18
Regency I31-3 Gas Fireplace Inbuilt
CAUTION: ANY SAFETY SCREEN
OR GUARD REMOVED FOR SERV-
ICING AN APPLIANCE MUST BE
REPLACED PRIOR TO OPERATING
THE APPLIANCE.
CLOTHING OR OTHER FLAMMA-
BLE MATERIAL SHOULD NOT BE
PLACED ON OR NEAR THE APPLI-
ANCE.
6)
Each time the appliance is lit, it may cause
condensation and fog the glass. This con-
densation and fog is normal and will disap-
pear in a few minutes as the glass heats up.
Never operate the appliance without the
glass properly secured in place, with
broken glass or with the door open.
7)
Verify proper operation after servicing.
8)
Periodically check the pilot fl ames, there
should be three strong blue fl ames approx.
3/4" long - 1 fl ame to the front burner, and
1 to the thermopile and one to the left. See
diagrams below.
Top View of pilot fl ame
Correct fl ame pattern has two strong blue
fl ames: 1 fl owing around the thermopile and
1 reaching towards the rear burner (it does
not have to be touching the burner).
Top View of pilot fl ame
Incorrect fl ame pattern will have small, prob-
ably yellow fl ames, not coming into proper
contact with the rear burner or thermopile.
MAINTENANCE
If you have an incorrect fl ame pattern,
contact your Regency dealer for further
instructions.
GOLD-PLATED TRIM
The 24 carat gold plated fi nish on the trim
requires little maintenance, and need only be
cleaned with a damp cloth. DO NOT use abrasive
materials or chemical cleaners, as they may
harm the fi nish and void the warranty.
Clean any fi ngerprints off before turn-
ing the unit on. If the top louvres start to
discolour, check the door gasket seal and
replace if necessary.
LOG REPLACEMENT
The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door to carefully remove the logs.
The pilot light generates enough heat to burn
someone. If for any reason a log should need
replacement, you must use the proper replace-
ment log. The position of these logs must be as
shown in the diagram under Log Installation.
NOTE: Improper positioning of logs may
create carbon build-up and will alter
the unit’s performance which is not
covered under warranty.
WARNING
Do not spray aerosols in the
vicinity of this appliance while
in operation.
DOOR GLASS
REPLACEMENT
Your Regency stove is supplied with high tem-
perature, 5 mm Neoceram ceramic glass that
will withstand the highest heat that your unit will
produce. In the event that you break your glass
by impact, purchase your replacement from an
authorised Regency dealer only, and follow our
step-by-step instructions for replacement.
WARNING: do not operate appli-
ance with the glass front removed,
cracked or broken. Replacement
of the glass should be done by
a licensed or authorised service
person.
Bay Glass Removal
1)
Remove the door from the unit and place on
a soft surface to prevent scratching.
2)
Remove the nuts holding the glass retainers
in place.
3)
Remove the glass retainers (sides, top and
bottom).
4)
Replace the glass.
The glass must have
gasketing around it.
5)
Reverse the previous steps, replace the
retainers and fasten with the nuts but do not
over tighten, as this can break the glass.
6)
Replace door on the stove and check the
seal.
Flush Glass Replacement
Slide old glass out of the side frames and
replace with new glass.