GAS CONNECTION
GAS CONNECTION WARNING:
Only persons licensed to work with
gas piping may make the necessary
gas connections to this appliance.
1)
If the appliance is to be installed into an
existing chimney system, thoroughly clean
the masonry or factory built fi replace.
2)
The gas connection is 12" BSP.
3)
Locate the center point where the fl ue will
pass through the chimney above the appli-
ance. Move the appliance into the exact
location where it is to be installed. Ensure
that the Insert is level.
4)
The installer must provide a valve with a
plugged tapping, accessible for test gauge
connection, immediately upstream of the
gas supply connection to the appliance.
CAUTION: If the glass is removed or opened
for servicing, it must be replaced and closed
prior to operating the appliance. The glass
must be fi xed in the door when operating.
SPECIFICATIONS
INSTALLATION
NOTE: Mantel clearances for Installation into
a Zero Clearance Kit are different.
Please refer to the Zero Clearance
Kit Manual for details.
Mantel Clearances with
Bay and Flush Louvres in
Masonry Installation
MINIMUM FIREPLACE
DIMENSIONS
The minimum fi replace dimensions for the
Regency gas space heater are shown in the
following diagrams:
Note: A non-combustible mantel may be
installed at a lower height if the fram-
ing is made of metal studs covered
with a non-combustible board.
Note: A minimum of 38mm must be main-
tained for the rear of the unit and the
rear of the fi replace to ensure correct
operation of down draught divert.
Ensure the standoff tabs at the rear
of the unit are in position.
MINIMUM
CLEARANCES TO
COMBUSTIBLES
The minimum fi replace clearances for the
Regency gas space heater are shown in the
following diagrams:
From Unit
Sides
A
255 mm
Ceiling
B
1205 mm
Mantle
C
see Mantel
Clearances
From Surround
(660 mm x 1016 mm)
Max. Mantle Depth
G
305 mm
Hearth Height
H
0 mm
Hearth Depth
I
405
mm
Hearth Width
J
1015
mm
Min. Alcove Width
K
1220 mm
Max. Alcove Depth
L
915
mm
NG
LPG
INJECTOR #37
#52
SIZE 2.65mm
1.6mm
INPUT
Min. 17 mj/h
Min. 17 mj/h
RATING
Max. 31 mj/h
Max. 31 mj/h
MANIFOLD
PRESSURE Max. 0.9 kPa Max. 2.59 kPa