Grandview
®
G800EH Gas Fireplace |
57
installation
Vertical Terminations - Vertical Venting With Two 90
o
Elbows
(Propane & Natural Gas)
Rigid Pipe System and Vertical Flex Kit to Same Limitations
Vertical Venting With Three 90
o
Elbows
(Propane & Natural Gas)
Rigid Pipe System and Vertical Flex Kit to Same Limitations
V1
V
H
V
H1
H
V1
One 90
o
elbow = Two 45
o
elbows.
Option
V
H
V + V1
With these options,
maximum total pipe length
is 30 feet with minimum
of 7 feet total vertical and
maximum 8 feet total
horizontal.
Please note mini
-
mum 1 foot between
90
o
elbows is re
-
quired.
A)
0' Min. 2' Max.
1' Min.
B)
1' Min. 4' Max.
3' Min.
C)
2' Min. 5' Max.
4' Min.
D)
3' Min. 6' Max.
5' Min.
E)
4' Min. 7' Max.
6' Min.
F)
5' Min. 8' Max.
7' Min.
Lengths do not include elbow indicated.
*Required when using rigid venting
One 90
o
elbow = Two 45
o
elbows.
Option
V
H + H1
V + V1
With these options,
maximum total pipe length
is 30 feet with minimum
of 10 feet total vertical
and maximum 8 feet total
horizontal.
Please note mini
-
mum 1 foot between
90
o
elbows is re
-
quired.
A)
0' Min. 2' Max.
2' Min.
B)
1' Min. 2' Max.
3' Min.
C)
2' Min. 3' Max.
4' Min.
D)
3' Min. 4' Max.
6' Min.
E)
4' Min. 5' Max.
7' Min.
F)
5' Min. 6' Max.
8' Min.
G)
6' Min. 7' Max.
9' Min.
H)
7' Min. 8' Max.
10' Min.
Lengths do not include elbow indicated.
*Required when using rigid venting
*
*