Regency U31-10 Gas Fireplace Insert | 33
|
33
operating instructions
OPERATING
INSTRUCTIONS
Before operating this appliance, proceed through
the following check list.
1.
Read and understand these Instructions before
operating this appliance.
2.
Check to see that all wiring is correct and en
-
closed to prevent possible shock.
3.
Check to ensure there are no gas leaks.
4.
Make sure the glass door is in place. Never oper
-
ate the appliance with the door glass removed.
5.
Verify that all venting and the cap is unob-
structed.
6.
Verify log placement. If the pilot cannot be seen
when lighting the unit - the logs or the embers
have been incorrectly positioned.
7.
The unit should never be turned off and on
again without a minimum of a 60 second wait.
8.
When lighting the appliance, the inside of the
glass may fog up. This will burn off after a few
minutes of operation.
OPTIONAL WALL
THERMOSTAT
A wall thermostat may be installed if desired.
Connect the wires as per the wiring diagrams.
Note that the wires are connected to the "TH" on
the gas valve. Use table below to determine the
maximum wire length:
Note: Preferable if the thermostat is installed
on an interior wall.
FPI offers an optional programmable thermostat
but any 250-750 millivolt rated non-anticipator
type thermostat that is CSA, ULC or UL approved
may be used.
CAUTION
Do not connect the millivolt
remote control wires to
the 120V wires.
FINAL CHECK
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly. This includes:
1.
Clocking the appliance to ensure the correct
firing rate (rate noted on label) at 15 minutes.
2.
If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15 min. to stabilize.
CAUTION
Any alteration to the product that causes
sooting or carboning that results in damage
to the exterior facia is not the responsibility
of the manufacturer.
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
50 Ft.
16 GA.
32 Ft.
18 GA.
20 Ft.
20 GA.
12 Ft.
22 GA.
9 Ft.
CAUTION
Do not connect the millivolt
wall thermostat wires
to the 120V wires.
FIRST FIRE
The first fire in your stove is part of the paint curing
process. To ensure that the paint is properly cured,
it is recommended that you burn your fireplace
for at least four (4) hours the first time you use
it with the fan on. When first operated, the unit
will release an odour caused by the curing of the
paint, the burning off of any oils remaining from
manufacturing. Smoke detectors in the house may
go off at this time. Open a few windows to ventilate
the room for a couple of hours.
The glass panel may require cleaning after the unit
has cooled down.
DO NOT ATTEMPT TO CLEAN THE GLASS
WHILE IT IS HOT.
Note: When the glass is cold and the appli
-
ance is lit, it may cause condensation
and fog the glass. This condensation
is normal and will disappear in a few
minutes as the glass heats up.
DO NOT BURN THE APPLIANCE WITHOUT
THE GLASS FRONT IN PLACE.
820 Valve Description
1.
Gas on/off knob
2.
Manual high/low adjustment
3.
Pilot Adjustment
4.
Thermocouple Connection
5.
Main Operator
6.
Outlet Pressure Tap (Manifold Pressure)
7.
Inlet Pressure Tap (Supply Pressure)
8.
Pilot Outlet
9.
Main Gas Outlet
10.
Flange Securing Screw Holes
11.
Alternative TC Connection Point
12.
Thermoelectric Unit
13.
Additional Valve Mounting Hole
Содержание Energy U31
Страница 4: ...4 Regency U31 10 Gas Fireplace Insert 4 dimensions UNIT DIMENSIONS WITH STANDARD FACEPLATE ...
Страница 5: ...Regency U31 10 Gas Fireplace Insert 5 5 dimensions UNIT DIMENSIONS WITH LOW PROFILE FACEPLATE ...
Страница 46: ......
Страница 47: ......