background image

 

H2104 / I3104  Wood Insert

  |    15

15

maintenance

at regular intervals.  

7)

  Your Regency Insert can be very hot.  You 

may be seriously burned if you touch the 

insert while it is operating. Warn children of 

the burn hazard.

8)

  The insert consumes air while operating,  

provide adequate ventilation with an air 

duct or open a window while the insert is 

in use.

9)

  Do not use grates, irons or other methods 

for  supporting  fuel.  Burn  directly  on  the 

bricks.

10) 

Open the draft control fully for 10 to 15 

seconds prior to slowly opening the door 

when refuelling the fire.

11)

 Do not connect your unit to any air distribu-

tion duct.

12) 

Your insert should burn dry, standard fire

-

wood only. The use of “mill ends” is discour

-

aged as this fuel can easily overheat your 

insert. Evidence of excessive overheating 

will void your warranty.  As well, a large 

portion of sawmill waste is chemically 

treated lumber, which is illegal to burn in 

many areas. Chemically treated fire logs 

also must not be burned in your insert.

13)

 Do not store any fuel closer than 2 feet from 

your unit.

14)

 Do not burn salt drift wood as it will corrode 

your unit and void the warranty.

15)

 Do not operate the unit if the glass is broken 

or missing. Do not operate the unit if the 

gasketing is worn out and not sealing the 

door or the glass.

It is very important to carefully maintain your 

insert, including burning seasoned wood and 

maintaining a clean stove and chimney system.  

Have the chimney cleaned before the burning 

season and as necessary during the season, as 

creosote deposits may build up rapidly.  Moving 

parts of your insert require no lubrication.

CREOSOTE

When wood is burned slowly, it produces tar and 

other organic vapors, which form creosote when 

combined with moisture. The creosote vapors 

condense in the relatively cool chimney flue of a 

slow-burning fire.  As a result, creosote residue 

accumulates on the flue lining. When ignited, 

this creosote can make an extremely hot fire.

Removal for Cleaning etc.

Removal of your insert for cleaning purposes 

is usually not required if a proper installation 

has been done. In the event that removal is re-

quired, be sure not to damage any parts needed 

for re-installation. In most cases removal and 

replacement of the baffle system should allow 

full access for cleaning.

WARNING:   Things to remember in case 

of chimney fire

:

1)  Close draft control

2)  Call the Fire Department

Ways to Prevent and 
Keep Unit Free of Creosote

1)

  Burn insert with draft control wide open for 

about 15 minutes every morning during burn-

ing season.  This helps to prevent creosote 

deposits within the heating system.

2)

  Burn insert with draft control wide open for 

about 10 - 15 minutes every time you add 

fresh wood. This allows the wood to achieve 

the charcoal stage faster and burns up any 

wood vapors which might otherwise be 

deposited within the system.

3)  Only burn seasoned wood!  

Avoid burning 

wet or green wood. Seasoned wood has 

been dried at least one year.

4)

  A  small  hot  fire  is  preferable  to  a  large 

smouldering one that can deposit creosote 

within the system.

5)

  Check the chimney at least twice a month 

during the burning season for creosote 

build-up.

6)

  Have chimney system and unit cleaned by 

competent chimney sweeps twice a year 

during the first year of use and at least once 

a year thereafter or when needed.

DOOR GASKET

If the door gasket requires replacement, 7/8" 

diameter material must be used. A proper high 

temperature gasket adhesive is required. A 

gasket repair kit, Part # 846-570 is available 

from your local Regency dealer.

DOOR LATCH  
ADJUSTMENT

The door latch may require adjustment as the 

door gasket material compresses after a few 

fires.  Removal  of  the  spacer  washer,  shown 

in the diagram below, will allow the latch to 

be moved closer to the door frame, causing 

a tighter seal. Remove and replace the nuts, 

washer as shown.  

GLASS CLEANING

Only clean your glass window when it is cool. 

Your local retailer can supply you with special 

glass cleaner if plain water and a soft cloth does 

not remove all deposits.

GLASS  
REPLACEMENT

Your Regency Insert is supplied with 5 mm. 

Neoceram ceramic glass that will withstand 

the highest heat that your unit will produce. In 

the event that you break your glass by impact 

- purchase your replacement from an authorized 

Regency dealer only, and follow our step-by-step 

instructions.

GLASS REMOVAL

Allow the stove to cool before removing or re-

placing glass. Remove the door from the insert 

and  remove  the  glass  retainer.    Use  caution 

when removing broken glass to prevent injury.

When placing the replacement glass in the 

door, make sure that the glass gasketing will 

properly seal your unit.  Replace the retainer 

and tighten securely, but do not wrench down 

on the glass as this may cause breakage.  Do 

not substitute materials. If your glass door does 

break, do not continue to use your unit until it 

has been replaced.

Содержание H2104

Страница 1: ...035d MODELS H2104 I3104L WOOD Fireplace Insert Hearth Heater 08 30 16 Owners Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com ...

Страница 2: ...is heater has been shown to deliver heat at rates ranging from 11 900 BTU hr to 42 900 BTU hr This unit has been tested using 5G series and generates the best efficiency when operated using well seasoned wood and installed in the main living areas where the majority of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a mann...

Страница 3: ... Into a Masonry Fireplace 8 Faceplate and Trim 9 Stainless smoke deflector install 10 Fan Blower 11 Floor Protection 12 Firebrick Assembly 12 Door Handle 12 Brick Flue Baffle Secondary Air Tube Installation 12 Draft Control 13 Screen Door 13 OPERATING INSTRUCTIONS First Fire 13 Fan Operation All Units 13 Ash Disposal 13 Some Safety Guidelines 13 Creosote 14 MAINTENANCE Maintenance of Gold Plated D...

Страница 4: ...00L MAIN ASSY I3100 1 1 12 A A 27 1 2 699mm 26 660mm 15 13 16 402mm 10 3 8 263mm 1 7 16 36mm 6 7 8 175mm 44 1118mm 32 813mm 4 15 16 125mm 9 7 16 240mm 6 1 4 159mm 22 7 8 581mm 5 1 2 140mm 6 152mm Collar 952mm 37 1 2 23 1 4 590mm Regular Faceplate Oversize Faceplate is 50 W x 34 1 2 H UNIT DIMENSIONS FOR H2104M CHK DWN BLANK SIZE PART MAT L ANGULAR INSIDE BEND RADII DIMENSIONS TOLERANCES UNLESS OTH...

Страница 5: ...E MADE IN CANADA Duplicate Serial INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER S INSTALLATION AND OPERATING INSTRUCTIONS INSTALL AND USE ONLY IN MASONRY FIREPLACE OR FACTORY BUILT FIREPLACE CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA DO NOT REMOVE THIS LABEL 103 LISTED FACTORY BUILT FIREPLACE INSERT CERTIFIED FOR USE IN CANADA AN...

Страница 6: ...ing codes Building Inspection Department You may require a permit before installing your insert Be aware that local codes and regulations may override some items in the manual WARNING Careless installation is the major cause of safety hazard Check all local building and safety codes before installation of unit 3 Notify your home insurance company that you plan to install a fireplace insert or hear...

Страница 7: ...tcollar Detailedinstallationinstructionsare included with the kit Position the grill on the inside bodyface side and fasten using the bolts washers and nuts provided 2 per side as shown in the diagrams Note Thegrillhasafrontandrear theholes onthefrontsidehaveroundededges and the rear holes have flat edges OPTIONAL FLUE Thermal floor protection is not required if the unit is raised 3 5 minimum meas...

Страница 8: ...s able to breathe better by allowing a greaterdrafttobecreated Thegreaterdraftcan decrease problems such as difficult start ups smoking out the door and dirty glass INSTALLATION INTO A FACTORY BUILT FIREPLACE 1 When installed in a factory built fireplace a full stainless steel rigid or flexible flue liner is mandatory forbothsafetyandperformance purposes When a flue or liner is in use the insert i...

Страница 9: ... time Note It may be easier to install the insula tion faceplate top and faceplate trim withtheunitpulledslightlyawayfrom the fireplace face If this is done be very careful not to disturb the con nector when shifting the unit to its final position Nowthatyourinsertisinstalled checkoncemore that all the clearances from the unit to any com bustible materials are correct as listed earlier slide your ...

Страница 10: ...2 hand tightened bolts To replace the deflector loosen off both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector is installed through the door opening in location shown in diagram Smoke ...

Страница 11: ... least 30 minutes after starting fire Your fan should only be installed once the unit is in place in order to prevent any damage to the fan To attach follow the instructions provided with the fan 1 Align the fan support with the offset clip on the bottom of the ashlip 2 Slidethesupportsintotheclips Thetension holdingtheclipsinplacemaybeadjustedby increasing or decreasing the offset spacing of the ...

Страница 12: ...ilt the first Baffle Brick down and then slide the2ndBaffleBrickupandback Reposition both baffle bricks flat on the air tubes 3 Important push both baffle bricks so they are tight against the side walls 4 Install the third air tube into the holes on the side channels The notch goes on the right hand side with the air holes facing forward toward the door opening If the tube will not slide in easily...

Страница 13: ... your first fire it is important that your fully understand the operation of you draft control The draft rod is on the left side of the Inserts and it controls the intensity of the fire by increasing or decreasing the amount of air allowed into the firebox To increase your draft pull open and to decrease push closed As well as a primary and glass wash air system the unit has a full secondary draft...

Страница 14: ...l WARNING Never build a roaring fire in a cold stove Always warm your stove up slowly 5 Once a bed of coals has been established you may adjust the draft control to a low settingtooperatetheunitinitsmostefficient mode 6 During the first couple of hours keep the combustion rate at a moderate level and avoid a large fire until the paint is cured Only then can you operate the insert at its maximum se...

Страница 15: ...ose draft control 2 Call the Fire Department Ways to Prevent and Keep Unit Free of Creosote 1 Burn insert with draft control wide open for about15minuteseverymorningduringburn ing season This helps to prevent creosote deposits within the heating system 2 Burn insert with draft control wide open for about 10 15 minutes every time you add freshwood Thisallowsthewoodtoachieve the charcoal stage faste...

Страница 16: ... Large Gold 948 135 Spring Handle Large Nickel 20 948 132 Spring Handle Small Gold 948 136 Spring Handle Small Nickel 23 820 235 Flue Brackets Pkg 163 915 I3104L Fan Blower Assembly 24 910 157 P Blower Fan Motor 25 910 678 Power Cord 120 Volts 27 910 142 Fan Thermodisc 28 910 140 Fan Speed Switch HI OFF LOW 3 way 29 910 138 Switch Auto Manual 2 way 30 Grommet Strain Relief 35 063 954 Air Tube 1 I3...

Страница 17: ...t of 3 385 Trim Right Regular 386 Trim Top Regular 387 Trim Left Regular 388 Faceplate Side Regular 389 Faceplate Top Regular 163 912 Faceplate Trim Set Oversize 163 572 Black Trim Oversize Set of 3 395 Trim Right Oversize 396 Trim Top Oversize 397 Trim Left Oversize 398 Faceplate Side Oversize 399 Faceplate Top Oversize Not available as a replacement part ...

Страница 18: ... 120 Volts 25 910 678 Power Cord 120 Volts 27 910 142 Fan Thermodisc 28 910 140 Fan Speed Switch HI OFF LOW 3 way 29 910 138 Switch Auto Manual 2 way 30 Grommet Strain Relief 35 120 954 Air Tube Front 36 120 953 Air Tube Rear 37 836 212 Baffle Insulation 38 Insulation Weights 39 120 950 Steel Baffle 948 216 Regency Logo Faceplate H2104M 120 910 Faceplate Trim Set Regular 120 570 Black Trim Regular...

Страница 19: ...11 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 71 Brick Partial 1 1 4 x 4 x 9 72 Brick Partial 1 1 4 x 1 3 4 x 9 75 Brick Partial 1 1 4 x 4 x 8 3 4 76 Brick Partial 1 1 4 x 2 x 9 78 Brick Partial 1 1 4 x 2 1 4 x 2 1 4 81 Brick Partial 1 1 4 x 1 1 4 x 9 84 Brick Partial 1 1 4 x 4 1 2 x 8 85 Brick Partial 1 1 4 x 4 1 4 x 8 Not available as a replacement part ...

Страница 20: ...wiring switches etc 2 Glass Crazing 1 Catalyst Assembly 6 Years Prorated 3 Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defective during the warranty period as outlined above will be repaired or replaced at FPI s option through an accredited distributor dealer...

Страница 21: ...d mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solvents cardboard coal or coal products oil based products waxed cartons compressed pre manufactured logs lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result ...

Страница 22: ... should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief des...

Страница 23: ...rder for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made i...

Страница 24: ......

Страница 25: ...H2104 I3104 Wood Insert 25 25 notes ...

Страница 26: ...26 H2104 I3104 Wood Insert 26 notes ...

Страница 27: ......

Страница 28: ..._______________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Printed in Canada Regency and Classic are trademarks of FPI Fireplace Products International Ltd Copyright 2016 FPI Fireplace Products International Ltd...