    Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

 

    WHAT TO DO IF YOU SMELL GAS

 • 

Do not try to light any appliance.

  •  Do not touch any electrical switch: do not use any phone in your building.

    Leave the building immediately.

  •  Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.

  • If you cannot reach your gas supplier, call the fire department.

   

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

920-614

    FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  

6988 Venture St., Delta, BC  Canada, V4G 1H4

11.08.22

Installer: 

 

Please complete the details on the back cover and 

leave this manual with the homeowner.

Homeowner

:

 

Please keep these instructions for future reference.

Certified to/Certifié pour: CSA 2.17-2017

                                    CSA/ANSI Z21.88-2019

                                    CSA 2.33-2019

Tested by: 

     Warning

Fire or Explosion Hazard

Failure to follow safety warnings exactly could result in serious

injury, death, or property damage.

 

Содержание Grandview G800EH

Страница 1: ...the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier 920 614 FPI FIREPLACE PRODUCTS INTERNATIONAL LTD 6988 Venture St Delta BC Canada V4G 1H4 11 08 22 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeown...

Страница 2: ...t Label 4 34 6 Instruction Plate Each appliance shall bear a Class IIIB marking with letters on a contrasting background located adjacent to the controlling device or in an equally conspicuous position where the instruction can be easily read April 22 14 Created draft Double sided Material Synthetic Paper Size 5 965 W x 5 71 H Color As shown in artwork DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUC...

Страница 3: ...ational Electrical Code ANSI NFPA 70 in the U S A and the current CSA B149 1 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This appliance comes equipped with a dedicated 8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local codes The appliance when installed must be electrically grounded in accordance with local codes or in ...

Страница 4: ... other spaces of the building 4 Close fireplace dampers 5 Turn on clothes dryers and any appliance not connected to the venting system Turn on any exhaust fans such as range hoods and bathroom exhausts so they are operating at maximum speed Do not operate a summer exhaust fan 6 Follow the lighting instructions Place the appliance being inspected into operation Adjust the thermostat so appliance is ...

Страница 5: ... Direct Vent System Flex 52 Rigid Pipe Venting Systems Horizontal or Vertical Terminations 53 Venting Arrangements Horizontal Termination Rigid Pipe and Direct Vent System Flex 54 Venting Arrangements Vertical Termination Rigid Pipe System and Vertical Flex Kit to Same Limitations 55 Horizontal Terminations Two 90 Elbows 56 Horizontal Terminations Three 90o Elbows 56 Vertical Terminations Vertical...

Страница 6: ...ssure high Manifold pressure low Orifice size Minimum input Maximum input Altitude This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 or Natural Gas and Propane Installation Code CSA B149 1 This appliance must be installed in accordance with the Standard CAN CSAZ240 MH Mobile Housing in Canada or with the Manufactured Home C...

Страница 7: ...e with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the ins...

Страница 8: ...mm 1 5 8 41mm 1 5 8 42mm 33 7 8 861mm 35 1 8 891mm 7 1 2 191mm 36 3 8 925mm 11 1 4 287mm 1 1 2 37mm 11 1 4 287mm ELECTRICAL INLET 4 101mm 6 5 8 169mm 21 3 4 554mm 18 456mm 32 3 8 822mm FIREPLACE OPENING 7 5 8 195mm 1 1 4 32mm GAS INLET 37 3 4 959mm 34 3 4 883mm 37 1 2 953mm 34 5 8 880mm Finishing Trim Faceplate Note Gas connection is from the left hand side of the appliance electrical connection o...

Страница 9: ...converted to top or rear vent per manual instructions and the insulation discarded Venting YES NO Are the venting components approved for the unit installed Does the venting configuration comply with venting diagrams Is venting installed and secured and are clearances for the vent pipe and termination cap maintained If applicable was a 1 4 rise maintained for every foot of horizontal run Was the t...

Страница 10: ... air shutter on the proper setting after running the unit for 20 minutes If applicable were the surround and trims installed according to the manual Was the operation of the fan lights if installed and flame modulation checked Customer Tutorial and Presentation YES NO Is the customer confident operating the new gas appliance and aware of all the features on the remote Confirm that the rating and l...

Страница 11: ...AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURETOINSTALLTHIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE YOUNG CHILDREN SHOULD BE CARE FULLY SUPERVISED WHEN THEY ARE IN THE SAME AREA AS THE APPLI ANCE TODDLERS YOUNGCHILDREN AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENTAL CONTACT BURN...

Страница 12: ...oFlame 2 system fitted with the On Demand Pilot a safety feature which will shut down the gas valve completely by extinguishing the pilot light in the event of a continuous full seven days of inactivity This only applies if the CPI continuous pilot switch is in the on position in your remote control transmitter Each time the main burner shuts down manually or through the call from the thermostat t...

Страница 13: ...iatement le bâtiment Appelez immédiatement votre fournisseur de gaz depuis un téléphone extérieur Suivez les instructions du fournisseur Si vous ne pouvez pas rejoindre le fournisseur appelez le service incendie C N utilisez pas cet appareil s il a été plongé dans l eau même partiellement Faites inspecter l appareil par un technicien qualifié et remplacez tout élément du système de contrôle ou de ...

Страница 14: ...tanding or intermittent pilot CPI IPI 4 Thermostat and Smart thermostat functions 5 Accent light modulation 6 levels 6 Split flow valve 7 Comfort Fan speed modulation 6 levels This feature is not available on any Hampton models IMPORTANT The Proflame Transmitter 2 is an integrated part of the Proflame 2 System which consists of these elements Proflame 2 Transmitter to be used in conjunction with I...

Страница 15: ...ep until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position Fig 7 8 A single beep will confirm reception of the command Fig 7 Fig 8 Room Thermostat Transmitter Operation The Remote Control can operate as a room thermostat The thermostat...

Страница 16: ...n speed can be adjusted through six 6 speeds To activate this function use the Mode Key fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adjust the fan speed fig 14 A single beep will confirm reception of the command Figure 13 Figure 14 Remote dimmer control Light The auxiliary function controls the AUX power outlet by the dimmable light control To a...

Страница 17: ...anged from an inter mittent pilot ignition system IPI to a continuous pilot ignition system CPI by using remote control as noted above The benefits of having as CPI are as follows Keeps venting primed for trouble free start up under colder weather conditions or inversions Keeps the unit glass warm which decreases the amount of condensa tion on start up Provides owners with flexibility to choose a ...

Страница 18: ...3 STEP 4 Reinstall wall cover plate with 2 Phillips head screws Replace 4 x AA batteries and insert the battery compartment back into remote receiver battery holder Move both the left right slides as shown below The battery compartment will be pushed out slightly to allow to easily extract it Extract the battery compartment from the remote receiver battery holder Close the right slide Keeping the ...

Страница 19: ...stallation Glass Door Removal 1 To install the door Reverse steps above 1 To remove the glass door place both hands on either side of the latch Pull forward then up to unlock repeat on opposite side Important After releasing the latches support the weight of the door 2 With both latches released support the door with both hands and tilt out to approximately a 60 degree angle 3 Lift the door up and...

Страница 20: ... the installation It is the responsibility of the installer to ensure this fireplace is installed in compliance with manufacturer s instructions and all applicable codes General Safety Information 1 The appliance installation must conform with local codes or in the absence of local codes withthecurrentCanadianorNationalGasCodes CSA B149 1 or ANSI Z223 1 Installation Codes 2 Theappliancewheninstall...

Страница 21: ...ent Refer to Venting sections 4 Make gas connections Test the pilot Must be as per Diagram Refer to Pilot Adjustment section Convert to propane if desired Refer to Gas Line Installation and Conversion Kit from NG to LPG sections 5 Make electrical connections to receptacle supplied with unit recommended 6 Install standard and optional features Refer to the following sections a Standard Glass Door b...

Страница 22: ...ombustible Installation Cool Wall Installation Cool Wall Conversion Cool Wall Clearances Cool Wall Mantel Clearances Cool Wall Mantel Leg Clearances Outside Finish Installation Non Cool Wall Framing Chase Venting Chase Vent Installation Cool Wall Clean Front Installation Non Cooll Wall Clearances Clean Front Installation Non Cooll Wall Mantel Clearances Clean Front Installation Non Cool Wall Mante...

Страница 23: ...bustible Installation Clean Front Install Non vented chase Non combustible board required Combustible framing Cool Wall Install Vented chase Combustible material can be used all around the fireplace Combustible framing Clean Front Clean Front Outside Finish w Finishing Trim Outside Finish w Faceplate ...

Страница 24: ... the framing has been built the nailing Flanges will need to be set depending on the depth of finish ing material being used Up to 1 1 4 total material thickness can be used including the backing mate rial The depth of finishing material can be adjusted in 1 4 increments 1 Determine the required depth setting for the materials being used 2 Once the setting has been chosen install the Left and Righ...

Страница 25: ...Finishing Material Backing Material Drywall etc Flush Finishing Material CLEAN FRONT Top Nailing Flange Standoff Deflector 5 Slot the Standoff Deflector onto the back screws then secure the with a screw through the remaining front hole on each flange 3 Screw one screw into the rear hole on each Side Nailing Flange 4 Install the Top Nailing Flange with 4 screws Nailing Flange Installation 1 1 4 Max...

Страница 26: ...op of Fireplace Opening B Sidewall 6 152mm Side of Fireplace Opening C Ceiling 51 1 2 1308mm Top of Fireplace Opening D Mantel Depth max 18 457mm Front of Fireplace Opening E Alcove Width 84 2134mm Wall to Wall Minimum F Alcove Depth 36 914mm Front to Back Wall Maximum G Convection Air Outlet 107 sq 690cm2 Top Front of Enclosure H Convection Air Outlet Opening Ceiling Offset Min 2 Top of Chase Ven...

Страница 27: ... From Top of Fireplace Opening 32 1 2 826 mm 12 305 mm 7 1 2 191 mm 4 102 mm Mantel Clearances 0 12 0 Top of Fireplace Opening A B To Floor 12 24 Inches C D Non Combustible Material Min 4 H 102mm 18 7 12 24 Combustible Mantel leg Allowable mantel leg projection TopView Side opening of fireplace Mantel leg Mantel leg 2 51mm 3 76mm 1 3 4 44mm 32 3 4 832mm overall fireplace width Clean finish 6 152 mm 5...

Страница 28: ...height Dimension N N the thickness of the installed hearth Q P R M N O S S U T V Combustible header Top Vent Rear Vent W Corner Top Vent Only IMPORTANT Corner applications are vented from the top only rear venting cannot be used Note The 2 standoffs at the rear of the appliance may be removed as these are not required in this application Ensure that any screws that are removed are reinstalled The ...

Страница 29: ...it and discard 3 Slide out tab as shown to remove recycle part 4 Insert a large slotted screwdriver into the slot in between front and back tabs bend the three 3 tabs up 90 towards the front DO NOT REMOVE TABS 5 Bend the rear three 3 tabs up 90 towards the back of the unit 6 Flip top panel 180 and reinstall to top of unit with four 4 screws in loca tions shown below ...

Страница 30: ...Minimum height of enclosure from base of appliance is 82 2083mm A minimum 107in2 opening in the enclosure is required to maintain safe operating termperatures This can be achieved in a number of ways including the examples shown below Warning DO NOT cover or place objects in front of the air outlet s Regency Chase Vent Custom Chase Vent Reveal at Ceiling ...

Страница 31: ...e is extended to the ceiling the ceiling will also need to be finished in a manner to prevent heat escaping into floor joist attic space One of the following methods must be used to prevent the heat from escaping a If choosing drywall ensure that the drywall is butt up tight with no gaps b Plywood wood studs etc installed tightly with no gaps As this appliance has been designed with all hot air es...

Страница 32: ...PART 776 941 Framed opening must be at least 2 3 8 60 mm tall and at least 29 3 8 746 mm wide to accomodate the chase vent The top of the chase vent opening must be 2 51 mm or less from the top of the chase enclosure Fasten the chase vent with screws and construction adhesive If the chase vent is not being used a minimum 58 in2 374 cm2 opening in the enclosure is required to maintain safe operatin...

Страница 33: ...es air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions Minimum Vent Clearances to Combustibles G800EH Clearance Requirements Clearance Dimension Measured From A Mantel Height min 20 508mm Top of Fireplace Opening B Sidewall 25 635mm Side of Fireplace Opening C Ceiling 36 1 2 927mm Top of Fir...

Страница 34: ... the right Note Ensure the paint that is used on the mantel and the facing is High Quality or the paint may discolour Mantel Clearances G800EH A B C D From Top of Fireplace Opening 32 1 2 826mm 28 711mm 23 1 2 597mm 20 508mm Combustible Mantel Clearances 0 12 0 Top of Fireplace Opening A B To Floor 12 24 Inches C D Non Combustible Material Min 20 H 508mm 12 1 6 Optional Non Combustible Header The ...

Страница 35: ...SHING MATERIAL IN THIS AREA No Combustible Materials in this Area 37 1 2 953mm 11 1 2 292 mm 3 76mm 3 76mm 30 7 8 784 mm 1 5 8 41 mm See framing dimensions on next page Allowable mantel leg projection TopView Side opening of fireplace Mantel Mantel leg 38mm 4 1 4 108mm Leg 3 76mm 6 7 8 175mm 32 1 2 826mm Overall Fireplace width 1 1 2 2 38mm 51mm 32 3 4 832mm Overall Fireplace Width Clean Finish 5 2...

Страница 36: ...idth 3 76mm W Clearance to corner of unit 2 3 4 70mm Non combustible Height 11 1 2 292mm Important Framing height requires consideration of the hearth height Dimension N N the thickness of the installed hearth S S U T V Q P M N O Combustible header R Top Vent Rear Vent W Corner Top Vent Only IMPORTANT Corner applications are vented from the top only rear venting cannot be used S1 The framing depth...

Страница 37: ... Flange Instructions Optional Clean Front Trim Optional Clean Front Trim Install Instructions Part 761 929 1 Loosen the four 4 screws that at tach the right and left nailing flanges to the unit 2 Slide the left and right tiling flanges onto the front of the fireplace Use the slots to center with the screw securing the Nailing Flanges 3 Tighten screws down 4 Slide the Bottom Tiling Flange against t...

Страница 38: ... is failure to maintain required clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions Minimum Vent Clearances to Combustibles G800EH Outside Finish Clearance Requirements Clearance Dimension Measured From A Mantel Height min 20 508mm Top of Fireplace Opening B Sidewall 25 635mm one...

Страница 39: ...learances from top of front facing are shown in the Diagram below Mantel Clearances G800EH A B C D From Top of Fireplace 34 864mm 26 5 673mm 22 559mm 18 5 470mm Outside Finish Installation Non Cool Wall Mantel Leg Clearances Allowable mantel leg projection TopView Side opening of fireplace Mantel Leg 1 1 2 38 mm 4 1 4 108mm 6 7 8 175mm 35 7 8 912 mm Overall Fireplace Width Outside Finish 3 76 mm Ma...

Страница 40: ...learance to Corner of Unit 2 3 4 70mm Non combustible Height 10 254mm Important Framing height requires consideration of the hearth height Dimension N N the thickness of the installed hearth S S U T V Q P M N O Combustible header R Top Vent Rear Vent W Corner Top Vent Only IMPORTANT Corner applications are vented from the top only rear venting cannot be used S1 The framing depth width does not tak...

Страница 41: ...Grandview G800EH Gas Fireplace 41 installation Outside Finish Finishing Finishing Material may be brought to the top and side edges of the fireplace as show below ...

Страница 42: ...wotabs per nailing flange These tabs are used to stop finishing material from interfering with the faceplate mounts Faceplate Finishing The finishing material can be brought to the top of the fireplace A 1 2 gap must be maintained on the sides to allow the Faceplate to be installed The finishing material must not protrude past the front face of the fireplace Follow the steps below to install Top a...

Страница 43: ...ng the arms on the Face Plate on top of the mounting tabs Adjust left and right to center the Face Plate NOTE Do not to touch the faceplate without clean soft gloves Dirt or oils can be transferred onto the finish and become permanent Critical Finishing Gap A 1 2 gap must be maintained on the sides of the fireplace to allow the Face Plate to be installed and removed Do NOT finish past the front fa...

Страница 44: ... tab on the top into the slot on the right 5 Fold the tab down to secure Right Side Finishing Trim Install Instructions 1 Bend the four tabs on the outer box front forward There are two tabs per side These tabs are the mounts for the faceplate or finishing trim 2 Bend the two tabs on the top nailing flange down 3 Bend the tabs on the left and right nailing flanges forward There are two tabs per na...

Страница 45: ...lange Tabs folded down 3 4 Finishing Trim Top View Mounting Tab Folded forward Nailing Flange folded forward Install the faceplate by resting the arms on the finishing trim on the top of the mounting tabs Adjust left and right to center the finishing trim Critical Finishing Gap Side View A 1 2 gap must be maintained on the sides and top of the fireplace to allow the finishing trim to be installed ...

Страница 46: ...nces are maintained WARNING Risk of Fire Maintain specified air space clearances to combustibles Inadequate air space could cause overheating and fire The appliance is designed to be used with 1 2 in wall sheathing materials such as drywall plywood wood composites or non combustible materials Thicker materials may be used Refer to facing and finishing details in this manual Facing Material Facing ...

Страница 47: ...ent systems are prohibited Vent Restrictor Installation tooltip Diagram 2 Vent restrictor located on top exhaust assembly 1 Determine the venting configuration 2 Go to venting arrangements section in the manual to determine if a vent restrictor setting is required If required proceed to Step 3 3 Loosen the two screws that secure the top heat deflector and remove top heat deflector diagram 1 Set 0 ...

Страница 48: ...ded above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on public p...

Страница 49: ... A N A 4DAL N A TC 4DLT N A Adjustable Length 3 10 Black N A N A N A 4DALB N A TC 4DLTB N A Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dL...

Страница 50: ...ent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Terminal 640 530 P Riser Vent Terminal 946 523 P AstroCap Horizontal Cap 946 206 Vinyl Siding Standoff for AstroCap The rigid pipe adaptor is not required on the C34 C34E U39 U39E H15 H27 H35 RC500E Note When using Metal Fab Sure Seal Rigid Piping please note that the Adaptor 4DDA mu...

Страница 51: ...us vent maximum horizontal length of 2ft 0 6 m Note Must use optional rigid pipe adaptor Part 510 994 when using Rigid Pipe vent systems Maintain clearance to combustibles For all other venting arrangements see Venting Arrangements Horizontal Termination Rigid Pipe and Direct Vent System Flex in this manual 2 0 12 6 4 8 10 2 0 6 4 8 Vertical Height Feet Rigid 44 1 1m Horizontal Feet Max 24 0 6m Fl...

Страница 52: ... 1 6 7 8 dia flexible liner 4 ft length 2 4 dia flexible liner 4 ft length 3 spring spacers 4 4 thimble 2 5 AstroCap termination cap 1 6 screws 12 7 tube of Mill Pac 1 8 plated screws 8 9 screws 8 x 1 1 2 Drill Point Stain less Steel 4 1 6 7 8 dia flexible liner 10 ft length 2 4 dia flexible liner 10 ft length 3 spring spacers 7 4 thimble 2 5 AstroCap termination cap 1 6 screws 12 7 tube of Mill P...

Страница 53: ...ect Vent Ameri can Metal Products Olympia Ventis DV Security Secure Vent AmeriVent Direct Vent AstroCapTM is the proprietary trademark of FPI Fireplace Products International Ltd Dura Vent and Direct Vent are registered and or proprietary trademarks of Simpson Dura Vent Co Inc This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with DuraVent Direct Vent Selkir...

Страница 54: ...o 45o elbows equal one 90o elbow Note Must use optional rigid pipe adaptor Part 510 994 when using Rigid Pipe venting systems All Rigid Pipe Systems 4 inner diameter 6 5 8 outer diameter FPI Flex Vent 4 inner diameter 6 7 8 outer diameter Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall...

Страница 55: ...cal Flex Kit to Same Limitations Propane Natural Gas The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations using two 90o elbows with rigid pipe vent systems for Propane and Natural Gas 2 2 6 6 1 10 0 4 4 8 8 1 12 2 Vertical Height Feet Horizontal Feet 8 8 1 10 0 1 12 2 1 14 4 1 16 6 1 18 8 2 20 0 2 22 2 2 24 4 2 26 6 2 28 8 3 30 0 ...

Страница 56: ... 1 22 m Min 6 1 82 m Max F 5 1 52 m Min 7 2 13 m Max G 6 1 82 m Min 8 2 44 m Max Restrictor Set 0 fully open Lengths do not include elbows indicated Required when using rigid venting One 90o elbow Two 45o elbows Option V H V V1 H H1 With these options max total pipe length is 30 feet 9 14 m with min of 12 feet 3 66 m total vertical and max 9 feet 2 79 m total horizontal Please note min 1 foot 0 3 ...

Страница 57: ...ini mum 1 foot between 90o elbows is re quired A 0 Min 2 Max 1 Min B 1 Min 4 Max 3 Min C 2 Min 5 Max 4 Min D 3 Min 6 Max 5 Min E 4 Min 7 Max 6 Min F 5 Min 8 Max 7 Min Lengths do not include elbow indicated Required when using rigid venting One 90o elbow Two 45o elbows Option V H H1 V V1 With these options maximumtotalpipelength is 30 feet with minimum of 10 feet total vertical and maximum 8 feet t...

Страница 58: ...et air collar of the termination cap Required Parts Part Description 946 529 Co linear DV Vertical Termination Cap 948 305 3 Flex 35 ft 946 563 Co Axial to Co Linear Adapter Kit which contains the following Co linear Flex Adapter Outer Pipe Inner Pipe Adapter 510 994 Rigid Pipe Adapter Alternate Approved Caps 46dva VC Vertical Termination Cap 46dva VCH High Wind Cap 46dva GK 3 Co linear Adapter wi...

Страница 59: ...aces Propane Natural Gas FOR BOTH RESIDENTIAL MANUFACTURED HOMES 30 Max 8 Min 44 3 4 30 Horizontal Distance Feet Vertical Height feet 8 Min 44 30 Max 30 Horizontal Distance Feet Vertical Height feet 2 max Combined min of 8 6 max 44 Combined max of 30 30 Horizontal Distance Feet Vertical Height feet 2 max Restrictor at Set 1 2 open ...

Страница 60: ...to the manufacturer sinstructionsincludedwith the components 1 Set the unit in its desired location Check to determine if wall studs or roof rafters are in the way when the venting system is attached If this is the case you may want to adjust the location of the unit Rough in the gas preferably on the right side of the unit and the electrical junction block is on the left side on the left 2 Direct...

Страница 61: ...ng to the position of theapplianceflue exit and mark the location where the vent will penetrate the ceiling Drill a small hole at his point Next drop a plumb bob from therooftothehole previously drilled in the ceiling and mark the spot where the vent will penetrate the roof Determine if ceiling joists roof rafters or other framing will obstruct the venting system You may wish to relocate the appli...

Страница 62: ...n d framing out a square to mount the terminal to Outside Wall Mur extérieur Furring Strips Fourrures en bois Furstrp eps see also c34020a eps furstrpf eps french Offset Chart Direct Vent System Flex Installation Procedures 1 Locate the unit in the framing rough in the gas preferably on the right side of the unit and the electrical Junction block is on the left side on the left Locate the centerli...

Страница 63: ...pe adaptor by using Mill Pac over the adaptor Slide the inner pipe over adaptor and secure with 3 screws 12 Repeat Step 11 to secure outer flex Diagram 4 14 Put a bead of caulking on the exterior between the outer pipe and flashing to prevent water from penetrating the chimney system 15 Slide storm collar over pipe length until it reaches the flashing 16 Install termination cap by twist locking it...

Страница 64: ...ram 1 Diagram 1a Diagram 1a Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Firestop spacer to prevent debris from falling into the ceiling firestop CEILING FIRESTOP FIRESTOP SPACER PART 946 757 Used in conjunction with the 946 755 Vertical Flex Kit and 946 ...

Страница 65: ... Sheet Installation of LP Conversion Kit 11 Re install pilot cap and pilot retainer clip 12 Remove burner orifice with a 3 8 wrench Useanotherwrenchtoholdontotheelbow behind the orifice Discard orifice 8 Remove the pilot retainer clip below the pilot cap 10 Unscrew the pilot orifice with the Allen key then replace with the LPG pilot orifice provided in the kit Pilot retainer clip 9 Pull off the pi...

Страница 66: ...to the front of the unit with the two screws showing 18 Loosen the two screws that secure the cover plate to the IFC mount Then remove the cover plate 19 The IFC can now be slid out from under the firebox 20 Disconnect the cable coming from the pressure regulator motor at the IFC board marked X6 on the IFC Cable from motor LP Conversion 21 Remove regulator from gas valve and dis card 2 Pressure re...

Страница 67: ... the firebed grate media vermiculite embers and logs until the brick panels are installed Brick panels will discolor a little during normal operation This is normal and should not be considered a defect 3 Loosen 2 screws on pilot assembly in locations shown below Slide pilot shield towards the back of the unit and remove from unit 8 Repeat Steps 5 7 on the left side 9 Slide the bottom panel carefu...

Страница 68: ...little during normal operation This is normal and should not be considered a defect All hand and fingerprints MUST be cleaned off with a soft cloth Use an ammonia based cleaner ie glass cleaner to remove any fingerprints before applying heat to the unit Failure to do this will result in burn stains on panels which you will be unable to remove Not protected by product warranty G800 3 Loosen 2 screw...

Страница 69: ... use the unit until they are replaced Broken logs can interfere with the pilot operation The G800 log sets 761 930 for Oak 761 932 for Birch contain the following pieces 1 6 8 2 3 4 9 11 5 10 12 7 NOTE Panels brick steel orenamel mustbeinstalled prior to installing the log set 1 Carefully remove the logs from the box and unwrap them The logs are fragile handle with care do not force into position ...

Страница 70: ... be pulled forward and to the right while contacting the end and curved parts of the burner 6 Install Log 2 on left log support plate Line up the pins on the plate with the pin hole on the log 7 Install Log 3 on right log support plate Line up the pins on the plate with the pin hole on the log 8 Install Log 4 diagonally across Log 2 Rest Log 4 in the notch out on Log 2 as shown Diagram 5 Install L...

Страница 71: ... of Log 7 should land on the pin of Log 1 The bottom of Log 7 will rest on the log grate 12 Install Log 8 at the front of the log grate The cutouts in Log 8 should rest in the 4th 5th prongs from the right of the log grate 13 Install Log 9 to the right of Log 5 The cutout in Log 9 will rest in the 2nd prong from the right on the log grate Diagram 13 Install Log 7 Diagram 11 Install Log 5 Diagram 1...

Страница 72: ... of the log grate on the firebox floor as shown 16 Install Log 12 on the firebox floor slide under Log 7 as shown 17 Testfiretoensureproperlightoff makesureflameflowssmoothly If there is any flame hesitation check that area for any blockage of the burner ports Diagram 17 Install Log 11 Diagram 19 Final Installation Diagram 18 Install Log 12 12 7 11 G800 ...

Страница 73: ...ayer Important ensure that at least 50 of the gas burner porting remains uncovered Do not cover the pilot area BURNER PORTING PILOT 4 If using volcanic stones as additional media add a maximum of 13 as shown below Important Volcanic stones should not cover any of the gas burner porting or pilot areas Note The optional brick steel or enamel panels must be installed prior to the crystal tray 1 Place...

Страница 74: ...ray and the back of the log should touch the back firebox panel 5 Add the supplied grey and black ember media 1 5 lbs total and spread it across the tray and around the stones in an even layer 1 Place the media tray over the burner as shown below 4 Add the three supplied stones to the tray in the locations shown The stones must not cover the burner porting IMPORTANT 1 Ensure that at least 50 of th...

Страница 75: ...e on the underside of Log 2 7 Place Log 3 in the front right area of the tray as shown 8 Place Log 4 on the right hand side of the tray as shown Ensure the right pin of Log 1 slots into the hole on the underside of Log 4 9 Place Log 5 in the front left area of the tray as shown Important Ensure no logs cover the gas burner porting area 10 To remove the driftwood media kit and media tray reverse th...

Страница 76: ...uld be carried out with the unit burning and the setting should be within the limits specified on the safety label 6 When finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but do not over tighten High Elevation This unit is approved in Canada for altitude to 4500ft CSA 2 17 ForNaturalGasinstal...

Страница 77: ...volt power will not be used Batteries usually serve as a secondary power source Insert the 4 AA type bat teries in the battery compartment with the correct polarity 6 Place the slider into the cover plate 7 Put the battery holder switch in the OFF position to allow correct lineup for slider switch 8 Make sure the battery holder and cover plate words ON and UP are on the same side 9 Align the slide...

Страница 78: ...y Pull lever forward to open push back to close Air shutter lever located in the center of the unit under the firebox Electrical Access and Installation The electrical access panel is on the right side of the unit when facing the front of unit 1 Remove panel by removing three 3 screws 2 Remove center knockout to run cable through the access panel and install supplied clamp 3 Attach wires from cabl...

Страница 79: ...Item Part Description 23 911 337 P Battery Holder 24 911 190 Stepper Motor NG 25 911 011 Stepper Motor LP 26 911 188 Valve NG 911 085 Valve LP 27 911 193 Jumper Wire 28 910 404 P Optional Programmable Wall Thermostat 28 910 407 Optional Basic Wall Thermostat CAUTIONS Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify prope...

Страница 80: ...flame height This is the recommended procedure for operating the unit with a thermostatic set point If a millivolt wall thermostat is required for bedroom installation or as a preferred method of controlling the stove see noted option Wall thermostat and remote Set the wall thermostat to the desired set point then place the remote transmitter in either SMART or thermostatic mode with a set point 5...

Страница 81: ...ground lug located in lower right corner of unit Refer to wiring diagram FAN INSTALL AFTER UNIT INSTALLATION Diagram 5 DFC wires Diagram 6 ground wires 3 From the back of the unit remove 4 screws from the fan access panel locations shown below 4 Connect red black fan wires to corresponding red black wires on the IFC box as shown 5 Connect fan ground cable to ground lug located in lower right corne...

Страница 82: ...ors on a regular basis by vacuuming out the fan blades and housing using a soft brush nozzle Diagram 7 Diagram 10 Diagram 8 Diagram 9 Fan Install After Unit Installation 1 The fan may be installed after the unit has been installed and fin ished Ensure the unit is turned off and has cooled to room tempera ture 2 Shut off the power and gas to the unit 3 Remove the screen and glass door See sections ...

Страница 83: ...cold and the appli ance is lit it may cause condensation and fog the glass This condensation is normal and will disappear in a few minutes as the glass heats up DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT DO NOT BURN THE UNIT WITHOUT THE GLASS DOOR IN PLACE First Fire Normal Operating Sounds of Gas Appliances It is possible that you will hear some sounds from your gas appliance This is...

Страница 84: ... 3 STEP 4 Reinstall wall cover plate with 2 Phillips head screws Replace 4 x AA batteries and insert the battery compartment back into remote receiver battery holder Move both the left right slides as shown below The battery compartment will be pushed out slightly to allow to easily extract it Extract the battery compartment from the remote receiver battery holder Close the right slide Keeping the...

Страница 85: ...tement le bâtiment Appelez immédiatement votre fournisseur de gaz depuis un téléphone extérieur Suivez les instructions du fournisseur Si vous ne pouvez pas rejoindre le fournisseur appelez le service incendie C N utilisez pas cet appareil s il a été plongé dans l eau même partiellement Faites inspecter l appareil par un technicien qualifié et remplacez tout élément du système de contrôle ou de co...

Страница 86: ... off the gas valve before cleaning Forrelighting refertolightinginstructions Keep the burner and control compartment clean by brushing and vacuuming at least once a year When cleaning the logs use a soft clean paint brush as the logs are fragile and easily dam aged 2 Clean appliance and door with a damp cloth never when unit is hot Never use an abrasive cleaner The glass should be cleaned with a g...

Страница 87: ... 5 Reverse steps to reassemble unit 1 Turn off fireplace and wait until it has reached room temperature 2 Remove the Screen Barrier See Section Safety screen removal Instal lation 3 Remove the glass door See Section Glass door removal Installation 4 Remove the two screws with a Phillips head screwdriver as shown below 5 Remove the Top Light Casing by lifting up and out 6 Remove the old light bulb ...

Страница 88: ...y into position 2 Reinstall the 8 hold down screws 3 Hook up the EV1 and EV2 wires to the appropri ate connections on the valve 4 Install the burner assembly 5 Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector Do not use open flame for leak test ing 6 Fire up the unit temporarily 7 Check the manifold pressure 8 Reinstall the inner panels log grate l...

Страница 89: ...ack 7 Rotate the front of the IFC Box to the left 8 Pull the IFC Box to the front of the unit with the two screws showing 9 Remove the two screws that secure the Cover Plate to the IFC Mount Then remove the Cover Plate 10 The IFC can now be slid out from under the firebox 11 Reverse steps to reinstall Firebox hidden for clarity IMPORTANT Ensure 3 prong cord is disconnected from receptacle located ...

Страница 90: ...should be checked by a licensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Operational changes to look for can include but are not limited to extended start up time increased fan noise residue carbon build up white build up on the glass firebox increased operating noise etc Should any of...

Страница 91: ...elow 4V Replace with 4 x AA alkaline batteries Flame sense problem If the pilot flame is not detected or the flame sense system is not satisfied the RED LED light will pulse with 2 flashes until corrected Possible causes of flame sense problems The pilot is not engulfing the flame sense Pilot light shrinks in size The flame sense wire is not connected to the IFC module Proper grounding Flame sense...

Страница 92: ...92 Grandview G800EH Gas Fireplace parts list Main Assembly 16 14 1 11 13 10 15 21 19 17 20 18 2 3 4 5 6 7 8 9 29 28 12 22 23 24 25 25A 26 ...

Страница 93: ...over Wall Mount White 0 584 813 N S 911 343 Cover Wall Mount Black 0 584 812 N S 910 428 Receptacle Duplex White N S 910 430 Receptacle Cover Duplex Metal N S 904 687 Connector Clamp 3 8 CI 804 N S 911 337 P Remote Receiver Battery Holder 584 103 N S 918 835 Decal Logo Regency Flame Sit Remote N S 918 876 Decal Remote Quick Reference GTMF N S 948 099 Spring Compression 3 inch Long Zinc Plated LC 0...

Страница 94: ...sket Light Wire N S 761 161 Board Calcium Silicate 36 X 20 N S 761 129 Gasket Top Light G800 N S 761 088 Insulation Rear Enamel Steel Panel N S 911 290 P Fan motor Only Part Description N S 761 901 Brick Panel Standard Brown N S 761 903 Brick Panel Herringbone Brown N S 761 904 Brick Panel Castle Stone Grey N S 761 905 Brick Panel Standard Volcanic Black N S 761 907 Inner Panel Black N S 761 908 I...

Страница 95: ...Grandview G800EH Gas Fireplace 95 notes ...

Страница 96: ...Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled ...

Страница 97: ...nstallation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the appliance...

Страница 98: ...S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief de...

Страница 99: ...for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CAN...

Страница 100: ...100 Grandview G800EH Gas Fireplace warranty ...

Страница 101: ...Grandview G800EH Gas Fireplace 101 notes ...

Страница 102: ...102 Grandview G800EH Gas Fireplace notes ...

Страница 103: ......

Страница 104: ...___________________________ Installer ______________________________________________ Phone ______________________________________________ Date Installed __________________________________________ Serial _______________________________________________ Printed in Canada 2022 FPI Fireplace Products International Ltd All rights reserved ...

Отзывы: