Regency GF900C-2 Gas Fireplace
23
installation
Flue restriction is required for certain flueing installations, see the diagrams in the "Flueing
Arrangements" section to determine if they are required for your installation.
The Flue Restrictor plate is located on the inside top of the firebox.
To set the flue restriction as indicated in the flueing arrangements diagrams, refer to the following instructions;
1. Remove the glass door and inner panels - see instructions in this manual.
2. Remove 6 screws (3 front - 3 back) to remove heat baffle to access restrictor plate.
FLUE RESTRICTOR POSITION
Set 0 - 64mm Open
Set 2 - 18mm open
Set 1 - 26mm open
Set 3 - 15mm open
Heat Baffle
3. Remove the screws that hold the flue restrictor in place.
4. Adjust the flue restrictor plate to the required flue restrictor position as per the diagrams shown below.
5. Once the flue restrictor plate is in the required position, secure with screws.