26 | Gi29 Direct Vent Gas Insert
installation
The burner aeration is factory set, but may need adjustment due to altitude
or the local gas supply.
Air shutters increase or decrease the amount of air mixed with fuel, af
-
fecting combustion and how the flame looks. Low primary air will create a
taller, yellower flame, and higher primary air a lower, bluer flame.
Air shutter adjustment is not just for appearance - not enough primary
air may lead to carboning, sooting, or a flame that reaches the top of the
firebox. Units that are burning propane, installed at higher elevations, or
run on high most of the time may need more primary air.
Unit
FuelType
Min. Air Shutter Setting*
Gi29L
NG
3/16" (5 mm)
Gi29L
LP
1/4" (6.35 mm)
*At higher elevations, air shutter settings may have to be opened
more to compensate.
AirShutterAdjustment
+
-
- Pull out to close air shutter
+ Pull in to open air shutter
CA
UTION
•
*Carbonwillbeproducedifairshutterisclosedtoo
much.
•
Aerationadjustmentshouldonlybeperformedbyan
authorizedRegencyinstalleratthetimeofinstallation
orservice.
•
Anydamageduetocarboningresultingfromimproperly
setting the aeration controls is NOT covered under
warranty.
Содержание Gi29L-LP
Страница 76: ...76 Gi29 Direct Vent Gas Insert warranty ...
Страница 77: ...Gi29 Direct Vent Gas Insert 77 ...
Страница 78: ...78 Gi29 Direct Vent Gas Insert ...