background image

6    | 

H2104 / I3104  Wood Insert

6    |

installation

CHIMNEY  
SPECIFICATIONS

Before installing, check and clean your chimney 

system thoroughly. If in doubt about its condi-

tion, seek professional advice. Your Regency 

Insert is designed for installation into a masonry 

fireplace that is constructed in accordance with 

the requirements of "The Standard for Chimneys, 

Fireplaces, Vents, and Solid Fuel Burning Ap

-

pliance",  N.F.P.A.  211,  the  National  Building 

Code of Canada, or the applicable local code 

requirements.  

The appliance, when installed, must be electri-

cally grounded in accordance with local codes or, 

in the absence of local codes, with the National 

Electrical Code, ANSI/NFPA 70, or the Canadian 

Electrical code, CSA C22.1.

Regency Inserts are designed to use either a 

5.5" (140mm) or 6" (152mm) flue.

Requirements for Installing 
Solid-fuel Inserts in Factory-built 
Fireplaces.

1)

  The insert must be tested and meet the 

requirements of UL 1482 (U.S.) and or ULC 

S628 (Canada) when tested in a masonry 

fireplace built per ULC S628.

2)

  The factory-built fireplace must be listed per 

UL 127 or ULC S610.

3)

  Clearances obtained from the masonry fire

-

place tests are also relevant for installation 

in factory-built fireplaces.

4)

  Installation must include a full height listed 

chimney liner type HT requirements (2100 

degree  F.)  per  UL  1777  (U.S.)  or  ULC 

S635 (Canada). The liner must be securely 

attached  to  the  insert  flue  collar  and  the 

chimney top.

5)

  Means must be provided to prevent room 

air passage to the chimney cavity of the 

fireplace.  This  may  be  accomplished  by 

sealing the damper area around the chimney 

liner, or sealing the fireplace front.

6)

  Alteration of the fireplace in any manner is not 

permitted with the following exceptions; 

 

a. 

  external trim pieces which do not affect 

the operation of the fireplace may be 

removed providing they can be stored 

on or within the fireplace for re-assembly 

if the insert is removed.

 

b.

   the chimney damper may be removed 

to install the chimney liner.

7)

  Circulating air chambers (i.e. in a steel 

fireplace liner or metal heat circulator) shall 

not be blocked.

8)

  Means must be provided for removal of the 

insert to clean the chimney flue.

Regency Inserts are constructed with the high-

est quality materials and assembled under strict 

quality control procedures that insure years of 

trouble free and reliable performance.

It is important that you read this manual thor-

oughly and fully understand the safe instal-

lation and operating procedures.  The more 

you understand the way your Regency Insert 

operates, the more enjoyment you will experi-

ence from knowing that your unit is operating 

at peak performance.

BEFORE INSTALLING 
YOUR INSERT

1)

  Read all instructions before installing and 

using your fireplace insert.  Install and use 

only  in  accordance  with  manufacturer’s 

installation and operating instructions.

2)

  Check your local building codes - Building 

Inspection Department.  You may require 

a  permit  before  installing  your  insert.  Be 

aware that local codes and regulations may 

override some items in the manual.

  WARNING:  Careless installation is the 

major cause of safety hazard.  Check all 

local building and safety codes before 

installation of unit.

3)

  Notify your home insurance company that 

you plan to install a fireplace insert or hearth 

heater.

4) 

Your fireplace insert is heavy and requires 

two or more people to move it safely.  The 

insert can be badly damaged by mishan-

dling.

5)

  If  your  existing  fireplace  damper  control 

will become inaccessible once you have 

installed your Regency Insert, you should 

either remove or secure it in the open posi-

tion.

6)

  Inspect  your  fireplace  and  chimney  prior 

to installing your insert to determine that it 

is free from cracks, loose mortar or other 

signs of damage. If repairs are required, 

they should be completed before installing 

your insert.  Do not remove bricks or mortar 

from your masonry fireplace.

7)

  Do not connect the insert to a chimney 

system servicing another appliance or an 

air distribution duct.

9)

  Inserts that project in front of the fireplace 

must be supplied with appropriate supporting 

means.

10)

 Installer must mechanically attach the sup-

plied label to the inside of the firebox of the 

fireplace into which the insert is installed.

In  order  for  a  solid-fuel  insert  to  be  certified 

for  use  in  factory-built  fireplaces,  the  above 

information must be clearly stated in the instal-

lation manual and appropriate markings. Final 

approval is contingent on the authority having 

jurisdiction.

FIREPLACE  
SPECIFICATIONS

Your  fireplace  opening  requires  the  following 

minimum sizes:

                             Height         Width Depth

Large (I3104L) 

25" 

28"  17"

Hearth Heater (H2104M) 20.0"  -- 

--

Two faceplates are available to seal the fire

-

place opening:

  

 Standard 

Oversize

Large (I3104L)

  44"W x 32"H 

50"W x 34.5"H

Hearth Heater (H2104M)

  40 1/4"W x 30"H 

48"W x 33"H

INSTALLING YOUR   
INSERT

Your insert is very heavy and will require two 

or three people to move it into position. The 

insert can be made a little lighter by removing 

the cast iron door by opening it and lifting it 

off its hinges. Be sure to protect your hearth 

extension with a heavy blanket or carpet scrap 

during the installation.

Convection Grills for 
I3104L 

The convection grills are installed 

before

 the 

unit is positioned inside the fireplace.

Position the grill on the inside bodyface side 

and fasten using the bolts, washers and nuts 

provided (2 per side) as shown in the diagrams.  

Note:  The grill has a front and rear, the holes 

on the front side have rounded edges 

and the rear holes have flat edges.

Emissions from burning  wood or gas could 

contain chemicals known to the State of Cali-

fornia to  cause cancer, birth defects or other 

reproductive harm.

"

WARNING

: This fireplace has been converted 

for use with a wood insert only and cannot be 

used for burning wood or solid fuels unless 

all original parts have been replaced, and the 

fireplace re-approved by the authority having 

jurisdiction."

Содержание H2104

Страница 1: ...035d MODELS H2104 I3104L WOOD Fireplace Insert Hearth Heater 08 30 16 Owners Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com ...

Страница 2: ...is heater has been shown to deliver heat at rates ranging from 11 900 BTU hr to 42 900 BTU hr This unit has been tested using 5G series and generates the best efficiency when operated using well seasoned wood and installed in the main living areas where the majority of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a mann...

Страница 3: ... Into a Masonry Fireplace 8 Faceplate and Trim 9 Stainless smoke deflector install 10 Fan Blower 11 Floor Protection 12 Firebrick Assembly 12 Door Handle 12 Brick Flue Baffle Secondary Air Tube Installation 12 Draft Control 13 Screen Door 13 OPERATING INSTRUCTIONS First Fire 13 Fan Operation All Units 13 Ash Disposal 13 Some Safety Guidelines 13 Creosote 14 MAINTENANCE Maintenance of Gold Plated D...

Страница 4: ...00L MAIN ASSY I3100 1 1 12 A A 27 1 2 699mm 26 660mm 15 13 16 402mm 10 3 8 263mm 1 7 16 36mm 6 7 8 175mm 44 1118mm 32 813mm 4 15 16 125mm 9 7 16 240mm 6 1 4 159mm 22 7 8 581mm 5 1 2 140mm 6 152mm Collar 952mm 37 1 2 23 1 4 590mm Regular Faceplate Oversize Faceplate is 50 W x 34 1 2 H UNIT DIMENSIONS FOR H2104M CHK DWN BLANK SIZE PART MAT L ANGULAR INSIDE BEND RADII DIMENSIONS TOLERANCES UNLESS OTH...

Страница 5: ...E MADE IN CANADA Duplicate Serial INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER S INSTALLATION AND OPERATING INSTRUCTIONS INSTALL AND USE ONLY IN MASONRY FIREPLACE OR FACTORY BUILT FIREPLACE CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA DO NOT REMOVE THIS LABEL 103 LISTED FACTORY BUILT FIREPLACE INSERT CERTIFIED FOR USE IN CANADA AN...

Страница 6: ...ing codes Building Inspection Department You may require a permit before installing your insert Be aware that local codes and regulations may override some items in the manual WARNING Careless installation is the major cause of safety hazard Check all local building and safety codes before installation of unit 3 Notify your home insurance company that you plan to install a fireplace insert or hear...

Страница 7: ...tcollar Detailedinstallationinstructionsare included with the kit Position the grill on the inside bodyface side and fasten using the bolts washers and nuts provided 2 per side as shown in the diagrams Note Thegrillhasafrontandrear theholes onthefrontsidehaveroundededges and the rear holes have flat edges OPTIONAL FLUE Thermal floor protection is not required if the unit is raised 3 5 minimum meas...

Страница 8: ...s able to breathe better by allowing a greaterdrafttobecreated Thegreaterdraftcan decrease problems such as difficult start ups smoking out the door and dirty glass INSTALLATION INTO A FACTORY BUILT FIREPLACE 1 When installed in a factory built fireplace a full stainless steel rigid or flexible flue liner is mandatory forbothsafetyandperformance purposes When a flue or liner is in use the insert i...

Страница 9: ... time Note It may be easier to install the insula tion faceplate top and faceplate trim withtheunitpulledslightlyawayfrom the fireplace face If this is done be very careful not to disturb the con nector when shifting the unit to its final position Nowthatyourinsertisinstalled checkoncemore that all the clearances from the unit to any com bustible materials are correct as listed earlier slide your ...

Страница 10: ...2 hand tightened bolts To replace the deflector loosen off both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector is installed through the door opening in location shown in diagram Smoke ...

Страница 11: ... least 30 minutes after starting fire Your fan should only be installed once the unit is in place in order to prevent any damage to the fan To attach follow the instructions provided with the fan 1 Align the fan support with the offset clip on the bottom of the ashlip 2 Slidethesupportsintotheclips Thetension holdingtheclipsinplacemaybeadjustedby increasing or decreasing the offset spacing of the ...

Страница 12: ...ilt the first Baffle Brick down and then slide the2ndBaffleBrickupandback Reposition both baffle bricks flat on the air tubes 3 Important push both baffle bricks so they are tight against the side walls 4 Install the third air tube into the holes on the side channels The notch goes on the right hand side with the air holes facing forward toward the door opening If the tube will not slide in easily...

Страница 13: ... your first fire it is important that your fully understand the operation of you draft control The draft rod is on the left side of the Inserts and it controls the intensity of the fire by increasing or decreasing the amount of air allowed into the firebox To increase your draft pull open and to decrease push closed As well as a primary and glass wash air system the unit has a full secondary draft...

Страница 14: ...l WARNING Never build a roaring fire in a cold stove Always warm your stove up slowly 5 Once a bed of coals has been established you may adjust the draft control to a low settingtooperatetheunitinitsmostefficient mode 6 During the first couple of hours keep the combustion rate at a moderate level and avoid a large fire until the paint is cured Only then can you operate the insert at its maximum se...

Страница 15: ...ose draft control 2 Call the Fire Department Ways to Prevent and Keep Unit Free of Creosote 1 Burn insert with draft control wide open for about15minuteseverymorningduringburn ing season This helps to prevent creosote deposits within the heating system 2 Burn insert with draft control wide open for about 10 15 minutes every time you add freshwood Thisallowsthewoodtoachieve the charcoal stage faste...

Страница 16: ... Large Gold 948 135 Spring Handle Large Nickel 20 948 132 Spring Handle Small Gold 948 136 Spring Handle Small Nickel 23 820 235 Flue Brackets Pkg 163 915 I3104L Fan Blower Assembly 24 910 157 P Blower Fan Motor 25 910 678 Power Cord 120 Volts 27 910 142 Fan Thermodisc 28 910 140 Fan Speed Switch HI OFF LOW 3 way 29 910 138 Switch Auto Manual 2 way 30 Grommet Strain Relief 35 063 954 Air Tube 1 I3...

Страница 17: ...t of 3 385 Trim Right Regular 386 Trim Top Regular 387 Trim Left Regular 388 Faceplate Side Regular 389 Faceplate Top Regular 163 912 Faceplate Trim Set Oversize 163 572 Black Trim Oversize Set of 3 395 Trim Right Oversize 396 Trim Top Oversize 397 Trim Left Oversize 398 Faceplate Side Oversize 399 Faceplate Top Oversize Not available as a replacement part ...

Страница 18: ... 120 Volts 25 910 678 Power Cord 120 Volts 27 910 142 Fan Thermodisc 28 910 140 Fan Speed Switch HI OFF LOW 3 way 29 910 138 Switch Auto Manual 2 way 30 Grommet Strain Relief 35 120 954 Air Tube Front 36 120 953 Air Tube Rear 37 836 212 Baffle Insulation 38 Insulation Weights 39 120 950 Steel Baffle 948 216 Regency Logo Faceplate H2104M 120 910 Faceplate Trim Set Regular 120 570 Black Trim Regular...

Страница 19: ...11 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 71 Brick Partial 1 1 4 x 4 x 9 72 Brick Partial 1 1 4 x 1 3 4 x 9 75 Brick Partial 1 1 4 x 4 x 8 3 4 76 Brick Partial 1 1 4 x 2 x 9 78 Brick Partial 1 1 4 x 2 1 4 x 2 1 4 81 Brick Partial 1 1 4 x 1 1 4 x 9 84 Brick Partial 1 1 4 x 4 1 2 x 8 85 Brick Partial 1 1 4 x 4 1 4 x 8 Not available as a replacement part ...

Страница 20: ...wiring switches etc 2 Glass Crazing 1 Catalyst Assembly 6 Years Prorated 3 Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defective during the warranty period as outlined above will be repaired or replaced at FPI s option through an accredited distributor dealer...

Страница 21: ...d mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solvents cardboard coal or coal products oil based products waxed cartons compressed pre manufactured logs lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result ...

Страница 22: ... should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief des...

Страница 23: ...rder for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made i...

Страница 24: ......

Страница 25: ...H2104 I3104 Wood Insert 25 25 notes ...

Страница 26: ...26 H2104 I3104 Wood Insert 26 notes ...

Страница 27: ......

Страница 28: ..._______________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Printed in Canada Regency and Classic are trademarks of FPI Fireplace Products International Ltd Copyright 2016 FPI Fireplace Products International Ltd...

Отзывы: