Regency FG39-1 FireGenie Freestanding Gas Stove
IMPORTANT:
SAVE THESE
INSTRUCTIONS
The REGENCY Room Sealed Freestanding
Gas Stove must be installed in accordance
AG601 and NZS 5261 and with these instruc
-
tions. Carefully read all the instructions in this
manual first. Consult the building authority
having jurisdiction to determine the need for a
permit prior to starting the installation.
Note: Failure to follow the instructions
could cause a malfunction of the
heater which could result in death,
serious bodily injury, and/or property
damage. Failure to follow these
instructions may also void your fire
insurance and/or warranty.
Note: These instructions take precedence
over Simpson Dura-Flue instruc-
tions.
SPECIFICATIONS
Fuels:
FG39NG1-BRA is approved for use with
NG.
FG39LPG1-BRA is approved for use
with liquefied petroleum gases (LPG).
Electrical:
240V A.C. system.
Circulation Fan:
Variable speed, 125/75.
Log Sets:
Ceramic fibre, 7 per set.
Flue System:
Coaxial (6-5/8" outer / 4" inner
liner) rigid flue and termination cap.
BEFORE YOU START
Safe installation and operation of this appliance
requires common sense, however, we are
required by the Canadian Safety Standards
and ANSI Standards to make you aware of
the following:
INSTALLATION
LINT FROM CARPETING, ETC.
IT IS IMPERATIVE THAT THE
CONTROL COMPARTMENT,
BURNERS AND CIRCULATING
AIR PASSAGEWAYS OF THE AP-
PLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES,
THE APPLIANCE SHOULD BE
LOCATED OUT OF TRAFFIC AND
AWAY FROM FURNITURE AND
DRAPERIES.
WARNING: FAILURE TO INSTALL
THIS APPLIANCE CORRECTLY
WILL VOID YOUR WARRANTY
AND MAY CAUSE A SERIOUS
HOUSE FIRE.
CHILDREN AND ADULTS SHOULD
BE ALERTED TO THE HAZARDS
OF HIGH SURFACE TEMPERA-
TURES, ESPECIALLY THE FIRE-
PLACE GLASS, AND SHOULD
STAY AWAY TO AVOID BURNS
OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD
BE CAREFULLY SUPERVISED
WHEN THEY ARE IN THE SAME
ROOM AS THE APPLIANCE.
CLOTHING OR OTHER FLAM-
MABLE MATERIAL SHOULD NOT
BE PLACED ON OR NEAR THE
APPLIANCE.
INSTALLATION AND REPAIRS
SHOULD BE DONE BY AN AU-
THORIZED SERVICE PERSON.
THIS APPLIANCE SHOULD BE IN-
STALLED, REPAIRED, INSPECT-
ED BEFORE USE AND AT LEAST
ANNUALLY BY AN AUTHOR-
IZED SERVICE PERSON. MORE
FREQUENT CLEANING MAY BE
REQUIRED DUE TO EXCESSIVE
page 6. This unit is approved for manufac
-
tured home installations, see page 9 for the
required flue arrangements. If installed into a
manufactured home the unit must be bolted
down to the floor.
4)
This appliance is Listed for bedroom instal
-
lations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
5)
This appliance is Listed for Alcove installa-
tions, maintain minimum Alcove clearances
as follows, minimum width of 48" (1219mm),
a maximum depth of 36" (914mm), and
minimum ceiling height of 64"(1626mm).
6)
We recommend that you plan your instal
-
lation on paper using exact measurements
for clearances and floor protection before
actually installing this appliance. Have an
authorized building inspector review your
plans before installation.
GENERAL SAFETY
INFORMATION
1)
The appliance shall be installed in accord-
ance with the manufacturer's installation
instructions,local gas fitting regulations,
municipal building codes, water supply
regulations, electrical wiring regulations, with
AS5601-2004 (AGA gas installation code)
NZS 5261 (New Zealand)
2)
Installation and repair should be done
ONLY by an authorised person.
3)
DO NOT CONNECT TO MASONARY
FLUE.
4)
This appliance must be connected to the
specified flue and termination cap to the
outside of the building envelope. Never
flue to another room or inside a building.
Make sure that the flue is fitted as per
Flueing instructions.
5)
Inspect the flueing system annually for block
-
age and any signs of deterioration.
6)
Flueing terminals shall not be recessed into
a wall or siding.
7)
Any safety glass removed for servicing must
be replaced prior to operating the appli-
ance.
8)
To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
fireplace.
9)
Wear gloves and safety glasses for protection
while doing required maintenance.
1)
Provide adequate clearances for servicing,
proper operation and around the air openings
into the combustion chamber.
2)
The appliance may be installed on a flat,
solid, continuous surface (e.g. wood, metal,
concrete). This may be the floor, or it can be
raised up on a platform to enhance its visual
impact. The appliance may be installed on
carpeting, tile, wood flooring or other com
-
bustible material, because the appliance's
metal pedestal base extends the full width
and depth of the appliance. The Regency
Room Sealed Freestanding Gas Stove can
be installed in a wide variety of ways and will
fit nearly any room layout. It may be installed
in a recessed position, framed out into the
room, or across a corner.
3)
The Regency Room Sealed Freestanding
Gas Stove is approved for alcove installa-
tions, which meet the clearances listed on
Содержание FG39LPG1-BRA
Страница 3: ...Regency FG39 1 FireGenie Freestanding Gas Stove 3 UNIT SPECIFICATIONS ...
Страница 35: ...Regency FG39 1 FireGenie Freestanding Gas Stove 35 NOTES ...
Страница 36: ...36 Regency FG39 1 FireGenie Freestanding Gas Stove WARRANTY ...
Страница 37: ...Regency FG39 1 FireGenie Freestanding Gas Stove 37 WARRANTY ...
Страница 38: ...38 Regency FG39 1 FireGenie Freestanding Gas Stove WARRANTY ...
Страница 39: ...Regency FG39 1 FireGenie Freestanding Gas Stove 39 WARRANTY ...
Страница 40: ...40 Regency FG39 1 FireGenie Freestanding Gas Stove WARRANTY ...
Страница 41: ...Regency FG39 1 FireGenie Freestanding Gas Stove 41 WARRANTY ...
Страница 42: ...42 Regency FG39 1 FireGenie Freestanding Gas Stove ...