22 |
LRI3E-11 / HRI3E-11 Direct Vent Gas Insert
installation
1.
Detach the Flue Connector Plate from the unit by removing the
Connector Plate Screws and sliding the Flue Connector Plate forward
and off the unit.
NOTE:
Flue Plate Connector Gasket
must not be damaged or removed.
Care must be taken to ensure that this
gasket remains intact to prevent flue
leakage.
5. When the Flue Connector Plate is close to the front of the unit, engage
the Flue Connector Screws and carefully tighten the Flue Connector
Plate the final amount.
** Make sure the Rear Tab connects into the slot in the Flue Connector
Plate. Failure to do so will result in flue gas leakage and degrade the
operation of the unit ** (See diagram below of location.)
The Flue connection is complete when the Flue Connector Plate is fully
forward and the Rear Tabs are fully engaged.
6. Remove the Flue Connector Tool and store for future use.
2. Attach the Flue Liners onto the Flue Connector Plate using non RTV
type sealant, then fasten with 3 screws.
See the section in this manual on Venting installation.
3. Position the unit in front of the fireplace opening, start the Flue Connec-
tor Plate into the Flue Connector Plate Guides.
Flue Connector Slide Tool
Tab connected correctly
Flue Connector Plate
Connector Plate Screws
4. Use the Flue Connector Slide Tool to slowly pull the Flue Connector Plate
forward as you move the Insert rearward into the Fireplace Chase.
FLUE / VENT INSTALLATION
WARNING:
Failure to position the parts in accordance with these diagrams or failure
to use only parts specifically approved with this appliance may result in
property damage or personal injury.
Connecting the Vent Liners
Intake Liner
Exhaust Liner
Flue Connecter
Plate