Grandview® G600EC Gas Fireplace
| 55
installation
Horizontal Terminations
Two (2) 90°Elbows
H
H1
V
Horizontal Terminations
Three (3) 90
o
Elbows
*
*
One 90
o
elbow = Two 45
o
elbows.
Option V
H + H1
With these options, maximum
total pipe length is 30 feet (9.14
m) with minimum of 6 feet (1.82
m) total vertical and maximum
8 feet (2.44 m) total horizontal.
Please note minimum 1 foot
(0.3 m) between 90
o
elbows
is required.
A)
0' Min.
2' (0.61 m) Max.
B)
1' (0.3 m) Min.
3' (0.91 m) Max.
C)
2' (0.61 m) Min.
4' (1.22 m) Max.
D)
3' (0.91 mm) Min. 5' (1.52 m) Max.
E)
4' (1.22 m) Min.
6' (1.82 m) Max.
F)
5' (1.52 m) Min.
7' (2.13 m) Max.
G)
6' (1.82 m) Min.
8' (2.44 m) Max
Restrictor Set #1 - 2" (51 mm) open. Lengths do not include elbows indicated.
*Required when using rigid venting.
One 90
o
elbow = Two 45
o
elbows.
Option V
H
V + V1
H + H1
With these options,
max. total pipe length
is 30 feet (9.14 m) with
min. of 12 feet (3.66
m) total vertical and
max. 9 feet (2.79 m)
total horizontal.
Please note min. 1
foot (0,3 m) between
90
o
elbows is
required.
A)
0' Min.
1' (0.3 m) Max. 1' (0.3 m) Min.
2' (0.61 m) Max.
B)
1' (0.3 m) Min.
2' (0.61 m) Max. 3' (0.91 m) Min. 3' (0.91 m) Max.
C)
2' (0.61 m) Min. 2' (0.61 m) Max. 5' (1.52 m) Min. 4' (1.22 m) Max.
D)
3' (0.91 m) Min. 2' (0.61 m) Max. 7' (2.13 m) Min. 5' (1.52 m) Max.
E)
4' (1.22 m) Min. 3 (0.91 m) Max. 9' (2.74 m) Min. 6' (1.82 m) Max.
F)
5' (1.52 m) Min. 4' (1.22 m) Max. 10' (3.04 m) Min. 7' (2.13 m) Max.
G)
6' (1.82 m) Min. 5' (152 m) Max. 11' (3.35 m) Min. 8' (2.44 m) Max.
H)
7' (2.13 m) Min. 6' (1.82 m) Max. 12' (3.66 m) Min. 9' (2.74 m) Max.
Restrictor Set #1 - 2" (51 mm) open. Lengths do not include elbows included.
*Required when using rigid venting
V1
H1
H
V