Grandview® G600EC Gas Fireplace

  |    7

safety decal

This is a copy of the label that accompanies each Grandview™ G600EC Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. 

NOTE:

 Regency

®

 units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

Copy of Safety Decal

For the State of Massachusetts, installation 
and repair must be done by a plumber or 
gas fitter licensed in the Commonwealth of 
Massachusetts.

For the State of Massachusetts, flexible con-
nectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appli-
ances individual manual shut-off must be a 
t-handle type valve.

The  State  of  Massachusetts  requires  the 
installation of a carbon monoxide alarm in 
accordance with NFPA 720 and a CO alarm 
with battery back up in the same room where 
the gas appliance is installed.

Decal location

DO NOT REMOVE DECAL FROM UNIT.

Remove bottom cover—decal will 
be on the floor of the unit

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.

This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the 

United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See 

owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used. (Kit #761-969). Fan Part # 761-917.

Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur. Installer l'appareil 

selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes 

ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.

Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure 

si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est 

fournie.

This vented gas fireplace heater is not for use with air filters.                                                                           Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.                                                                                          

FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY                                                     

 POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIÉES AVEC

 

L'APPAREIL

For Use Only with Barrier (Part # 776-109/P)    

 

 

 

                                          Utiliser uniquement avec l’écran ( n° 776-109/P) 

 

                          

 

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE 

                     

543

543

DOOR  SEAL: Please

check  that the door is 

properly sealed

FPI Fireplace Products International Ltd. Delta, BC, Canada

Minimum Clearances to Combustibles / Rear Vent—Cool Wall-Clean Front 

Dégagements minimaux par rapport aux matériaux combustibles / évacuation 

arrière-mur froid-façade épurée

Serial No./ No de série

920-272b

Electrical supply/Alimentation électrique 115VAC, 1.5A, 60Hz.    

NOT FOR USE WITH SOLID FUELS / 

NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE

Made in Canada/ Fabriqué au Canada

Duplicate S/N

0" Clearance to combustibles from 

Top, sides, and bottom of unit 

0.5” Clearance to combustibles from 

rear of unit   

Mantel Clearances from 

Fireplace Opening / 

(A) 12” (305 mm) at max. depth

Side Wall Clearance from Fireplace 

Opening / 

B)  Min 6” (152 mm)

Ceiling from Top of Fireplace 

Opening:

C) Min. 44.25” (1124 mm) 

Mantel Depth:

D) Max. 12” (305 mm)

Alcove Clearances:

E) Min. Width 84” (2134 mm)   

F) Max. Depth 36” (914 mm) 

Minimum Vent Clearances:

Horizontal Top            2” (51 mm)

Horizontal Side          1-1/2” (38 mm)

Horizontal Bottom      1-1/2” (38 mm)

Vertical Vent              1-1/2” (38 mm)

(

See Instruction Manual for detailed instructions)

APPAREIL 

FONCTIONNANT AU GAZ PROPANE

Modèle 

-LP

G600EC

PROPANE GAS: Model G600EC-LP

       

NATURAL GAS: Model G600EC-NG

Minimum supply pressure

Manifold pressure high

Manifold pressure low

Orifice size

Minimum input

Maximum input

Altitude

Pression d'alimentation minimale

Pression manifold - haute

Pression manifold - basse

Taille de l'orifice

D bit calorifique minimal 

é

D bit calorifique maximal

é

Altitude

5.0"           WC/C.E.   (1.25 kPa)

3.8"           WC/C.E.   (0.94 kPa)

1.1"           WC/C.E.  (0.27 kPa)

#46     DMS   

11,500      Btu/h      3.37 kWh

21,000     Btu/h       6.15   kWh

0-4500      ft/pi 

    (0-1372 m)

Part #: 920-272

Colour: Everything black on grey except what is highlighted is printed red.

Size:  File@100% 9.117’’W x 6.045’’H

May 04/20 : Created Draft

September 10/20: Updated to include kW measurements provided by gas lab.

Oct. 07/20: Updated with HeatWave kit statement.

Pression d'alimentation minimale

Pression manifold - haute

Pression manifold - basse

Taille de l'orifice

D bit calorifique minimal

é

D bit calorifique maximal

é

Altitude

11"           WC/C.E.   (2.74 kPa)

10"      WC/C.E.   (2..49 kPa)

6.4"      WC/C.E.  (1.60 kPa)

#55      DMS   

16,500  Btu/h         4.84 kWh

20,500  Btu/h         6.01 kWh

0-4500    ft/pi          (0-1372 m)

         

Minimum supply pressure

Manifold pressure high

Manifold pressure low

Orifice size

Minimum input

Maximum input

Altitude

E

B

A

C

D

F

C #: 4001172

MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE

.

Listed/Nom:

 Vented Gas Fireplace Heater / Foyer au Gaz à Évacuation

Certified to/Certifi  pour: 

é

 ANSI Z21.88-2017 • CSA-2.33-2017

                                             CSA 2.17-2017

                    

Refer to Intertek's Directory of Building Products for detailed information.

Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek. 

APPAREIL 

FONCTIONNANT AU GAZ NATUREL

Modèle G600EC-NG

CSA P.4.1 Fireplace Efficiency (FE) /Efficacité énergétique des foyers (EEF) CSA P.4.1

Natural Gas / Gaz naturel :     64.8% 

Propane Gas / Gaz propane : 67.22% 

CANADIAN ENERGY 

PERFORMANCE 

VERIFIED

RENDEMENT 

ÉNERGÉTIQUE 

VÉRIFIÉ

EP5011169

Part No. 946-556 HeatWave Kit may be used. La trousse HeatWave (pièce no. 946-556) peut être utilisée.

Part #: 920-273a - Side B

Colours: Black on white,  except for parts indicated as being Red.    

   Punch out .25" hole top right corner where indicated.

Size: 

 

           100%

                         w- 6.52"                          h- 1

1.13"

                 May 4/20:     

 

Created decal

Sept. 10/20:

 

Updated decal to include kW/h provided by gas lab.

Oct 07/20:

 

Updated decal to include HeatW

ave statement.

Part #: 920-273b - Side 

A

Colours: 

 

Black on white,  except for parts indicated as being Red.

   

   

 

Punch out .25" hole top right corner where indicated.

Size: 

 

           

 100%

                         

 W

- 6.045" x L- 9.18"

                 May 4, 2020:

 

Created decal

Sept. 10/20:

 

Updated decal to include kW/h provided by gas lab.

Oct 07/20:

 

Updated decal to include HeatW

ave statement.

Material:

 

Printable white polyester 7mm

Start serial sequence @ 000001

NOTE: This is a double sided decal.

   

    

919-649

Part #: 919-649

Colours: Black on Grey

,  except for parts indicated as being Red.

   

   Punch out .25" hole top right corner where indicated.

Size: 

 

           100%

                         w- 6.52"                          h- 1

1.13"

                 Apr 05/16:     Created decal Apr

. 26/16:     

Added Fr

. Headers/warnings

   

    

w- 6.5"                          h- 1

1"

A)

   

This appliance is equipped with an ignition device which automatically lights the pilot. 

     Do not try to light the pilot by hand.

B) 

 BEFORE OPERA

TING

 smell all around the appliance area for gas. Be sure to smell 

next to the floor 

     because some gas is heavier than air and will settle on th

e floor

.

  

    

WHA

T T

O DO IF 

YOU SMELL

 GAS

Do not try to light any appliance.

-  

Do not touch any electric switch, do not use any phone in your building.

-  

Immediately call your gas supplier from a neighbours phone. Follow the gas supplier

’s instructions.

-  

If you cannot reach your gas supplier

, call the fire department.

C)  

 

Do not use this appliance if any part has been under water

.  Immediately call a qualified service 

      technician to inspect the appliance and replace any part of the control system and any         gas control which has been underwater

.

A)  

Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse. 

       Ne tentez pas d’allumer la veilleuse manuellement. 

B) 

  AV

ANT LA

 MISE EN MARCHE

, reniflez 

tout 

autour 

de 

l’appareil 

pour 

déceler 

une 

odeur 

de 

gaz. 

Reniflez 

au 

niveau 

du 

plancher

, car 

certains 

gaz 

sont plus lourds que l’air et peuvent s’accumuler au niveau du sol.

      

QUE F

AIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :

    • Ne tentez pas d’allumer l’appareil

    • Ne touchez à aucun interrupteur; n'utilisez pas de téléph

ones se trouvant dans le bâtiment.

    • 

Appelez immédiatement votre fournisseur de gaz depuis un téléph

one extérieur

. Suivez les instructions du fournisseur

.

    • Si vous ne pouvez pas rejoindre le fournisseur

, appelez le service incendie.

C)  

 

N’utilisez pas cet appareil s’il a été plongé dans l’eau, même 

partiellement. Faites inspecter l’appareil par un technicien qu

alifié et remplacez 

tout élément du système de contrôle ou de commande qui a été pl

ongé dans l’eau.

DO NOT REMOVE THIS INSTRUCTION PLA

TE

NE P

AS ENLEVER CETTE ÉTIQUETTE D’INSTRUCTIONS

TO TURN OFF GAS 

APPLIANCE  / POUR ÉTEINDRE UN 

APP

AREIL

 AU GAZ

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, 

ANSI Z223.1/NFP

A

 54, 

or Natural Gas and Propane Installation Codes, CSA

 B149.1. 

Cet appareil doit 

être installé 

conformément aux codes locaux, 

s’il 

y a lieu. 

En 

l’absence de tels codes, suivre le National 

Fuel 

Gas Code, 

ANSI Z223.1/NFP

A

 54, ou les Natural Gas and Propane Installation Codes, CSA

 B149.1.

CAUTION:  Hot while in operation. Do not touch. Severe burns may result. Due to high surface temperatures keep

 

children, 

clothing 

and 

furniture, 

gasoline 

and 

other 

liquids 

having 

flammable 

vapors 

away

. Keep 

burner 

and 

control

 

compartment clean. See installation and operating instructions accompanying appliance.

ATTENTION : Surfaces 

chaudes 

lorsque 

l’appareil 

est 

en 

marche. 

Ne 

pas 

toucher

. Risque de brûlures 

graves. 

En 

raison

 

des températures élevées, les enfants, les vêtements et le mobilier

, le carburant et tout autre liquide aux vapeurs

 

inflammables 

doivent 

être 

tenus 

éloignés 

de 

l’appareil. 

Nettoyer 

régulièrement 

le 

brûleur 

et 

le 

compartiment 

des

 

commandes. V

oir les consignes d’installation et d’utilisation fournies avec l’appareil.

W

ARNING: 

If 

you 

do 

not 

follow 

these 

instructions 

exactly

, a 

fire 

or 

explosion 

may 

result 

causing 

property 

damage,

 

personal 

injury 

or 

loss 

of 

life. 

Improper 

installation, 

adjustment, 

alteration, 

service 

or 

maintenance 

can 

cause 

injury 

or

 

property damage. Refer to the owner

’s information manual provided with this appliance. For assistance or additional

 

information consult a qualified installer

, service agency or gas supplier

.

AVERTISSEMENT 

: Quiconque 

ne respecte pas scrupuleusement les instructions 

de 

la présente notice 

risque 

de déclencher 

un incendie ou une explosion pouvant entraîner des dégâts matériels ou des blessures pouvant être mortelles.

Tout 

défaut 

d'installation, 

de 

réglage, 

de 

modification, 

de 

service 

ou 

d'entretien 

peut 

entraîner 

des 

blessures 

ou 

des 

dom

-

mages matériels. 

Reportez-vous au 

manuel 

d'utilisation 

fourni 

avec cet équipement. 

Pour 

obtenir 

de 

l'aide 

ou 

des informa

-

tions complémentaires, consulter un installateur ou un service 

d'entretien qualifié, ou le fournisseur de gaz.

1) Ensure the Main switch is in the ON position and/or the wall mounted battery holder (if equipped) is in the <REMOTE> positio

n.

2) Press and release the ON/OFF button on the remote handheld transmitter

. An audible beep should be heard from the receiver

. If not 

using the remote, the unit can also be turned on by sliding the battery holder switch to the <ON> position (if equipped).

3) 

After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner

.

4)  The unit will turn on.

Note: The first attempt to ignition will last approximately 60 s

econds. If there is no flame ignition (rectification) the board w

ill stop spark

-

ing for approximately 35 seconds. 

After this wait time, the board will start a second try for ignition by sparking for approximately 60 

seconds. If there is still no positive ignition after the second attempt the board will go into lock out. The system will need to be reset as follows (after going into lock out mode):

 

a)  

 W

ait 5 minutes - turn the system off by  pressing the ON/OFF butt

on on the remote.

 

b)  

 After approximately 2 seconds press the ON/OFF button again.

 

c)  Unit will repeat step 2.

1) S’assurer que le commutateur principal est en position ON et/ou que le bloc-piles mural (le cas échéant) est en position <RE

MOTE>.

2) 

 Appuyer sur la touche ON/OFF de la télécommande puis relâcher

. Un bip sonore retentira depuis le récepteur

. Si vous n'utilisez pas 

la télécommande, l'appareil peut également être allumé en faisant glisser le commutateur du bloc-piles sur la position <ON> (le

 cas 

échéant).

3) 

Après environ 4 secondes, le système d'allumage produira une ét

incelle pendant 60 secondes pour allumer le brûleur principal.

4)  L'appareil s’allumera.

Remarque : 

Au premier allumage, le système tente d’allumer les flammes pend

ant 60 secondes. Si l’essai est infructueux, le système 

fera une pause de 35 secondes. C’est ce qu'on appelle l'étape d

e rectification. Ce délai écoulé, le système tente à nouveau d'a

llumer les 

flammes en produisant des étincelles pendant 60 secondes. Si les

 flammes ne s’allument toujours pas, le système se met en mode v

er

-

rouillage.   

Il faut alors le réinitialiser en suivant les étapes ci-dessous (pour le déverrouiller) :

               

 

a)  

 Attendre 5 minutes et éteindre l’appareil en appuyant sur la touche ON/OFF de la télécommande.

               

 

b)  

 Attendre 2 secondes et appuyer encore une fois sur la touche ON/OFF

.                

 

 

c) L'appareil répètera l'étape 2.

1)

 

Press the ON/OFF b

utton on the remote

.

2)

 

If ser

vice is to be perf

ormed–y

ou m

ust disconnect po

wer and shut off gas to the unit.

1)

 

Appuy

er sur la touc

he ON/OFF de la télécommande

.

2)

 

 Lors de l'entretien de l'appareil, vous devez débrancher l'alimentation électrique et couper le gaz alimentant l'appareil.

LIGHTING INSTRUCTIONS / CONSIGNES D’ALLUMAGE

FOR 

YOUR SAFETY

 READ BEFORE LIGHTING

POUR VOTRE SÉCURITÉ – À LIRE 

AV

ANT LA

 MISE EN MARCHE

920-273b

920-273b

Содержание Grandview G600EC-LP

Страница 1: ...e gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier 920 271a FPI FIREPLACE PRODUCTS INTERNATIONAL LTD 6988 Venture St Delta BC Canada V4G 1H4 10 22 20 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowne...

Страница 2: ... the warmth and charm of a wood fireplace at the flick of a switch The Grandview G600EC has been approved by Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace ...

Страница 3: ...e current National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This appliance comes equipped with a dedicated 8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local codes The appliance when installed must be electrically grounded in accordance with local...

Страница 4: ... other spaces of the building 4 Close fireplace dampers 5 Turn on clothes dryers and any appliance not connected to the venting system Turn on any exhaust fans such as range hoods and bathroom exhausts so they are operating at maximum speed Do not operate a summer exhaust fan 6 Follow the lighting instructions Place the appliance being inspected into operation Adjust the thermostat so appliance is ...

Страница 5: ...erminations Flex Vent or Rigid Pipe 4 x 6 5 8 51 Rigid Pipe Venting Systems Horizontal or Vertical Terminations 52 Venting Arrangements Horizontal Termination Rigid Pipe and FPI Direct Vent System Flex 53 Venting Arrangements Vertical Termination Rigid Pipe System and Vertical Flex Kit to Same Limitations 54 Horizontal Terminations Two 2 90 Elbows 55 Horizontal Terminations Three 3 90o Elbows 55 V...

Страница 6: ...e table of contents Light Bulb Replacement Bottom Lights Top Light 85 Valve Replacement 86 IFC Replacement 87 Gas Appliance Maintenance 88 Main Assembly Diagram 89 Main Assembly Parts List 90 Optional Accessories 91 Warranty 92 Parts ...

Страница 7: ...ifold pressure high Manifold pressure low Orifice size Minimum input Maximum input Altitude Pression d alimentation minimale Pression manifold haute Pression manifold basse Taille de l orifice D bit calorifique minimal é D bit calorifique maximal é Altitude 5 0 WC C E 1 25kPa 3 8 WC C E 0 94kPa 1 1 WC C E 0 27kPa 46 DMS 11 500 Btu h 3 37 kWh 21 000 Btu h 6 15 kWh 0 4500 ft pi 0 1372m Part 920 272 ...

Страница 8: ...ectly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspec...

Страница 9: ... 24 7 8 631mm 9 3 4 246mm 28 3 8 719mm FIREPLACE OPENING 8 3 8 213mm 14 5 8 372mm 16 406mm 4 101mm 6 3 4 172mm ELECTRICAL INLET GAS INLET ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS 37 3 4 959mm 34 3 4 883mm 37 1 2 953mm 34 5 8 880mm Finishing Trim Faceplate 30 7 8 784 mm 33 3 4 857 mm 33 1 2 851 mm 30 5 ...

Страница 10: ...AFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE YOUNG CHILDREN SHOULD BE CARE FULLY SUPERVISED WHENTHEY ARE IN THE SAME AREA AS THE APPLI ANCE TODDLERS YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENTAL...

Страница 11: ...d Pilot a safety feature which will shut down the gas valve completely by extinguishing the pilot light in the event of a continuous full seven days of inactivity This only applies if the CPI continuous pilot switch is in the on position in your remote control transmitter Each time the main burner shuts down manually or through the call from the thermostat the seven day timer starts again The seve...

Страница 12: ...nts les vêtements et le mobilier le carburant et tout autre liquide aux vapeurs inflammables doivent être tenus éloignés de l appareil Nettoyer régulièrement le brûleur et le compartiment des commandes Voir les consignes d installation et d utilisation fournies avec l appareil WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal in...

Страница 13: ...e of standing or intermittent pilot CPI IPI 4 Thermostat and Smart thermostat functions 5 Accent light modulation 6 levels 6 Split flow valve 7 Comfort Fan speed modulation 6 levels This feature is not available on any Hampton models IMPORTANT The Proflame Transmitter 2 is an integrated part of the Proflame 2 System which consists of these elements Proflame 2 Transmitter to be used in conjunction ...

Страница 14: ... step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position Fig 7 8 A single beep will confirm reception of the command Fig 7 Fig 8 Room Thermostat Transmitter Operation The Remote Control can operate as a room thermostat The thermos...

Страница 15: ...djust the fan speed fig 14 A single beep will confirm reception of the command Figure 13 Figure 14 Remote Dimmer Control Bottom Ember Lights The bottom ember lights are located near the dimmable light control To activate this function use the Mode Key fig 1 to index to light bulb fig 15 16 The intensity of the output can be adjusted through six 6 levels Use the Up Down Arrow Keys Fig 1 adjust the ...

Страница 16: ...ed from an intermittent pilot ignition system IPI to a continuous pilot ignition system CPI by using remote control as noted above The benefits of having as CPI are as follows Keeps venting primed for trouble free start up under colder weather conditions or inversions Keeps the unit glass warm which decreases the amount of condensa tion on start up Provides owners with flexibility to choose a trad...

Страница 17: ...nstallation Glass Door Removal To install the door Reverse steps above 1 To remove the glass door place both hands on either side of the latch Pull forward then up to unlock repeat on opposite side Important After releasing the latches support the weight of the door 2 With both latches released support the door with both hands and tilt out to approximately a 60 degree angle 3 Lift the door up and ...

Страница 18: ...he installation It is the responsibilityoftheinstallertoensurethisfireplace is installed in compliance with manufacturer s instructions and all applicable codes General Safety Information 1 The appliance installation must conform with localcodesor intheabsenceoflocalcodes with the current Canadian or National Gas Codes CAN1 B149 or ANSI Z223 1 Installation Codes 2 The appliance when installed must...

Страница 19: ... vent this must be completed prior to installing the appliance into the framed opening 3 Install vent Refer to Venting sections 4 Makegasconnections Testthepilot Mustbe as per Diagram Refer to Pilot Adjustment section Convert to propane if desired Refer to Gas Line Installation and Conversion Kit from NG to LPG sections 5 Make electrical connections to receptacle supplied with unit recommended 6 I...

Страница 20: ...ool Wall Installation Combustible Finishing Non Combustible Installation Unit Assembly Prior to Installation Cool Wall Clearances Cool Wall Mantel Clearances Cool Wall Mantel Leg Clearances Cool Wall Installation Framing Cool Wall Installation Cool Wall Conversion Chase Venting Chase Vent Installation Cool Wall Clean Front Installation Non Cooll Wall Clearances Clean Front Installation Non Cooll W...

Страница 21: ...bustible Installation Clean Front Install Non vented chase Non combustible board required Combustible framing Cool Wall Install Vented chase Combustible material can be used all around the fireplace Combustible framing Clean Front Clean Front Outside Finish w Finishing Trim Outside Finish w Faceplate ...

Страница 22: ...ed including the backing material The depth of finishing material can be adjusted in 1 4 in crements 1 If venting the unit in a top vent configura tion first intall the top vent heat shield with two screws as shown 2 Determine the required depth setting for the materials being used 3 Once the setting has been chosen install the Left and Right Nailing Flanges with 2 screws on each Flange Nailing Fl...

Страница 23: ...t _ Finishing Material Depth Flush 11 4 3 4 1 4 Setting Front of Fireplace I I 0 I 0 0 0 0 0 0 0 0 Top Nailing Flange Nailing Flange Installation 4 Screw one screw into the rear hole on each Side Nailing Flange 5 Install the Top Nailing Flange with 4 screws ...

Страница 24: ... Drywall etc Distance to combustible material varies with install OUTSIDE FINISH Finishing Material Backing Material Drywall etc Flush Finishing Material CLEAN FRONT Header Deflector 1 1 4 Max 6 Slot the Header Deflector onto the back screws then secure the with a screw through the remaining front hole on each flange ...

Страница 25: ...in 1 25 mm Top of Fireplace Opening B Sidewall 6 152 mm Side of Fireplace Opening C Ceiling 44 1 4 1124 mm Top of Fireplace Opening D Mantel Depth max 12 305 mm Front of Fireplace Opening E Alcove Width 84 2134 mm Wall to Wall Minimum F Alcove Depth 36 914 mm Front to Back Wall Maximum G Convection Air Outlet 58 in2 375 cm2 Top Front of Enclosure H Convection Air Outlet Opening Offset 0 2 0 51 mm ...

Страница 26: ...4 235 mm 5 1 2 140 mm 1 25 mm Combustible Mantel Clearances 2 0 12 6 4 8 10 0 Top of Fireplace Opening 12 305 mm 1 51 mm 7 178 mm A B 14 To Floor 5 10 Inches C D Mantel leg Allowable mantel leg projection TopView Side opening of fireplace Mantel leg Mantel leg 2 51 mm 3 76 mm 1 3 4 44 mm 28 3 4 729 mm overall fireplace width see note above Clean Finish 5 127 mm 6 152 mm Cool Wall Mantel Leg Clearanc...

Страница 27: ...op Vent Vent Centerline Height Top 39 1 2 1003 mm T Gas Connection Height 1 7 8 48 mm U Gas Connection Inset 8 3 8 213 mm V Gas Connection Width 3 1 2 89 mm W Clearance to Corner of Unit 1 2 13 mm Important Framing height requires consideration of the hearth height Dimension N N the thickness of the installed hearth P R M N O S S U T V Combustible header Top Vent Rear Vent W Q Note The 2 standoffs...

Страница 28: ... side of the unit with one screw as shown 7 Loosen the two outermost screws which are accessed through the holes in the locations show below NOTE Do not remove these two screws loosen them 8 Reach underneath the top of the unit and locate the lower sliding portion of the cool wall assembly Push this piece toward the back of the unit as far as it will go to open the cool wall air channel 4 Remove t...

Страница 29: ...emperatures This can be achieved in a number of ways including the examples shown below Warning DO NOT cover or place objects in front of the air outlets CHASE VENTING A minimum 58 in2 opening in the enclosure is required to maintain safe operating temperatures This can be achieved in a number of ways including the examples shown below Warning DO NOT cover or place objects in front of the air outl...

Страница 30: ...top of the chase vent opening must be 2 51 mm or less from the top of the chase enclosure Fasten the chase vent with screws and construction adhesive If the chase vent is not being used a minimum 58 in2 374 cm2 opening in the enclosure is required to maintain safe operating temperatures This can be achieved in a number of ways including a reveal at the top of the chase 08 11 20 920 150 G600EC 1 29...

Страница 31: ...ired clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions Minimum Vent Clearances to Combustibles G600EC Clearance Requirements Clearance Dimension Measured From A Mantel Height min 14 356 mm Top of Fireplace Opening B Sidewall 25 635 mm Side of Fireplace Opening C Ceiling 36 914 m...

Страница 32: ...g are shown in the Diagram on the right Note Ensure the paint that is used on the mantel and the facing is High Quality or the paint may discolour Mantel Clearances G600EC A B C D From Top of Fireplace Opening 28 3 8 721mm 23 584mm 19 1 4 489mm 14 356mm Combustible Mantel Clearances 0 5 10 0 Top of Fireplace Opening 12 305 mm 5 127 mm 17 432 mm A B 15 To Floor Inches C D Non Combustible Material M...

Страница 33: ...INISHING MATERIAL IN THIS AREA No Combustible Materials in this Area 33 1 2 851mm 13 331 mm 3 76mm 3 76mm 26 3 4 679 mm 1 5 8 41 mm 3 76mm See framing dimensions on next page Allowable mantel leg projection TopView Side opening of fireplace Mantel Mantel leg 38mm 4 1 4 108mm Leg 3 76mm 6 7 8 175mm 32 1 2 826mm Overall Fireplace width 1 1 2 2 38mm 51mm 28 3 4 729 mm Overall Fireplace Width Clean Fin...

Страница 34: ...Framed Chase Ceiling 43 1 2 1105 mm S Rear Vent Vent Centerline Height Rear 25 635 mm S1 Top Vent Vent Centerline Height Top 39 1 2 1003 mm T Gas Connection Height 1 7 8 48 mm U Gas Connection Inset 8 3 8 213 mm V Gas Connection Width 3 1 2 89 mm W Clearance to corner of unit 2 51 mm Non combustible Facing Height 13 330 mm Important Framing height requires consideration of the hearth height Dimens...

Страница 35: ...ing flanges see manual for instructions 2 Loosen the four 4 screws that secure the left and right nailing flanges to the unit 3 Slidetheleftandrighttilingflangesonto the front of the fireplace Use the slots to center with the screw securing the nailing flanges Diagram 1 4 Tighten screws 5 Slide the bottom tiling flange against thebottomofthefireplace Securewith a screw on each side 6 Finishing mat...

Страница 36: ...of chimney related fires is failure to maintain required clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions Minimum Vent Clearances to Combustibles G600EC Outside Finish Clearance Requirements Clearance Dimension Measured From A Mantel Height min 12 305mm Top of Fireplace Opening...

Страница 37: ...nces G600EC A B C D From Top of Fireplace 30 762mm 19 1 2 495mm 15 3 4 400mm 10 1 2 267mm Combustible Mantel Clearances 0 5 10 0 Top of Fireplace 12 305 mm 5 127 mm 17 432 mm A B 15 To Floor Inches C D Non Combustible Material Min 10 1 2 H 267mm 5 10 20 15 Outside Finish Installation Non Cool Wall Mantel Leg Clearances Allowable mantel leg projection TopView Side opening of fireplace Mantel Mantel ...

Страница 38: ... Ceiling 43 1 2 1105 mm S Rear Vent Vent Centerline Height Rear 25 635 mm S1 Top Vent Vent Centerline Height Top 39 1 2 1003 mm T Gas Connection Height 1 7 8 48 mm U Gas Connection Inset 8 3 8 213 mm V Gas Connection Width 3 1 2 89 mm W Clearance to Corner of Unit 2 51 mm Non combustible Height 10 1 2 267 mm Important Framing height requires consideration of the hearth height Dimension N N the thi...

Страница 39: ...Grandview G600EC Gas Fireplace 39 installation Outside Finish Finishing 29 7 8 758 mm 31 7 8 81 mm Finishing material may be brought to the top and side edges of the fireplace as show below ...

Страница 40: ... past the front face of the fireplace 3 4 19 mm Nailing Flange Tabs folded forward Mounting Tabs folded forward Mounting Tab Folded Forward Nailing Flange folded forward Framing Face Plate Install the faceplate by resting the arms on the Face Plate on top of the mounting tabs Adjust left and right to center the Face Plate NOTE Do not to touch the faceplate without clean soft gloves Dirt or oils ca...

Страница 41: ... Side Finishing Trim Install Instructions 1 Bend the four tabs on the outer box front forward There are two tabs per side These tabs are the mounts for the faceplate or finishing trim 2 Bend the two tabs on the top nailing flange down 3 Bend the tabs on the left and right nailing flanges forward There are two tabs per nailing flange Top and Side Nailing Flange Tabs See section NAILING FLANGE INSTA...

Страница 42: ... Top View Mounting Tab Folded forward Nailing Flange folded forward Install the faceplate by resting the arms on the finishing trim on the top of the mounting tabs Adjust left and right to center the finishing trim Critical Finishing Gap Side View A 1 2 13 mm gap must be maintained on the sides and top of the fireplace to allow the finishing trim to be installed and removed The finishing trim has ...

Страница 43: ...clearances are maintained WARNING Risk of Fire Maintain specified air space clearances to combustibles Inadequate air space could cause overheating and fire The appliance is designed to be used with 1 2 in 13 mm wall sheathing materials such as drywall plywood wood composites or non combustible materials Thicker materials may be used Refer to facing and finishing details in this manual Facing Mate...

Страница 44: ...im piece 2 Remove the intake cover plate from the rear by removing the top 2 screws and loosening the bottom 2 screws Diagram 1 Diagram 6 Diagram 9 Diagram 2 Diagram 3 3 Remove the exhaust cover plate from the rear by removing the top 4 screws and loosening the bottom 2 screws Hidden screw Diagram 4 4 Remove the intake collar from the top by removing 4 screws Diagram 5 Hidden screw Hidden screw 5 ...

Страница 45: ...inserting into the area on top of the exhaust cover plate Position it forward so that the insulation is held in place by the bend on the exhaust cover plate 8 Install the intake cover plate on top using the same screws that previously held the intake collar Diagram 12 9 Install the second piece of supplied insulation by inserting into the area on top of the intake cover plate Diagram 14 Diagram 15...

Страница 46: ... secure in place with the 4 top screws and then tighten the 2 bottom screws Diagram 16 11 Install the intake collar onto the rear Hang the collar onto the previously loosened bottom screws secure in place with the 2 top screws and then tighten the 2 bottom screws Diagram 18 12 Reinstall the collar trim with 6 screws Diagram 19 Diagram 17 Hidden screw ...

Страница 47: ...ust use it s own separate vent system Common vent systems are prohibited Vent Restrictor Installation Diagram 2 Vent restrictor located on top exhaust assembly 1 Determine the venting configuration 2 Go to venting arrangements section in the manual to determine if a vent restrictor setting is required If required proceed to Step 3 3 Loosen the two screws that secure the top heat deflector and remo...

Страница 48: ...ded above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on public p...

Страница 49: ...DAL N A TC 4DLT N A Adjustable Length 3 10 Black N A N A N A 4DALB N A TC 4DLTB N A Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLSI N A A...

Страница 50: ...ding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Terminal 640 530 P Riser Vent Terminal 946 523 P AstroCap Horizontal Cap 946 206 Vinyl Siding Standoff for AstroCap The rigid pipe adaptor is not required on the C34 C34E U39 U39E H15 H27 H35 RC500E Note When using Metal Fab Sure Seal Rigid Piping please note t...

Страница 51: ...h of 3ft 0 9m Note Must use optional rigid pipe adaptor Part 510 994 when using Rigid Pipe vent systems Maintain clearance to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall 2 0 12 6 4 8 10 2 0 6 4 8 Vertical Height Feet Rigid 39 1 2 1 1 m Horizontal Feet Max 36 0 9 m Flex 39 1 2 1 1 m Set 2 Set 1 24 0 61 m ...

Страница 52: ... Ameri can Metal Products Olympia Ventis DV Security Secure Vent AmeriVent Direct Vent AstroCapTM is the proprietary trademark of FPI Fireplace Products International Ltd Dura Vent and Direct Vent are registered and or proprietary trademarks of Simpson Dura Vent Co Inc This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with DuraVent Direct Vent Selkirk Direct...

Страница 53: ... Note Must use optional rigid pipe adaptor Part 510 994 when using Rigid Pipe venting systems Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall Note FPI Direct Vent Flex System Part 946 513 2 foot 0 61 m 946 515 4 foot 1 22 m and 946 516 10 foot 3 05 m only are approved for horizontal te...

Страница 54: ...Limitations Propane Natural Gas The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations using two 90o elbows with rigid pipe vent systems for Propane and Natural Gas 6 9 12 Vertical Height Feet Horizontal Feet 7 9 11 13 15 17 19 21 23 25 27 29 31 33 0 1 3 5 Set 3 1 1 2 open 0 Set 4 1 1 4 open Set 1 2 open 8 V Min 35 3 37 39 1 2 1 1 m...

Страница 55: ...lude elbows indicated Required when using rigid venting One 90o elbow Two 45o elbows Option V H V V1 H H1 With these options max total pipe length is 30 feet 9 14 m with min of 12 feet 3 66 m total vertical and max 9 feet 2 79 m total horizontal Please note min 1 foot 0 3 m between 90o elbows is required A 0 Min 1 0 3 m Max 1 0 3 m Min 2 0 61 m Max B 1 0 3 m Min 2 0 61m Max 3 0 91 m Min 3 0 91 m M...

Страница 56: ... 8 2 43 m Max 7 2 13 m Min Restrictor Set 1 2 51 mm open Lengths do not include elbow indicated Required when using rigid venting One 90o elbow Two 45o elbows Option V H H1 V V1 With these options maximum total pipe length is 30 feet 9 14 m with minimum of 10 feet 3 05m totalvertical and maximum 8 feet 2 44 m total horizontal Please note mini mum 1 foot be tween 90o elbows is required A 0 Min 2 0 ...

Страница 57: ...e attached to the inlet air collar of the termination cap Required Parts Part Description 946 529 Co linear DV Vertical Termination Cap 948 305 3 76 mm Flex 35 ft 10 67 m 946 563 Co Axial to Co Linear Adapter Kit whichcontainsthefollowing Co linear Flex Adapter Outer Pipe Inner Pipe Adapter Alternate Approved Caps 46dva VC Vertical Termination Cap 46dva VCH High Wind Cap 46dva GK 3 76 mm Co linear...

Страница 58: ...6 mm 30 Horizontal Distance Feet Vertical Height feet 8 2 44 m Min 39 1 2 1003 mm 30 9 14 m Max 30 Horizontal Distance Feet Vertical Height feet 2 0 61 m max Combined min of 8 2 44 m 6 1 82 m max 39 1 2 1003 mm Combined max of 30 9 14 m 30 Horizontal Distance Feet Vertical Height feet 2 0 61 m max IMPORTANT As shown below the unit can only be vented from the top not from the rear Restrictor at Set...

Страница 59: ... Installation If the Snorkel Termination must be installed below grade i e basement ap plication proper drainage must be providedtoprevent water from enter ing the Snorkel Termination Refer to Diagram 4 Do not attempt to en close the Snorkel within the wall or any other type of enclosure Unit Installation With Horizontal Termination Install the vent system according to the manufacturer s instructi...

Страница 60: ...otheposition of the appliance flue exit and mark the location Diagram 1 where the vent will penetrate the ceiling Drill a small hole at his point Next drop a plumb bob from the roof to the hole previouslydrilledintheceiling andmark the spot where the vent will penetrate the roof Determine if ceiling joists roof rafters or other framing willobstructthe ventingsystem You may wish to relocate the app...

Страница 61: ...o m m e n d framing out a square to mount the terminal to Outside Wall Mur extérieur Furring Strips Fourrures en bois Furstrp eps see also c34020a eps furstrpf eps french Offset Chart Direct Vent System Flex Installation Procedures 1 Locate the unit in the framing rough in the gas preferably on the right side of the unit and the electrical Junction block is on the left side on the left Locate the ...

Страница 62: ...pe to pipe adaptor by using Mill Pac over the adaptor Slide the inner pipe over adaptor and secure with 3 screws 12 Repeat Step 11 to secure outer flex Diagram 4 14 Put a bead of caulking on the exterior between the outer pipe and flashing to prevent water from penetrating the chimney system 15 Slide storm collar over pipe length until it reaches the flashing 16 Install termination cap by twist locki...

Страница 63: ... 1 Diagram 1 Diagram 1a Diagram 1a Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Firestop spacer to prevent debris from falling into the ceiling firestop A ceiling firestop firestop spacer must be installed when passing through each floor or ceiling level ...

Страница 64: ...ld on to the elbow behind the orifice Discard orifice 7 Remove the pilot retainer clip below the pilot cap 9 Unscrew the pilot orifice with the Allen key then replace with the LPG pilot orifice provided in the kit Pilot retainer clip 8 Pull off the pilot cap to expose the pilot orifice Diagram 2 Slide burner assembly to the right then remove 6 Remove three screws then remove the burner assembly 12...

Страница 65: ...ion of flame control 26 Reverse steps 4 1 18 Remove regulator and discard Install the Hi Lo pressure regulator onto the valve with 2 screws as shown below and also reconnect new cable from pressure regulator motor disconnected in step 19 Installer Notice These instructions must remain with the appliance 15 Rotate the front of the IFC box up and pull it out of the unit 16 Remove the two screws that...

Страница 66: ...tighten screw Note Do not install the firebed grate media vermiculite embers and logs until the brick panels are installed Brick panels will discolor a little during normal operation This is normal and should not be considered a defect tooltip Brick Clip Panel Inside top of firebox 3 Loosen 2 screws on pilot assembly in locations shown below Slide pilot shield towards the back of the unit and remo...

Страница 67: ...tion This is normal and should not be considered a defect All hand and fingerprints MUST be cleaned off with a soft cloth Use an ammonia based cleaner ie glass cleaner to remove any fingerprints before applying heat to the unit Failure to do this will result in burn stains on panels which you will be unable to remove Not protected by product warranty G600EC G600C tooltip Brick Clip Panel Inside to...

Страница 68: ...ced Broken logs can interfere with the pilot operation The G600EC G600C log sets 776 930 for Grandview Oak 776 932 for Grandview Birch contain the following pieces NOTE Panels brick steel or enamel must be installed prior to installing the log set 1 Carefully remove the logs from the box and unwrap them The logs are fragile handle with care do not force into position when installing 2 Install the ...

Страница 69: ...all Log 2 on left log support plate Line up the pins on the plate with the pin hole on the log 7 Install Log 3 on right log support plate Line up the pins on the plate with the pin hole on the log 8 Install Log 4 diagonally across Log 2 Rest Log 4 in the notch out on Log 2 as shown 9 Install Log 5 one end will rest in the notch out on Log 3 the Y end will rest on the 3rd prong from the right on th...

Страница 70: ... 8 at the front of the log grate The cutouts in Log 8 should rest in the 4th 5th prongs from the right of the log grate 13 Install Log 9 to the right of Log 5 The cutout in Log 9 will rest in the 2nd prong from the right on the log grate Diagram 12 Install Log 7 Diagram 13 Install Log 8 Diagram 14 Install Log 9 Diagram 11 Install Log 6 7 1 6 1 8 9 4 5 14 Install Log 10 as shown The flat bottom wil...

Страница 71: ...e flame flows smoothly If there is any flame hesitation check that area for any blockage of the burner ports Diagram 18 Final Installation Diagram 17 Install Log 12 12 7 G600EC G600C 16 Install Log 12 on the firebox floor near Log 7 as shown 1 12 2 3 4 5 6 7 8 9 10 11 Glass crystals must be placed at least 1 away from the front edge of the unit ...

Страница 72: ...72 Grandview G600EC Gas Fireplace installation 09 04 20 920 294 LOG SET INSTALLATION Page 5 of 4 Glass crystals must be placed at least 1 away from the front edge of the unit steel panels shown ...

Страница 73: ...ray in one even layer Important ensure that at least 50 of the gas burner porting remains uncovered Do not cover the pilot area BURNER PORTING PILOT 4 If using volcanic stones as additional media add a maximum of 10 as shown below Important Volcanic stones should not cover any of the gas burner porting or pilot areas Note The optional brick steel or enamel panels must be installed prior to the cry...

Страница 74: ...e unit burning and the setting should be within the limits specified on the safety label 6 When finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 3 mm flat screwdriver Note Screw should be snug but do not over tighten High Elevation This unit is approved in Canada for altitude to 4500 ft CAN CGA 2 17 M91 For Natural Gas installations a...

Страница 75: ...nect the 6 pin connector to the back of the Battery Holder 4 Install the Battery Holder in the Low Voltage Junction box 5 Install batteries only if 120 volt power will not be used Batteries are only used if power is lost within the home and serve as a secondary power source Insert the 4 AA type batteries in the battery compartment with the correct polarity 6 Place the slider into the cover plate 7...

Страница 76: ...ed under warranty Pull lever forward to open push back to close Air shutter lever located in the center of the unit under the firebox Electrical Access and Installation The electrical access panel is on the right side of the unit when facing the front of unit 1 Remove panel by removing three 3 screws 2 Remove center knockout to run cable through the access panel and install supplied clamp 3 Attach...

Страница 77: ... is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong recep tacle Do not cut or remove the grounding prong from this plug Note 4 AA Batteries must be installed into the back up battery compartment however for this unit to operate when power is lost See battery back up instructions in this manual...

Страница 78: ...y to operate as a thermostat With the addition of an optional wall cradle 820 477 AWT available from an authorized dealer the remote can reside on a wall and carry out all the func tions of a typical millivolt wall thermostat as well as control the fan speed and flame height This is the recommended procedure for operating the unit with a thermostatic set point If a millivolt wall thermostat is req...

Страница 79: ...ground lug located in lower right corner of unit Refer to wiring diagram FAN INSTALL AFTER UNIT INSTALLATION Diagram 5 DFC wires Diagram 6 ground wires 3 From the back of the unit remove 4 screws from the fan access panel locations shown below 4 Connect red black fan wires to corresponding red black wires on the IFC box as shown 5 Connect fan ground cable to ground lug located in lower right cor n...

Страница 80: ...floor access panel as shown 9 Lift out valve tray and set aside 10 Connect the fan to the IFC and ground follow Steps 4 6 from the previous page 11 Push the IFC towards the front of the unit to make room for fan install Install fan assembly onto 2 pins on unit floor located in the rear right section of the unit 12 Move the IFC back into place and reinstall the valve tray burner firebox media door ...

Страница 81: ...e cleaning NOTE When the glass is cold and the appliance is lit it may cause condensation and fog the glass This condensation is normal and will disappear in a few minutes as the glass heats up DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT DO NOT BURN THE UNIT WITHOUT THE GLASS DOOR IN PLACE First Fire Normal Operating Sounds of Gas Appliances It is possible that you will hear some sound...

Страница 82: ... Remove 2 Phillips head screws to remove cover plate Place screws to the side Cover plate may not be exactly as shown See Diagram 1 Diagram 2 Battery compartment door Battery compartment tabs 2 Press down on both tabs to remove battery compartment door See diagrams 2 and 3 Diagram 4 Diagram 3 Battery door removed 3 Install 4 AA batteries ensuring the polarity is correct See Diagram 4 4 Reverse ste...

Страница 83: ... régulièrement le brûleur et le compartiment des commandes Voir les consignes d installation et d utilisation fournies avec l appareil WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner ...

Страница 84: ...burner and control compartment clean by brushing and vacuuming at least once a year When cleaning the logs use a soft clean paint brush as the logs are fragile and easily dam aged 2 Clean appliance and door with a damp cloth never when unit is hot Never use an abrasive cleaner The glass should be cleaned with a gas fireplace glass cleaner The glass should be cleaned when it starts looking cloudy 3...

Страница 85: ...t Light Bulb Replacement Top Light 1 Turn off fireplace and wait until it has reached room temperature 2 Remove the Screen Barrier See Section Safety screen removal Instal lation 3 Remove the glass door See Section Glass door removal Installation 4 Remove the two screws with a phillips head screwdriver as shown below 5 Remove the Top Light Casing by lifting up and out 6 Remove the old light bulb b...

Страница 86: ... 3 Hook up the EV1 and EV2 wires to the ap propriate connections on the valve 4 Install the burner assembly 5 Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector Do not use open flame for leak test ing 6 Fire up the unit temporarily 7 Check the manifold pressure 8 Reinstall the inner panels log grate logs and media as needed 9 Reinstall the door and s...

Страница 87: ...the IFC box towards the front of the unit IMPORTANT Ensure 3 prong cord is disconnected from receptacle located on lower right hand side of appliance prior to servicing IFC Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing 6 Rotate the front of the IFC box up and pull it out of the unit 7 ...

Страница 88: ... service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Operational changes to look for can include but are not limited to extended start up time increased fan noise residue carbon build up white build up on the glass firebox increased operating noise etc Should any of these or other conditions arise di...

Страница 89: ...Grandview G600EC Gas Fireplace 89 parts list Main Assembly 18 20 17 19 22 25 12 27 24 26 26A 3 4 5 6 7 8 9 10 28 1 2 21 13 11 29 15 14 16 4 4a ...

Страница 90: ...ox Mounting Plate N S 910 369 Receptacle Box Low Volt SC100A N S 910 576 CoverWall MountWhite GTM SIT 0 584 803 N S 910 428 Receptacle Duplex White N S 910 430 Receptacle Cover Duplex Metal N S 904 687 Connector Clamp 3 8 CI 804 N S 911 187 Remote Receiver Battery Holder 584 103 N S 918 835 Decal Logo Regency Flame Sit Remote N S 918 876 Decal Remote Quick Reference GTMF N S 948 099 SpringCompress...

Страница 91: ...ium Silicate 32 W x 13 H N S 761 129 Gasket Top Light N S 776 064 Insulation Rear Enamel Steel Panel N S 911 290 P Fan motor Only N S 911 181 Fan Wire Grey N S 911 182 Fan Wire Red Part Description N S 776 901 Brick Panel Standard Brown N S 776 903 Brick Panel Herringbone Brown N S 776 904 Brick Panel Castle Stone Grey N S 776 905 Brick Panel Standard Volcanic Black N S 776 907 Inner Panel Black N...

Страница 92: ...Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled ...

Страница 93: ...nstallation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the appliance...

Страница 94: ...S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief de...

Страница 95: ...der for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in...

Страница 96: ...on Dealer Name Address _________________________________________ _____________________________________________________________ Installer ______________________________________________________ Phone ______________________________________________________ Date Installed _________________________________________________ Serial No _____________________________________________________ __________________...

Отзывы: