LRI3E-11 / HRI3E-11 Direct Vent Gas Insert
| 21
installation
Remove connector plate guide
Vent restrictor install
The LRI3E-11/HRI3E-11 use a heat exchanger and efficient combustion
technology to provide extreme heating efficiencies. The more efficient an
appliance becomes, the lower the flue gas temperatures becomes.
On start-up, flue temperatures are required to initiate venting action.
Here are some considerations when setting up the LRI3E-11/HRI3E-11:
When operating the unit in temperatures below 50°F/10°C, run the pilot in
"Standing Pilot" mode, 1. Press and hold the small flame icon on the hand
held remote control to set the appliance at continuous pilot.
Note: If after 7 days the appliance has not had a call for heat, the pilot will
extinguish and will not be present. To enable pilot operation you will need to
repeat steps for continuous pilot operation.
STANDING PILOT
ALTERNATE APPROVED CAPS/ADAPTOR
tooltip
Flue connector
plate guide
tooltip
Restrictor
plate
VENT RESTRICTOR PLATE INSTALLATION
46DVA-GK 3" Co-linear Adaptor with flashing
46DVA-VC Vertical Termination Cap
or
46DVA-VCH High Wind Cap
* 948-417/P 2” to 3” Increaser (Air inlet)
*Note : The 46DVA-GK Co-linear Adaptor with flashing comes with 2 - 3” col-
lars. The increaser is required to adapt the flex (air inlet side) which is 2 inch
to the 46DVA-GK Co-linear Adaptor with flashing.
The optional 2"-3" increaser for the air inlet must be affixed at the termination
end between the 2" liner and the 46DVA-GK Co-linear Adaptor with flashing.
This must not be affixed to the appliance stove collar.
In areas of consistently high winds, we recommend using the Simpson Dura-
Vent System (46DVA-GK adapter and 46DVA-VCH high-wind cap). The Air
Intake pipe must be attached to the inlet air collar of the termination cap.
This chimney system is also ideal when the chimney termination is round in
applications where this appliance is being installed into a factory built fireplace.
Note: only installed on runs at the minimum 8 feet vent height from above unit.
If longer than 8 feet the restrictor is not required.
1. Remove flue connecter plate by sliding out toward the back of the unit - see
next page.
2. Remove left flue connector plate guide by removing 2 screws as shown below.
3. Flip the flue connector plate gasket to the right (out of the way) to allow ease
of installation of the vent restrictor.
4. Install vent restrictor with 2 screws in location shown below.