background image

WARNING:  
If the information in these instructions are not followed exactly, 
a fire or explosion may result causing property damage, 
personal injury or loss of life. 

FOR YOUR  SAFETY
Do not store or use gasoline or other flammable vapors and 
liquids in the vicinity of this or any other appliance.

Installation and service must be performed by a qualified 
installer, service agency or the gas supplier.

 FOR YOUR SAFETY
 What to do if you smell gas:

 

Do not try to light any appliance

 

Do not touch any electrical switch: 
do not use any phone in your 
building.

 

Immediately call your gas supplier 
from a neighbour's phone. Follow 
the gas supplier's instructions.

 

If you cannot reach your gas 
supplier, call the fire department.

920-038

Greenfire

®

 GF900C 

Gas Fireplace

14 March 2019

Owners & 

Installation Manual

www.regency-fire.com.au

Installer

: Please complete the details on the back cover and leave this manual with the homeowner.

Homeowner:

 Please keep these instructions for future reference.

MODELS:   GF900C-NG2 
                   GF900C-LP2
                   GF900C-ULPG2

LISTINGS AND CODE APPROVALS

These gas appliances have been tested in 
accordance with  AS/NZS 5263.0, AS/NZS 
5263.1.3 and have been certified by the 
Australian Gas Association for installation 
and  operation  as  described  in  these 
Installation and Operating Instructions.
Must be installed as per AS/NZS5601
Your unit should be serviced annually 
by an authorised service person.

GF900C Video

Содержание Greenfire GF900C

Страница 1: ...one Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department 920 038 Greenfire GF900C Gas Fireplace 14 March 2019 Owners Installation Manual www regency fire com au Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference MODELS GF900C NG2 GF900C LP2 GF...

Страница 2: ...des helps to differentiate one Remote Control Handset from another so that only the control box with a matching ID code will respond to the appropriate Remote Control Handset To match the control box the following steps are to be followed 1 Ensure the Remote is switched OFF 2 Remove main power to the control box 3 Reconnect main power to the control box 4 Press and hold the PROG and FAN buttons si...

Страница 3: ...ations 24 Flueing Arrangements 25 Horizontal Termination Flex 25 Rigid Pipe 4 x 6 5 8 102mm x 175mm 26 Vertical Terminations Rigid Pipe 28 Flueing Arrangement for Vertical Terminations 29 Direct Flue Zero Clearance Top Exit Vertical Flue Kit Installation Instructions GF900 30 Unit Installation with Horizontal Termination 31 Unit Installation with Vertical Termination 33 System Data 34 High Elevati...

Страница 4: ...ern Australia Air Group Australia 28 Division St Welshpool WA 6106 Eastern Australia Fireplace Products Australia Pty Ltd 1 Conquest Way Hallam VIC 3803 New Zealand Aber Holdings 17 Main Street Place Te Rapa HA 3200 To be installed by an authorised person in accordance with installation instructions provided with the appliance Electrical 240V 50 Hz 0 8A 920 022 Gas Type NG Propane ULPG Model GF900...

Страница 5: ...C 2 Gas Fireplace 5 DIMENSIONS dimensions UNIT DIMENSIONS 1192mm 641mm 989mm 438mm Verona Surround Faceplate Dimensions 996mm 1091mm 113mm 540mm 890mm 332mm 159mm 726mm 796mm 933mm 14mm 523mm 560mm 258mm 500mm 74mm ...

Страница 6: ...anyone who is unfamiliar with the operation to use the fireplace 9 Wearglovesandsafetyglassesforprotection while doing required maintenance 10 Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination THIS UNIT MUST ALWAYS TERMINATE FLUE DIRECTLY TO THE OUTDOORS IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The GF900C Direct Flue Fireplace must be installed in ac...

Страница 7: ...lly explained to customer INSTALLATION CHECKLIST 1 Locate appliance a Room location Refer to Locating Your Gas fireplace section b Clearances to Combustibles Refer to Clearances section c Mantle Clearances Refer to Mantel Clearances section d Framing Finishing Requirements Refer to Framing Finishing section e FlueingRequirements Referto Flueing section 2 Assemble the standoffs and nailing strips R...

Страница 8: ...ce Opening Hot Air Outlet B Sidewall on one side 146mm Side of Fireplace Opening C Ceiling room and or alcove 1003mm Top of Fireplace Opening D Mantel Depth max 305mm 420mm Above Fireplace Opening E Alcove Width 1480mm Sidewall to Sidewall Minimum F Alcove Depth 787mm Front to Back Wall Maximum G From Floor 605mm Top of Fireplace Opening Hot Air Outlet Note 0 No hearth required Installed close to ...

Страница 9: ...dwhenchoosingthecombustibleflushfinishingoption Note must maintain 13mm air gap all around the perimeter of the appliance when choosing this option D G H Non Combustible Facing Header F E I J K L Flex or Rigid Pipe Drywall or other facing C C A B C Timber Studs Finished Floor A B C Timber Studs Finished Floor Non combustible Flush Finishing Framing A 1 Steel Stud on edge NOTE Donotplacetimber stud...

Страница 10: ...le The nailing strips can be adjusted back up to 38mm to allow for varying thicknesses in non combustible material wall finishes INSTALLATION ACCESS PANEL The unit is equipped with a removable access panel for pre finish installation of optional components this panel is located on the lower front face 1 Remove 4 screws to remove access panel 2 Easier access to gas connection with panel removed 3 I...

Страница 11: ...ailing strip is fixed during transit to the rear of the appliance Do not place any reinforcement in front of header and behind finishing material The nailing strip must be used It is fixed during transit to the rear of the unit NOTE The appliance must be installed on a flat solid continuous surface For example a wood metal or concrete floor In a raised on the wall application the appliance must be...

Страница 12: ...d the facing is high quality or the paint may discolour Note Combustible mantel starts at 796mm 618mm 178mm from unit base COMBUSTIBLE MANTEL LEG CLEARANCES Mantel leg combustible finishing clearances as per diagram Combustible Material 152mm 305mm 0mm 618mm To unit base 254mm Top of Fireplace Opening 508mm 305mm 407mm 178mm Combustible Stud On Edge Nailing Flange Combustible facing min 10mm max 1...

Страница 13: ...ss panel removed 4 Reinstall access panel line up 2 upper tabs and secure in place with 4 screws Note Access panel is no longer usable accessible once facing material installed Installation Access Panel Tab locations on access panel Remove 7 standoffs REMOVE TOP NAILING STRIPS STANDOFFS Remove the top nailing strip standoff by removing 4 screws in locations shown in Diagram to the right then lift o...

Страница 14: ...the mantel and the facing is high quality or the paint may discolour Note Combustible mantel starts at 796mm 605mm 191mm from unit base NON COMBUSTIBLE MANTEL LEG CLEARANCES Mantel leg Non combustible finishing clearances as per diagram Flushed Finish Allowablemantel leg projection 181mm 254mm 330mm 38mm MANTELLEG 102mm 178mm Allowablemantel leg projection 181mm 254mm 330mm 38mm MANTELLEG 102mm 17...

Страница 15: ...d sides must also be used NOTE Theappliancemustbeinstalledon aflat solid continuoussurfaceFor exampleawood metalorconcrete floor In a raised on the wall ap plication the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance 796mm 605mm 1165mm Non combustible Combustible Combustible Steel Stud on edge Timber Stud Timber Stud 159mm 446mm Non Combust...

Страница 16: ...red without any sag Heat deflector must overhang front of TV by 51mm Follow mantel clearance chart for install height and heat deflector depth Note The TV mounting bracket can not be secured directly to the appliance It must be secured to framing The TV depicted in the picture may need to be higher depending on the style of TV mounting bracket used The mounting bracket shown is a simple single str...

Страница 17: ...eplace 17 installation M 5 3 4 146mm 14 9 16 370mm DETAIL M SCALE 1 6 INSTALLING A TV ARTWORK ENCLOSED ABOVE THE UNIT Maximum recess is 146mm Minimum height is 370mm from top lip Ensure framing does not interfere with venting ...

Страница 18: ...t bottom 2 at top and 2 on sides as shown NOTE Ensure the flat side of the steel stud is facing the timber framing 468 025 Flat side out 5 Secure horizontal steel header stud 468 039 with 2 screws per side as per diagram 6 Slide the unit into position Hook up gas flueing electrical and conversion kit if purchased prior to installing the remaining steel studs 7 Secure the upper horizontal steel stu...

Страница 19: ...ed with non combustible required materials to specific dimensions above and aroundtheunits Thisisduetotheseareasreachinghighertemperature levels than required acceptable for a combustible material To obtain the best most durable finish around your fireplace this calls for a high level of care and attention to the preparation and finish around this appliance using only the highest quality materials...

Страница 20: ...cessive condensation on glass doors poor flame package carbon blue flames etc These are not product related issues 3 The unit does not have to be completely enclosed in a chase You must maintain clearances from the flue to combustible materials See Clearances section Combustible materials can be laid against the side and back standoffs and the appliance base 4 Non combustible material ie tile slat...

Страница 21: ...Regency GF900C 2 Gas Fireplace 21 installation EXTERIOR FLUE TERMINATION LOCATIONS FIGURE 6 2 in part LOCATION OF FLUE TERMINALS OF BALANCED FLUE AS NZ 5601 ROOM SEALED FAN ASSISTED OR OUTDOOR APPLIANCE ...

Страница 22: ...liances over 250MJ h input 1500 1500 All fan assisted flue appliances in the direction of discharge 1500 k From a mechanical air inlet including a spa blower 1500 1000 n Vertically below an openable window non mechanical air inlet or any other opening into a building iwth the exception of sub floor ventilation Space heaters up to 50MJ h input 150 150 Other appliances up to 50 MJ h input 500 500 Ap...

Страница 23: ...ments diagrams refer to the following instructions 1 Remove the glass door and inner panels see instructions in this manual 2 Remove 6 screws 3 front 3 back to remove heat baffle to access restrictor plate FLUE RESTRICTOR POSITION Set 0 64mm Open Set 2 18mm open Set 1 26mm open Set 3 15mm open Heat Baffle 3 Remove the screws that hold the flue restrictor in place 4 Adjust the flue restrictor plate...

Страница 24: ... elbow Note Must use optional rigid pipe adapter Part 510 994 when using Rigid Pipe Flueing Systems Maintain clearances to combustibles as listed in Clearances section Horizontal flue must be supported every 0 9m Firestops are required at each floor level and whenever passing through a wall A flue guard should be used whenever the termination is lower than the specified minimum or as per local cod...

Страница 25: ...mm flexible outer liner Kit length 2 102mm flexible inner liner Kit length 3 spring spacers 4 thimble 5 AstroCap termination cap 6 screws 7 tube of Mill Pac 8 plated screws 9 S S screws 8 x 1 1 2 drill point 946 516 3 m FLUEING ARRANGEMENTS HORIZONTAL TERMINATION FLEX Regency Direct Vent System These flueing systems in combination with GF900C have been tested and listed as a Direct Vent system by ...

Страница 26: ...nd add 51mm When using Rigid Flue other than Simpson Dura Vent 3 screws must be used to secure rigid pipe to adaptor WARNING Do not combine flueing components from different flueing systems However use of the the AstroCapTM and FPI Riser is acceptable with all systems ThisproducthasbeenevaluatedbyIntertek forusingaRigidPipeAdaptorinconjunction with Duravent Direct Vent The FPI AstroCapTM and Regen...

Страница 27: ... or two 45o elbows is permitted 2 Minimum distance between elbows is 305mm Maintain clearances to combustibles as listed in the Clearances section Horizontal vent must be supported every 0 9m Must use optional rigid pipe adaptor Part 510 994 when using Duravent systems A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes Flex system can onl...

Страница 28: ...allations using FPI flueing systems as well as Simpson Dura Vent Direct Vent is a proprietary trademark of FPI Fireplace Products International Ltd Dura Vent and Direct Vent are registered and or proprietary trademarks of Simpson Dura Vent Co Inc Galvanized pipe is desirable above the roofline due to its higher corrosion resistance Continue to add pipe sections through the flashinguntiltheheightof...

Страница 29: ...ombustibles as listed in the Clearances section Horizontal flue must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall Must use optional rigid pipe adaptor Part 510 994 when using rigid pipe flue systems Refertothe FlueRestrictorPosition sectionfordetails on how to change the flue restrictor from the factory setting of Set 0 to Set 1 or Set 2 ...

Страница 30: ...sing non combustible brac ing to stop movement On penetration of roof fit an appropriate flashing or weather seal to suit the roofing material ensure all joints outside are sealed with appropriate sealer 6 Fit gas cowl 46DVA VCH 9 or flomet cap 946 651 ensuring inner and outer flue pipes are sealed 7 Start heater and run for at least 15 minutes to check flue seal If operational issues are noted ch...

Страница 31: ...ner and outer flue collar Fasten to the outer collar only with the 3 supplied screws drilling pilot holes will make this easier 4 Level the fireplace and fasten it to the framing using nails or screws through the top and side nailing strips Note For best results and optimum performance with each approved venting system it is highly recommended to apply Mill Pac sealant to every inner pipe connecti...

Страница 32: ...he cap indicating which way is up This will position the termination cap with proper down slope for draining water Fasten the cap to the outer wall with the 4 supplied screws 6 Pull the centre inner and outer flex liner out enough to slip over the flue collars of the fireplace You may wish to cut the liner shorter to make it more workable Do not bend liner more than 90o The liners must slip over t...

Страница 33: ...he elbows and possible separation Metal Wall straps can be used Do not combineflueingcomponentsfromother manufacturers Galvanizedpipeisdesirableabovetheroofspace due to its higher corrosion resistance Continue to add pipe sections through the flashing until the height of the flue cap meets the minimum height requirements specified in Dia 4 or local codes Note that for steep roof pitches the vertic...

Страница 34: ...cy dealerforfurther instructions Incorrectflamepatternwillhavesmall probably yellow flames not coming into proper contact with the rear burner or flame sensor Burner Flame Sensor Pilot Ignitor PILOT ADJUSTMENT Periodicallycheckthepilotflames Correctflame pattern has two strong blue flames 1 flowing around the flame sensor and 1 flowing across the burner it does not have to be touching the burner 8...

Страница 35: ...N 4 5 3 2 1 YELLOW 3 YELLOW BLUE GND BROWN LOW SPEED WHITE RED BLACK FAN 5 3 4 BROWN VIOLET BLUE RED 1 3 2 4 WHITE YELLOW VIOLET BLACK 5 6 1 2 BROWN BLUE VIOLET RED BLACK WHITE YELLOW VIOLET ORANGE ORANGE MODULATING 7 8 6 5 4 3 VALVE RESET SWITCH NC BLACK BLACK 2 1 COIL MODULE SPARK MODULE GROUND MODULE FLAME ORANGE ORANGE 5 4 ORANGE ORANGE GREEN SPARKER RED THERM COMMAND BOX FAN LOW ACTIVE NEUTRA...

Страница 36: ...t GF900C Kit 466 967 Qty Part Description 1 904 345 Burner Orifice 53 1 918 590 Decal Converted to LP 1 919 728 Orange Propane Label 1 918 272 Conversion to ULPG decal 1 904 529 5 32 Allen Key 1 910 037 Propane Injector 1 911 137 Pilot hood holding clip 1 919 727 Red ULPG label 1 920 039 Instruction Sheet IT WOULD BE BENEFICIAL TO CONVERT THE APPLIANCE PRIOR TO THE UNIT BEING INSTALLED OR WALL FAC...

Страница 37: ...ol box is held in place with velcro 11 Remove the heat shield from the control box by removing the 2 screws 12 Remove the control box cover by undoing the 3 screws Manoeuvre through antenna 14 Reverse steps 12 11 15 Adjust the air shutter opening See page 37 for Aeration Adjust ment Reverse steps 4 2 and 1 16 Turn on gas supply and plug in power cord Cable Electric Modulator Control Box Cover Ante...

Страница 38: ...fire hazard 6 Plan the location of the fireplace and the warm air duct runs see diagram 1 as a guide for possible duct runs and locations Diagram 1 Guide for possible air duct runs and locations Keep duct length and number of bends to a minimum Maximum duct length is 9 0m The Extension Kit contains a maximum of up to 4 5m Please purchase the Fan Duct Extension Kit to increase the 9 0m MINIMUM FRAM...

Страница 39: ...an Housing See diagram 4 8 Remove the knock out on the top of the unit Cut out the insulation Remove the second and thirdknockout botharebelowthetopknockout 9 On the top of the unit bend the 3 tabs up Insert the Duct collar Secure the collar to the 3 tabs with screws 10 Attach fan duct to the unit Slide the ducting over the collar and secure with screws 11 Final step double check the fan ducting c...

Страница 40: ...AM Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges AlternateSwitches Mayusethefollowing Checkwithlocalauthoritiesandelectrician CLIPSAL 203 2E45 OUD Dimmer CLIPSAL 2031 VF3CSF 3 Speed CAUTION Labelallwirespriortodis connection when servicing controls Wiringerrorscancauseimproperand dangerous operation Wire Nut Wire Nut Wire Nut Rheostat Wire Nuts Wire Wire...

Страница 41: ...s or stones are spread evenly over the burner 1 PLACEMENT OF GLASS CRYSTALS 1 Start installing Crystals on the Burner NG Propane ULPG 2 Distribute Crystals evenly starting from back of Firebox Floor 3 Work Crystals from back to front edge of Firebox Floor 4 Ensure Crystals DO NOT block the front of the pilot hood and flame to light the burner 2 PLACEMENT OF VOLCANIC STONES AROUND BURNER NG UNIT NO...

Страница 42: ...EMOVAL INSTALLATION 3 Remove two 2 screws in locations shown below to release panel clips 4 Remove 3 screws in locations shown below to remove burner tray 919 615 11 05 15 1 OPTIONAL FINISHING TRIM INSTALLATION tooltip tooltip 1 Install the optional finishing trim by lining up trim with the outside of the fascia Press trim inward firmly to seat onto the unit Note magnets will keep the trim in plac...

Страница 43: ...st to the door frame overlay out of the 3 so that the faceplate and door frame overlay are flush with one another See diagram 2 1 Install the fascia to the unit by hooking the left and right side mounting brackets into the mounting slots at the side ofthe firebox as shown below Diagram 3 Diagram 4 Deflector Installed NOTE When installing the stainless steel fascia gloves should be worn to prevent ...

Страница 44: ...wn in Diagram 1 3 Install Screen and Inner Door Frame to unit but hanging over glass door frame as shown in Diagram 3 Lower gently once in position over glass door frame 2 Bend Tab on Screen Mesh to 90º as shown in Diagram 2 Secure to Inner Door Frame with one 1 screw as shown in Diagram 2a Diagram 1 Diagram 3 Diagram 2 Diagram 2a ...

Страница 45: ...releasing this button once will switch the unit off Flame Increase If the unit is switched on pressing and releasing the flame plus button once will increase the flame height to the next available high setting Decrease If the unit is switched on pressing and releasing the flame minus button once will decrease the flame height to the next avail able low setting Fan Increase If the unit is switched ...

Страница 46: ...E ONLY FOR INDOOR INSTALLATION A BEFORE LIGHTING smell all around the appliance areaforgas Besuretosmellnexttothefloorbecause some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbors phone Follow the gas supplier s...

Страница 47: ... shown below 8 Loosen three 3 screws to remove heat deflector shown in Diagram 5 9 Remove two 2 screws to remove fan shown in Diagram 6 10 Reverse steps to reinstall fan 7 Remove valve tray by removing fourteen 14 screws in locations shown in Diagram 4 Diagram 5 Valve Tray Screws Diagram 4 Heat Deflector Screws Diagram 6 Fan Screws Diagram 2 Burner Screw Locations Diagram 3 Air Deflector Screw Loc...

Страница 48: ... Check the Flueing System for corrosion in areas that are exposed to the elements These will appear as rust spots or streaks and in extreme cases holes These components should be replaced immediately 2 Remove the Cap and shine a flashlight down the Flue Remove any bird nests or other foreign material 3 Check for evidences of excessive condensation suchaswaterdropletsforming in the inner liner and ...

Страница 49: ... after approx 1 minute Then turn on again NOTE On initial light up this may occur a number of times until any residual air is purged from the gas line through the burner system It is essential the required waiting time as stated in the manual is observed prior to attempting re ignition Turn burner switch to ON fans will operate within 5 secs listen for audible click first from After resetting ignit...

Страница 50: ... repeat steps 1 5 on the other lower door latch 6 Pull the bottom of the door towards you until the door is angled away from the firebox by about 30 Lift the door up and over the upper door hooks 7 To install the glass door reverse steps 1 Insert the door tool into the lower door latch WARNING Do not operate the appliance with the glass panels removed cracked or broken Replacement of the glass pan...

Страница 51: ...TO ROOM TEMPERATURE ALL POWER IS DISCONNECTED AND GAS SUPPLY IT TURNED OFF 1 Remove faceplate inner frame glass door and inner panels see instructions in this manual 2 Remove crystals and stones if installed 3 Remove burner tray by removing 3 screws shown in Diagram 1 4 Remove burner by removing 2 screws in locations shown below Diagram 2 Burner Screw Locations Diagram 3 Air Deflector Screw Locati...

Страница 52: ...A N A N A 910 089 Flame Cable N A N A N A N A N A N A N A N A 910 088 Spark Cable N A N A N A N A N A N A N A N A 910 084 Control Box N A N A N A 911 101 Control Box N A N A N A N A N A N A 910 527 Manual Control Switch N A N A N A N A N A N A 910 080 Valve 910 521 Control Box Cable 1 910 522 Control Box Cable 2 910 523 Control Box Cable 3 910 525 Control Box Cable 4 N A 2 1 1 3 N A 2 N A N A 910 ...

Страница 53: ...66 0 250 20 x 7in Hex Bolt 25 296 122 Door Spring 1 2 x 7 Stainless Steel 26 904 143 HEX NUT 1 4 20 27 476 062 Panel Clip 28 466 083 Heat Exchanger Gasket 29 466 088 Panel Bracket LH 30 466 089 Panel Bracket RH 31 466 548 GF900C Valve Tray 32 466 090 GF900C Glass Burner Tray 33 468 525 Glass Burner 34 466 092 Rear Tray 35 466 091 Pilot Hood 36 910 080 Sigma Valve NG LP 37 910 936 Pilot Assembly NG...

Страница 54: ...54 Regency GF900C 2 Gas Fireplace PARTS LIST parts list 5B 5A 38 36 37 17 MAIN ASSEMBLY ...

Страница 55: ... Inner door frame Stainless w Screen 33 467 544 Door Frame Overlay Black 34 468 934 Fascia and Door Frame Black w Screen 468 936 Fascia and Door Frame Stainless Steel w Screen 35 468 951 Fascia Black Glass w screen not shown 468 928 Finishing Trim 468 900 Steel Stud Kit 466 905 Weather Box 466 907 Inner Panel Brushed Stainless 32 33 34 ...

Страница 56: ...components Ignition Control Boards Wiring Switches Fans Fan Control Module Battery Pack Remote Control Systems 1 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Fire beads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 After the original warranty coverage for any of the parts abo...

Страница 57: ...general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect If a consumer has a unit installed outside an accredited distributor dealer or pre approved service agent s service area or the closest approved service agent is situated more than thirty 30 kilometres from the inst...

Страница 58: ...r movement expansion and contraction of the steel is normal and is not covered under the terms of this warranty Freight damages for products or parts are not covered under the terms of the warranty Porcelain Enamel Absolute perfection is neither guaranteed nor commercially possible Any chips must be reported and inspected by the authorised selling dealer within three 3 days of installation Any dam...

Страница 59: ...to at the option of the supplier one or more of the following i replacement of the goods or the supply of equivalent goods ii the repair of the goods iii the payment of the cost of replacing the goods or of acquiring equivalent goods or iv equivalent goods or v the payment of the cost of having the goods repaired b To the extent that services supplied by the supplier are services other than servic...

Страница 60: ...ervices Fireplace Products Australia Pty Ltd 1 3 Conquest Way Hallam VIC Australia 3803 Phone 61 3 9799 7277 Fax 61 3 9799 7822 To obtain warranty service in Western Australia and or New Zealand please contact one of our authorised distributors in those areas Western Australia Air Group Australia 28 30 Division St Welshpool WA Australia 6106 Phone 08 9350 2200 Fax 08 9353 4225 New Zealand Aber Hol...

Страница 61: ... in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases m...

Страница 62: ...62 Regency GF900C 2 Gas Fireplace ...

Страница 63: ......

Страница 64: ...ion Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No _________________________________________...

Отзывы: