background image

8

Regency Horizon™ HZ40E-2 Gas Fireplace

INSTALLATION

11)

     U n d e r   n o   c i r c u m s t a n c e   s h o u l d   t h i s 

appliance be modified.  Parts that have 
to be removed for servicing should be 
replaced prior to operating this appliance. 
    

12)

 Installation and any repairs to this appliance 

should be done by a qualifi ed service person. 
A professional service person should be called 
to inspect this appliance annually. Make it a 
practice to have all of your gas appliances 
checked annually.

13)

 Do not slam shut or strike the glass door.

14)

 Under no circumstances should any solid fuels 

(wood, paper, cardboard, coal, etc.) be used in 
this appliance.

15)

 The appliance area must be kept clear and free 

of combustible materials, (gases and other fl am-
mable vapours and liquids).

Emissions from burning  wood or gas could 
contain chemicals known to the State of 
California to  cause cancer, birth defects or 
other reproductive harm.

IMPORTANT MESSAGE  

SAVE THESE 

INSTRUCTIONS

The Gas Fireplace must be installed in accordance 
with these instructions. Carefully read all the 
instructions in this manual fi rst. Consult the "authority 
having jurisdiction" to determine the need for a permit 
prior to starting the installation. It is the responsibility 
of the installer to ensure this fi replace is installed 
in compliance with manufacturers instructions and 
all applicable codes.

BEFORE YOU  START

Safe installation and operation of this appliance 
requires common sense, however, we are required 
by the Canadian Safety Standards and ANSI 
Standards to make you aware of the following:

CLOTHING OR OTHER FLAMMABLE 
MATERIAL SHOULD NOT BE PLACED 
ON OR NEAR THE APPLIANCE.

   

CHILDREN AND ADULTS SHOULD BE 
ALERTED TO THE HAZARDS OF HIGH 
SURFACE TEMPERATURES,  ESPE-
CIALLY THE FIREPLACE GLASS, AND 
SHOULD STAY AWAY TO AVOID BURNS 
OR CLOTHING IGNITION.  

GENERAL SAFETY 

INFORMATION

1)

  The appliance installation must conform with 

local codes or, in the absence of local codes, with 
the current Canadian or National Gas Codes, 
CAN1-B149 or ANSI Z223.1 Installation Codes.

2)

  The appliance when installed, must be 

electrically grounded in accordance with local 
codes, or in the absence of local codes with the 
current National Electrical Code, ANSI/NFPA 70 
or CSA C22.1 Canadian Electrical Code.

3)

  See general construction and assembly 

instructions. The appliance and vent should be 
enclosed.

4)

  This appliance must be connected to the 

specifi ed vent and termination cap to the outside 
of the building envelope. Never vent to another 
room or inside a building. Make sure that the 
vent is fi tted as per Venting instructions.

5)

  Inspect the venting system annually for blockage 

and any signs of deterioration.   

6)

  Venting terminals shall not be recessed into a 

wall or siding.

7)

  Any safety glass removed for servicing must be 

replaced prior to operating the appliance.

8)

  To prevent injury, do not allow anyone who is 

unfamiliar with the operation to use the fi replace.

9)

  Wear gloves and safety glasses for protection 

while doing required maintenance.

10)

 Be aware of electrical wiring locations in walls 

and ceilings when cutting holes for termination.

INSTALLATION AND REPAIR SHOULD 
B E   D O N E   B Y   A N   AU T H O R I Z E D 
SERVICE PERSON. THE APPLIANCE 
SHOULD BE INSPECTED BEFORE 
USE AND AT LEAST ANNUALLY BY A 
PROFESSIONAL SERVICE PERSON. 
MORE FREQUENT CLEANING MAY 
BE REQUIRED DUE TO EXCESSIVE 
LINT FROM CARPETING, BEDDING 
MATERIAL, ETC. IT IS IMPERATIVE THAT 
CONTROL COMPARTMENTS, BURNERS 
AND CIRCULATING AIR PASSAGEWAYS 
OF THE APPLIANCE BE KEPT CLEAN.

DUE TO  HIGH TEMPERATURES, THE 
APPLIANCE SHOULD BE LOCATED 
OUT OF TRAFFIC AND AWAY FROM 
FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS 
APPLIANCE CORRECTLY WILL VOID 
YOUR WARRANTY AND MAY CAUSE A 
SERIOUS HOUSE FIRE.

YOUNG CHILDREN SHOULD BE CARE-
FULLY  SUPERVISED WHEN THEY ARE 
IN THE SAME AREA AS THE APPLI-
ANCE.  TODDLERS, YOUNG CHILDREN 
AND OTHERS MAY BE SUSCEPTIBLE 
TO ACCIDENTAL CONTACT BURNS.  A 
PHYSICAL BARRIERS IS RECOMMEND-
ED IF THERE ARE AT RISK INDIVIDUAL 
IN THE HOUSE.  TO RESTRICT ACCESS 
TO A FIREPLACE OR STOVE, INSTALL 
AN ADJUSTABLE SAFETY GATE TO 
KEEP TODDLERS, YOUNG  CHILDREN 
AND OTHER AT RISK INDIVIDUALS OUT 
OF THE ROOM AND AWAY FROM HOT 
SURFACES. 

Содержание Regency Horizon HZ40E-LP2

Страница 1: ...switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire dep...

Страница 2: ...not prohibited by local codes This Direct Vent System Appliance must be installed in accordance with the manufacturer s installation instructions and the Manufactured Home Construction and Safety Stan...

Страница 3: ...f a fireplace at the flick of a switch The model HZ40E has been approved by Warnock Hersey Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy...

Страница 4: ...h Co Linear Flex System 30 Vertical Terminations 31 Rigid Pipe 4 x 6 5 8 31 Venting Arrangements Vertical Terminations 33 Unit Installation with Horizontal Termination 34 Unit Installation with Horizo...

Страница 5: ...e Calorifique 11 WC 2 73 kpa WC C E 25 500 Btu h 7 47kW 10 2 49kPa 53 DMS 0 4500 ft pi 0 1372m 21 000 Btu h 6 15 kW Minimum supply pressure Manifold pressure Orifice size Maximum input Altitude Minimu...

Страница 6: ...tly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIREC...

Страница 7: ...gency Horizon HZ40E 2 Gas Fireplace 7 DIMENSIONS 31 49 5 16 4 45 5 8 36 4 39 13 16 1 13 1 42 16 7 8 18 5 16 16 1 2 1 7 16 33 3 16 10 1092mm 972mm 522mm 902mm 318mm 388mm 15 1 4 600mm 1238mm 914mm 327m...

Страница 8: ...CAN1 B149 or ANSI Z223 1 Installation Codes 2 The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the currentNationalElectr...

Страница 9: ...on fully explained to customer LOCATING YOUR GAS FIREPLACE 1 When selecting a location for your fireplace ensure that the clearances are met 2 The appliance must be installed on a flat solid continuou...

Страница 10: ...d vent system be installed only in accordance with these instructions Clearance Dimension Measured From A Mantel Height min 17 330mm Top of Fireplace Opening B Sidewall on one side 8 203mm Side of Fir...

Страница 11: ...re the paint that is used on the mantel and the facing is high quality or the paint may discolour MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram Combustible Material 2 12 6 4 8...

Страница 12: ...ove 8 screws to remove access panel 3 Easier access to gas connection with panel removed 4 Install any optional components with access panel removed 5 Reinstall access panel with 8 screws and lower fr...

Страница 13: ...3 7 16 596mm Vertical rise terminating horizontal D Minimum Height to Combustibles 43 7 8 1004mm E Corner Wall Depth 57 3 8 1457mm F Corner Facing Wall Width 81 1 8 2061mm G Vent Centerline Height 36...

Страница 14: ...tage junction box to the framing at desired location within 10 ft from fireplace 2 Feed the 12 pin connector through the opening at back of junction box 3 Connect the 12 pin connector to the back of t...

Страница 15: ...r the first coat This product can be found at any hardware store Mud must be cured as per manufacturer s recommendations 6 Prime wall for a second time for proper adhesion of paint 7 Paint walls using...

Страница 16: ...tandoffs and the stove base 4 Non combustible material ie tile slate etc may be brought up to and overlap the unit top and bottom ensuring that the maximum thickness does not go beyond the 1 1 2 as sh...

Страница 17: ...s at the 1 1 2 edge of the flange Finished Material Nailing Strip Position 1 2 1 1 1 2 1 1 2 0 flush Unit Nailing Strip 1 Forward Unit Nailing Strip Forward Unit Nailing Strip Flush w unit Factory Set...

Страница 18: ...ded above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other ap...

Страница 19: ...N A Adjustable Length 3 10 Galvanized N A N A N A 4DAL N A TC 4DLT Adjustable Length 3 10 Black N A N A N A 4DALB N A TC 4DLTB Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A Adjustable Lengt...

Страница 20: ...36 N A N A N A N A N A TM 4ST36 Basic Horizontal Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK N A Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK N A Vert...

Страница 21: ...cated in the venting arrangements diagrams refer to the following instructions 1 Remove the glass door see instructions in this manual 2 Remove the screws that hold the vent restrictor plate in place...

Страница 22: ...lbow at the flue collar when using rigid venting Note Must use optional rigid pipe adapter Part 510 994 when using Rigid Pipe Venting Systems Maintain clearances to combustibles as listed in Clearance...

Страница 23: ...X 6 7 8 These venting systems in combination with the HZ40E Direct Vent Gas Fireplace has been tested and listed as a direct vent heater system by Warnock Hersey Intertek The location of the terminati...

Страница 24: ...d Pipe Adaptor in conjunction withDuraventDirect Vent SelkirkDirect Temp Ameri Vent Direct Venting ICC Excel Direct and Security Secure Vent systems Use of these systems with the Rigid Pipe adaptor is...

Страница 25: ...the starting 45o elbow at the flue collar when using rigid venting 2 Minimum distance between elbows is 1 ft 305mm Maintain clearances to combustibles as listed in the Clearances section Horizontal ve...

Страница 26: ...t with minimum of 11 feet total vertical and maximum 9 feet total horizontal P l e a s e n o t e minimum 1 foot between90o elbows is required A 1 Max 1 Min 3 Max B 2 Max 3 Min 5 Max C 3 Max 5 Min 6 Ma...

Страница 27: ...aximum total pipe length is 28 feet with minimum of 12 feet total vertical and maximum 9 feet total horizontal P l e a s e n o t e minimum 1 foot between 90o elbows is required A 2 Min 1 Max 3 Min 4 M...

Страница 28: ...ra Vent Direct Vent American Metal Products Ameri Vent Direct Vent Security Secure Vent ICC Excel Selkirk Direct Temp AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd...

Страница 29: ...he Clearances section Horizontal vent must be supported every 3 feet Firestopsarerequiredateachfloorlevelandwhenever passing through a wall Must use optional rigid pipe adaptor Part 510 994 when using...

Страница 30: ...ations Section for minimum and maximum heights Required Parts Part Description 946 529 Co linear DV Vertical Termination Cap 948 305 3 Flex 35 ft 946 563 Co Axial to Co Linear Adapter Kit whichcontain...

Страница 31: ...ng with Two 2 90o Elbows For additional vertical venting with 2 x 90o elbows refer to Rigid Pipe Venting Arrangements Section One 90o elbow Two 45o elbows Option V H V V1 With these options maximum to...

Страница 32: ...se options max total pipe length is 30 feet with min of 11 feet total vertical and max 7 feet total horizontal Please note min 1 foot between 90o elbows is required Option V H H1 V V1 A 2 Min 3 Max 4...

Страница 33: ...Distance Feet Vertical Height feet Vent Restrictor Set 2 Vent Restrictor Vent Restrictor V Vent Restrictor Set 2 Set 1 16 Max Vent 8 2 4m Min Horizontal Distance Feet Vertical Height feet 2 51mm max...

Страница 34: ...adapter over the existing inner and outer flue collar Fasten to the outer collar only with the 3 supplied screws drilling pilot holes will make this easier 4 Level the fireplace and fasten it to the...

Страница 35: ...ination cap faces up there are markings on the cap indicating which way is up This will position the termination cap with proper down slope for draining water Fasten the cap to the outer wall with the...

Страница 36: ...fully twist locked position and sealed 5 Cut a hole in the roof centered on the small drilled hole placed in the roof in Step 2 The hole shouldbeofsufficientsizetomeettheminimum requirements for clear...

Страница 37: ...notover tighten HIGH ELEVATION This unit is approved for altitude 0 to 4500 ft CAN1 2 17 M91 GAS LINE INSTALLATION Since some municipalities have additional local codes it is always best to consult wi...

Страница 38: ...the female end tagged DC Supply on wiring harness in unit 2 Locate FCM COM connector on the Remote wire harness see manual for location in unit 3 Plug in wire adaptor to FCM COM connector be careful...

Страница 39: ...Proflame System Configuration 886 GTMF Wire Diagram SureFire Switch 885 Optional AC Adaptor WIRING DIAGRAM This heater does not require a 120V A C supply for operation In case of a power failure the...

Страница 40: ...disc normally open 120V AC 60 Hz White Black Black Ground Fan Fan Proflame System Configuration 886 GTMF Wire Diagram SureFire Switch 885 CAUTION Labelallwirespriortodisconnection whenservicingcontrol...

Страница 41: ...x Speed Control Switch with lead wires Regency Wire Nuts Wire Nuts 14 AWG wire 14 AWG wire Wire Clamp Receptacle Box inside stove Receptacle dedicated use by stove fan only 120 Volts 60 Hz Copper Grou...

Страница 42: ...OFF fan control with 3 stage adjustment Requires a fan if not included to be installed for fan function to operate Must also chose one of the following which enables the flame to be turned down using...

Страница 43: ...allation in the installation manual 5 Remove the burner tray cover by lifting up and out as shown below Prior to removing burner remove crystals pebbles spa stones and inner panels if installed 2 Remo...

Страница 44: ...ws see locations below 8 Once the top panel is removed the left side panel will be accessible Remove 3 screws from the left side access panel in locations shown below Note Some components have been re...

Страница 45: ...receiver as well as operating instructions 14 Reverse steps 2 1 for new installations Reverse steps 8 1 for existing installations 12 Plug the fan power cord into the fan control module in the outlet...

Страница 46: ...e other open spade one the thermodisc Connect the other end of the red wire to the black wire from the fan motor 7 Connect the white wire from the fan motor to the black wire on the power cord dark bl...

Страница 47: ...uld be at the top see page 41 for wiring diagram Unit must be grounded at all times Do not cut the ground terminal off under any circumstances 1 Shut off the gas and power supply to the unit 3 Remove...

Страница 48: ...aneouver fan through left access panel opening 12 Reverse steps 9 1 to complete install 11 To complete fan installation follow steps 2 7 on previous page NOTE The right access panel wasremoved to allo...

Страница 49: ...t Use care not to scratch or mar the panel on the pilot shield Final Install 3 Remove installed factory panels Loosen 2 screws do not remove on panel clip securing side panel Slide panel clip down awa...

Страница 50: ...e fireplaces Use of any other type of pebbles glass crystals or other material can create a danger and will void the warranty BURNER PACKAGES Unit Glass Crystals Stones Spa Ceramic Volcanic E18 5lbs 5...

Страница 51: ...PTO30 PTO60 Plateau Series Glass Crystals shown on Burner and Firebox Floor For Units HZI390E HZI540E DO NOT block pilot area with glass crystals Optional Spa Stones Glass Crystals shown on burner For...

Страница 52: ...oroomtemperature 2 Remove flush glass door see manual 3 Carefully remove the logs from the packaging and unwrap them The logs are fragile handle with care never force into position 4 Ensure glass crys...

Страница 53: ...ece on firebox floor as shown 16 Place Right Log piece on firebox floor as shown 17 If desired install additional crystals on firebox floor in and around installed logs 18 Install lava embers spread e...

Страница 54: ...the door towards the unit Diagram 1 Note Be careful that the glass gasket does not roll up there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit Se...

Страница 55: ...ft side and right side as shown 3 Install mesh screen flush side facing out 4 Install left side and right side top mounting clips approximately 3 from each side NOTE Clips should line up with the edge...

Страница 56: ...1 2 Important 1 2 gap required between faceplate and finished wall when using part 256 924 256 926 256 927 4 pc faceplate 1 If installing optional mesh glass guard See optional Mesh Glass Guard insta...

Страница 57: ...d right side mounting brackets into the mounting slots at the side of the firebox as shown below It is recommended that you use the first mounting slot the one closest to the door frame overlay out of...

Страница 58: ...he burner tray is positioned directly under the burner and is made of a different gauge material from the rest of the firebox and body Therefore the varyingthicknessesofsteelwillexpandandcontract at s...

Страница 59: ...nt alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualifi...

Страница 60: ...damaged or broken glass WARNING Do not operate the appliance with the glass panels removed cracked or broken Replacement of the glass panels should be done by a licensed or qualified service person G...

Страница 61: ...e see instruction in this manual 5 Remove the inner panels reverse of Inner panel Installation in this manual 6 Remove the burner tray cover by lifting up and out as shown below Prior to removing burn...

Страница 62: ...256 530 Burner Assembly LP c w Cap HZ40E 5 904 345 Orifice 53 LP 904 593 Orifice 40 NG Part Description 6 911 024 Valve NG 880 SIT IPI 911 025 Valve LP 880 SIT IPI 7 911 006 Pilot Assembly IPI NG 911...

Страница 63: ...round Pure Black 256 953 Verona Glass Surround Classic Grey 256 955 VeronaGlassSurroundChocolateBrown 256 917 Fan Kit 256 929 Mesh Guard 256 930 Log Set Part Description 946 700 GT Remote Control 946...

Страница 64: ...64 Regency Horizon HZ40E 2 Gas Fireplace NOTES...

Страница 65: ...Regency Horizon HZ40E 2 Gas Fireplace 65 NOTES...

Страница 66: ...66 Regency Horizon HZ40E 2 Gas Fireplace NOTES...

Страница 67: ...rned to the distributor or agent Transportation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an...

Страница 68: ...________________________________________________ Phone ___________________________________________________________ Date Installed ______________________________________________________ Serial No _____...

Отзывы: