12
|
LRI4E / HRI4E Direct Vent Gas Insert
|
12
installation
Diagram 1
Diagram3
Diagram 2
Note: A 3-1/2" mantel delector to reduce
mantel height to 32" from bottom of unit
@ 1"depth.
A noncombustible mantel may be
installed at a lower height if the framing
is made of metal studs covered with a
noncombustible board.
Note: All material used must be completely
non-combustible.
MINIMUM CLEARANCES TO COMBUSTIBLES
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
decorative gas appliance be installed only in accordance with these instructions.
Clearance:
Dimension
Measured From:
A: Sides
6" / 152 mm
From inside edge of faceplate / doors
B: Ceiling
60" / 1524 mm
From Base of Unit
C: Mantel (Min. Height)
*
32" / 813mm
35"/ 889mm
From Base of Unit
From Base of Unit
D:Min. Hearth Depth
14" / 356mm
E: Min. Hearth Length
40"/ 1016mm
G: Max. Mantle Depth
0
-
12" / 305 mm
@ 44" (1118mm) from bottom of unit
K: Min. Alcove Width
54" / 1372 mm
L: Max. Alcove Depth
36" / 914 mm
M: Mantel Deflector
3-1/2"/ 89mm
NOTE: 40” (1016 mm) wide x 14” (356mm) deep hearth is required, unless the unit is raised
6” (152 mm) off the floor surface.
*An optional 3-1/2" deflector, reduces the mantel height to 32" from bottom of unit
@ 1"depth.
Door
Opening
15" Min
From Top of
24
26
28
30
32
34
36
38
0
2
4
6
8
10
12
14
16
18
20
22
24
Allowable
Mantel Area
35"
From bottom
of unit
22
20
18
16
14
Door
Opening
12" Min
From Top of
24
26
28
30
32
34
36
38
0
2
4
6
8
10
12
14
16
18
20
22
24
Allowable
Mantel Area
32"
From bottom
of unit
22
20
18
16
14
12
MANTEL CLEARANCES WITHOUT DEFLECTOR
MANTEL CLEARANCES WITH 3-1/2" DEFLECTOR
WARNING
Although this appliance passes safety
certiication, the hearth in front of the ireplace
becomes very hot when the ireplace heats. Do
not use the hearth as a seat or shelf.
Содержание Liberty LRI4E-LP
Страница 5: ...LRI4E HRI4E Direct Vent Gas Insert 5 5 dimensions UNIT DIMENSIONS WITH LOW PROFILE FACEPLATE...
Страница 6: ...6 LRI4E HRI4E Direct Vent Gas Insert 6 dimensions UNIT DIMENSIONS WITH 4 SIDED VIGNETTE FACEPLATE...
Страница 54: ...54 LRI4E HRI4E Direct Vent Gas Insert 54 parts list 12...
Страница 60: ......
Страница 61: ...LRI4E HRI4E Direct Vent Gas Insert 61 61 notes...
Страница 62: ...62 LRI4E HRI4E Direct Vent Gas Insert 62 notes...
Страница 63: ......