mm)

11” (279mm)

9” (229mm)

7” (178mm)

WARNING

Failure to maintain required clearances is a major cause of 
chimney related 

fi

 res.  Installation of this 

fi

 replace must comply 

with these clearances.

Clearance:

Dimension

Measured From:

A: Mantel Height

7” (178mm)

Minimum (Additional on this page)

B: Sidewall

7-1/2” (191mm)

Side of installed front

C: Ceiling

30” (762mm)

Top of installed unit

D: Mantel Depth

12” (305mm)

Maximum (Additional on this page)

E: Alcove Width

48” (1219mm)

Sidewall to Sidewall (Minimum)

F: Alcove Depth

36” (914mm)

Front to back wall (Maximum)

Top of Hearth must not be higher than the base of the 

fi

 rebox. 

Vent Clearances

Clearance Dimension

Horizontal - Top

2-1/2” (64mm)

Horizontal - Side

1-1/2” (38mm)

Horizontal - Bottom

1-1/2” (38mm)

Vertical - Flex

1-1/2” (38mm)

Vertical - Rigid

1-1/4” (32mm)

E

B

B

A

C

D

F

Clearance Requirements

30

August 2008 Product Speci

fi

 cations Book

Gas Fir

eplaces

Gas Fireplaces

Содержание 510-994

Страница 1: ...th Vertical 19 1 2 495mm Vertical Rise 16 1 2 419mm Rigid 12 3 4 324mm Flex Horizontal J Corner Wall Length 37 1 2 953mm K Corner Facing Wall Width 53 1 4 1353mm L Framed Chase Ceiling 36 914mm Rigid 32 813mm Flex M Vent Centerline Height 30 762mm Rigid 26 660mm Flex G H I K J L Q O P N M 10 254mm dia Hole through wall Vent Opening for gas connection Top Header Drywall or other facing R Dimension ...

Страница 2: ...m Floor 1 25mm minimum J Framing Depth Vertical 19 1 2 495mm Vertical Rise 16 1 2 419mm Rigid 12 3 4 324mm Flex Horizontal K Corner Wall Length 37 1 2 953mm L Corner Facing Wall Width 53 1 4 1353mm M Framed Chase Ceiling 36 914mm Rigid 32 813mm Flex N Vent Centerline Height 30 762mm Rigid 26 660mm Flex The unit must be raised a minimum of 1 above the finished floor Dimension H H I minimum Dimensio...

Страница 3: ...rs are shown in the diagram below Mantel may be installed anywhere in the shaded area or higher Drywall Mantel Clearances 2 0 12 6 4 8 10 0 Side View Top of Unit 12 305mm 3 1 2 89mm 7 1 2 191mm A 3 76mm Standoff B C D Note If desired a non combustible mantel may be installed at a lower height Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolo...

Страница 4: ...replace and vent system be installed only in accordance with these instructions Clearance Dimension Measured From A Front Floor Clearance min 1 25mm Underside of Unit B Sidewall 7 1 2 241mm Side of Unit C Ceiling room and or alcove 30 889mm Top of Unit D Alcove Width 48 1219mm Sidewall to Sidewall Minimum E Alcove Depth 36 914mm Front to Back Wall Maximum Flue Clearances to Combustibles Horizontal...

Страница 5: ...e supported every 3 feet If required by the external termination location the listed alternate termination caps may be used Important When installing Cabinet Mantels the wall thimble must be secured first and venting must be attached to unit before sliding into final position Alternate Horizontal Termination Caps Snorkel Terminations Snorkel Terminations For installations requiring a vertical rise...

Страница 6: ... must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustible materials Minimum of 1 pipe section between elbows Note Must use optional rigid pipe adapter when using Rigid Pipe Part 510 994 Unit must be raised by 1 when using Contemporary Faceplate Maximum 40 ft 12 2m Minimum 9 6 2 9m Minimum 8 6 2 6m Max 10 3m cen...

Страница 7: ...x 6 Min Vertical Venting with Three 3 90 Elbows Initial vertical section Two 45 elbows One 90 elbow Option V H H1 V V1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 8 feet Minimum of 1 foot between 90 elbows is required A 2 Min 3 Max 4 Min B 3 Min 4 Max 6 Min C 4 Min 5 Max 7 Min D 5 Min 6 Max 8 Min E 6 Min 7 Max 9 Min F 7 Min 8 Max 10 M...

Страница 8: ...ibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A vent guard may be required as per local codes refer to Exterior Vent Termination Locations Note FPIDirectVentSystem Flex isonlyapprovedforhorizontal terminations P33 Gas Fireplace Unit must be raised by 1 when using Contemporary Faceplate Please refer to Exterior Ve...

Страница 9: ... Horizontal Venting with Three 3 90 Elbows Initial vertical section Two 45 elbows One 90 elbow Option V H V V1 H H1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 8 feet Minimum of 1 foot between 90 elbows is required A 2 Min 1 Max 3 Min 4 Max B 3 Min 2 Max 4 Min 5 Max C 4 Min 3 Max 6 Min 6 Max D 5 Min 4 Max 8 Min 7 Max E 6 Min 5 Max 10 ...

Страница 10: ... inlet air collar of the termination cap This appliance is designed to be attached to two 3 76mm co linear aluminium flex running the full length of the chimney See the Venting Arrangements for minimum and maximum heights Required Parts Part Description 946 529 Co linear DV Vertical Termination Cap 948 305 3 Flex 35 ft 946 563 Coaxial to Co linear Adapter Kit 510 994 Rigid Pipe Adapter 58dva E45 4...

Отзывы: