32
| Grandview
®
G800EH Gas Fireplace
installation
Chase Vent Installation—Cool Wall
Framed opening must be at least 3-5/8” (92mm) tall, and at least 33-3/8” (848mm) wide to accomodate the Chase vent. The top of the Chase vent opening
must be flush with the top of the chase enclosure. Fasten the Chase vent with screws and construction adhesive.
If the chase vent is not being used, a minimum 107in
2
(690cm
2
)
opening in the enclosure is required to maintain safe operating temperatures. This can be
achieved in a number of ways including a reveal at the top of the chase.
08.25.20
920-301
G600EC/G600C
1
08.11.20
920-150
G600EC
1
29
Ceiling
Max 2” (51 mm)
Ceiling
Max 2” (51 mm)
Side View
Top of enclosure
CHASE VENT INSTALLATION—COOL WALL
(PART #776-941)
Framed opening must be at least 2 3/8” (60 mm) tall, and at least 29 3/8” (746 mm) wide to accomodate the chase vent. The
top of the chase vent opening must be 2” (51 mm) or less from the top of the chase enclosure. Fasten the chase vent with
screws and construction adhesive.
If the chase vent is not being used, a minimum 58 in
2
(374 cm
2
) opening in the enclosure is required to maintain safe operating
temperatures. This can be achieved in a number of ways including a reveal at the top of the chase.
08.11.20
920-150
G600EC
1
29
Ceiling
Max 2” (51 mm)
Ceiling
Max 2” (51 mm)
Side View
Top of enclosure
(746 mm)
(60 mm)
Min. 33-3/8''
(848 mm)
3-5/8''
(92 mm)
Room ceiling
Enclosure ceiling
3 1/4” H x 33“ W
opening
Enclosure ceiling must be flush
with ventilation opening
Fireplace Chase
Enclosure
Stud
Stud
Regency
Chase Vent
Screw Holes
(Screws into
upright side
studs)
IMPORTANT: