LRI3E-11 / HRI3E-11 Direct Vent Gas Insert
| 27
installation
920-032
01.15.19
2
LRI3E / HRI3E
12. Attach the label “This unit has been converted to LPG” near or on top of
the serial # decal.
13. Replace red “NG” label with yellow “LPG” label.
14. Adjust aerations settings:
LRI3E = 1/4" (6 mm)
HRI3E = 5/16" (8 mm))
NOTE:
In higher elevations, air shutter settings may have to be opened
more to compensate.
The minimum air settings noted for the HRI3E are good for both media and
driftwood log set.
15. Reinstall burner removed in Step 7.
16. Check for gas leaks.
17. Check inlet and outlet pressures. See Gas Pipe Pressure Testing in manual.
18. Reverse steps 2-1 to reassemble unit.
19. Check operation of flame control.
Installer Notice:
These instructions must be left
with the appliance
.
10. Remove burner orifice with a 1/2" wrench. Use another wrench to hold
onto the elbow behind the orifice. Recycle orifice.
11. Reinstall new burner orifice LPG stamped #55 and tighten.
Burner orifice
8. From inside the firebox, remove pilot retainer clip with pliers and pull off the
pilot cap to expose the pilot orifice.
HRI3E
HRI3E - Remove the burner by removing 5 screws in locations shown below
to remove burner cover and 2 screws to remove burner (shown below).
tooltip
burner cover
burner
9. Unscrew the pilot orifice with the Allen key; then replace with the LPG
pilot orifice and the pilot cap, provided in the kit.
Pilot retainer clip