background image

 

Regency U31-10 Gas Fireplace Insert  |     33

 

 

|

 

33

operating instructions

OPERATING 

INSTRUCTIONS 

Before operating this appliance, proceed through 

the following check list.

1.

  Read and understand these Instructions before 

 

operating this appliance.

2.

  Check to see that all wiring is correct and en

-

closed to prevent possible shock.

3.

  Check to ensure there are no gas leaks.

4.

  Make sure the glass door is in place. Never oper

-

ate the appliance with the door glass removed.

5.

  Verify that all venting and the cap is unob-

structed.

6.

  Verify log placement. If the pilot cannot be seen 

when lighting the unit - the logs or the embers 

have been incorrectly positioned.

7.

  The  unit  should  never  be  turned  off  and  on 

again without a minimum of a 60 second wait.

8.

  When lighting the appliance, the inside of the 

glass may fog up. This will burn off after a few 

minutes of operation.

OPTIONAL WALL

THERMOSTAT 

A  wall  thermostat  may  be  installed  if  desired. 

Connect the wires as per the wiring diagrams. 

Note that the wires are  connected to the "TH" on 

the gas valve. Use table below to determine the 

maximum wire length:

Note: Preferable if the thermostat is installed 

on an interior wall.

FPI offers an optional programmable thermostat 

but any 250-750 millivolt rated non-anticipator 

type thermostat that is CSA, ULC or UL approved 

may be used.

CAUTION

Do not connect the millivolt 

remote control wires to 

the 120V wires.

FINAL CHECK

Before  leaving  this  unit  with  the  customer,  the 

installer must ensure that the appliance is firing 

correctly. This includes:

1.

  Clocking the appliance to ensure the correct 

firing rate (rate noted on label) at 15 minutes.

2.

  If required, adjusting the primary air to ensure 

that the flame does not carbon. First allow the 

unit to burn for 15 min. to stabilize.

CAUTION

Any  alteration  to  the  product  that  causes 

sooting or carboning that results in damage 

to the exterior facia is not the responsibility 

of the manufacturer.

Thermostat Wire Table

Recommended Maximum Lead Length 

(Two-Wire) When Using Wall 

Thermostat (CP-2 System)

Wire Size

  

Max. Length

14 GA.

50 Ft.

16 GA.

32 Ft.

18 GA.

20 Ft.

20 GA.

12 Ft.

22 GA.

9 Ft.

CAUTION

Do not connect the millivolt 

wall thermostat wires 

to the 120V wires.

FIRST FIRE

The first fire in your stove is part of the paint curing 

process. To ensure that the paint is properly cured, 

it  is  recommended  that  you  burn  your  fireplace 

for at least four (4) hours the first time you use 

it with the fan on. When first operated, the unit 

will release an odour caused by the curing of the 

paint, the burning off of any oils remaining from 

manufacturing. Smoke detectors in the house may 

go off at this time. Open a few windows to ventilate 

the room for a couple of hours. 

The glass panel may require cleaning after the unit 

has cooled down.  

DO NOT ATTEMPT TO CLEAN THE GLASS 

WHILE IT IS HOT. 

Note:  When the glass is cold and the appli

-

ance is lit, it may cause condensation 

and fog the glass. This condensation 

is normal and will disappear in a few 

minutes as the glass heats up.

DO NOT BURN THE APPLIANCE WITHOUT 

THE GLASS FRONT IN PLACE.

820 Valve Description

1.

  Gas on/off knob

2.

  Manual high/low adjustment

3.

  Pilot Adjustment

4.

  Thermocouple Connection

5.

  Main Operator

6. 

Outlet Pressure Tap (Manifold Pressure)

7.

  Inlet Pressure Tap (Supply Pressure)

8.

  Pilot Outlet

9.

  Main Gas Outlet

10.

 Flange Securing Screw Holes

11.

 Alternative TC Connection Point

12.

 Thermoelectric  Unit

13.

 Additional Valve Mounting Hole

Содержание Energy U31

Страница 1: ...AS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas sup...

Страница 2: ...hic danger and statements shall be shown on a Class IIIA 2 Permanent Label 4 34 6 Instruction Plate Each appliance shall bear a Class IIIB marking with letters on a contrasting background located adjacent to the controlling device or in an equally conspicuous position where the instruction can be easily read April 22 14 Created draft Double sided Material Synthetic Paper Size 5 965 W x 5 71 H Colo...

Страница 3: ...Aeration System 23 Test for Flue Spillage 23 Optional Brick Panel 23 Log Set Installation 24 Wiring Diagram 27 Standard Faceplate Hearth Trim Install 28 Flush Louver Installation 29 Low Profile Faceplate Installation 30 Safety Screen Installation Removal 32 Optional Wall Thermostat 33 Final Check 33 Operating Instructions Operating Instructions 33 First Fire 33 Lighting Procedure 34 Shutdown Proce...

Страница 4: ...4 Regency U31 10 Gas Fireplace Insert 4 dimensions UNIT DIMENSIONS WITH STANDARD FACEPLATE ...

Страница 5: ...Regency U31 10 Gas Fireplace Insert 5 5 dimensions UNIT DIMENSIONS WITH LOW PROFILE FACEPLATE ...

Страница 6: ...ed to top or rear vent per manual instructions and the insulation discarded Venting YES NO Are the venting components approved for the unit installed Does the venting configuration comply with venting diagrams Is venting installed and secured and are clearances for the vent pipe and termination cap maintained If applicable was a 1 4 rise maintained for every foot of horizontal run Was the terminat...

Страница 7: ...utter on the proper setting after running the unit for 20 minutes If applicable were the surround and trims installed according to the manual Was the operation of the fan lights if installed and flame modulation checked Customer Tutorial and Presentation YES NO Is the customer confident operating the new gas appliance and aware of all the features on the remote Confirm that the rating and lighting...

Страница 8: ...tured Home Construction and Safety Standard Si ces normes ne sont pas pertinentes utilisez la norme ANSI NCSBCS A225 1 NFPA 501A Manufactured Home Installations Standard ou ANSI A119 2 ou NFPA 501C Standard for Recreational Vehicles Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique Cet appareil peut être installé dans une maison préfabriquée ou mobile...

Страница 9: ...tly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspecti...

Страница 10: ... BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME AREA AS THE APPLIANCE TODDLERS YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENTAL CONTACT BURNS A PHYSICAL BARRIERS IS RECOMMENDED IF THERE ARE AT RISK INDIVIDUAL IN THEHOUSE TORESTRICTACCESSTO A FIREPLACE OR STOVE INSTALL AN ADJUSTABLE SAFETY GATE TO KEEP TODDLERS YOUNG CHILDREN AND OTHER AT RISK INDIVIDUALS OUT OF THE ROOM AND AWAY FROM ...

Страница 11: ... and in good working order and constructed of non combustible materials The surround panels should not seal ventilation openings on the fireplace Chimney clean outs should fit properly NOTE Any alterations made to the listed solid fuel burning factory built fireplace may void the listing of the fireplace Cutting any sheet metal part of the fireplace in which the gas fireplace insert is to be insta...

Страница 12: ...liance should be installed by a qualified gas fitter technician only 2 Installation and repair should be done by a qualified service person 3 The appliance should be inspected before use and at least annually by a professional service person Morefrequentcleaningmayberequired due to excessive lint from carpeting bedding material animal hair etc It is imperative that control compartments burners and...

Страница 13: ...Continue to hold the control knob in until a faint buzzer sound can be heard for 4 seconds informing the operator that the knob can now be released Release knob 3 Push in gas control knob slightly and turn to ON position 4 Ensure the receiver is in the remote position 5 Press and release the ON OFF button on the remote handheld transmitter An audible beep should be heard from the receiver See diag...

Страница 14: ...Turn OFF the main gas supply of the appliance during installation or maintenance of the Receiver device Turn OFF main gas supply to the appliance prior to removing or rein serting the batteries In case of remote control malfunction turn off the IFC device using the ON OFF main switch For installation maintenance switch off the IFC device removing main power supply plug OPERATING PROCEDURE Pairing ...

Страница 15: ...ht by one step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position Fig 7 8 A single beep will confirm reception of the command Fig 7 Fig 8 Room Thermostat Transmitter Operation The Remote Control can operate as a room thermostat Th...

Страница 16: ...rculating fan the speed of the fan can be controlled by the Proflame system The fan speed can be adjustedthroughsix 6 speeds ToactivatethisfunctionusetheModeKey fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adjust the fan speed fig 14 A single beep will confirm reception of the command Figure 13 Figure 14 Remote dimmer control Light The auxiliary ...

Страница 17: ...I IPI Switch The benefits of having CPI are as follows Keeps venting primed for trouble free start up under colder weather conditions or inversions Keeps the unit glass warm which decreases the amount of condensation on start up Provides owners with flexibility to choose a traditional continuous pilot 7 day Pilot on Demand The primary benefit of having the IPI function is a significant savings on ...

Страница 18: ... Replace 4 x AA batteries and insert the battery compartment back into remote receiver battery holder Move both the left right slides as shown below The battery compartment will be pushed out slightly to allow to easily extract it Extract the battery compartment from the remote receiver battery holder Close the right slide Keeping the battery compartment pressed in close the left slide PROFLAME I ...

Страница 19: ...wn in the following diagrams J 8 1 8 Low profile Standard Faceplate CLEARANCES TO COMBUSTIBLES From Unit Sides A 10 255 mm Ceiling B 47 5 1205 mm Mantle C See mantle clearances Max Mantel Depth G 12 305 mm Min Alcove Width K 48 1220 mm Max Alcove Depth L 36 915 mm No Hearth Required Measured from edge of glass frame J GlassFrameWidth ReferenceOnly 26 660mm ...

Страница 20: ...12 6 4 8 10 2 0 12 6 16 4 14 8 18 10 Side View U31 mantle c 12 Mantel 3 1 2 Mantel 19 1 2 to floor 2 0 12 6 4 8 10 2 0 12 6 16 4 14 8 18 10 20 22 24 26 21 25 Side View COMBUSTIBLE MANTEL CLEARANCES IN MASONRY INSTALLATION Clearances for Low Profile Faceplate with Safety Screen Clearances for Contour Faceplate with Safety Screen Louvers ...

Страница 21: ...7 Pull off the pilot cap to expose the pilot orifice 18 Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit 19 Replace Burner Tray and reverse steps 5 to 1 20 Adjust the burner aeration setting to 3 8 to 3 8 as required for the best flame picture Fig 1 9 Removetheblackprotection capbyhandfromthehi low knob Fig 1 Fig 2 12 Flip the screw Fig 3 Fig 4 Fig 3 13...

Страница 22: ...h the front of the unit therefore the front of the unit must be kept clear of any obstructions GAS PRESSURE TEST The unit is preset to give the correct gas input at thespecifiedmanifoldpressuresshownonthelabel The maximum gas manifold pressure is Natural Gas 3 5 w c Propane 10 w c The manifold pressure is controlled by a regulator built into the gas control and should be checked at the pressure te...

Страница 23: ...close all external doors and windows in the house 2 Light the unit and set controls to maximum Turn fan off 3 After five minutes test that there is a pull on the flue by placing a smoke match cigarette or similar device which gives off smoke in front of the spill tube To ensure a valid test place a scrap piece of sheet metal or other noncom bustible material between the spill tube and the upper lo...

Страница 24: ...ool j 902 179 P Vermiculite k 946 669 Platinum Embers supplied with packaged manual Note Install Optional Brick Panels prior to installing logs 1 Carefully remove the logs from the box and unwrap them The logs are fragile handle with care do not force into position 2 Sprinkle the vermiculite around the firebox base Take some of the embers approx 1 3 of the bag and sprinkle over the vermiculite 3 P...

Страница 25: ...Center Log E 02 47 over Log B 02 45 and across the cutout on Log A 02 43 Cutout Pin Cutout Notch 8 Position notch in Front Right Log F 02 48 on Log E 02 47 and push the bottom right edge against the bracket on the burner tray and the front edge of the rear burner Notch Bracket D 02 46 E 02 47 F 02 48 C 02 56 A 02 43 B 02 45 A 02 43 B 02 45 E 0 2 4 7 Logs A 02 43 C 02 56 and B 02 45 in position C 0...

Страница 26: ... rear burner Side View Page 3 of 3 11 Separate platinum embers and place on and around the embers and rockwool on the burner tray Avoid stacking platinum embers Separate the embaglow embers and place at the front of the burner only over the platinum embers rockwool embers 12 Test fire to ensure proper light off make sure flame flows smoothly from one end of burner to the other If there is any flam...

Страница 27: ...held 3 x AAA batteries in order to operate appliance using the remote control CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improperanddangerousoperation WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grou...

Страница 28: ...e faceplate side panels with the screws provided See Diagram 1 3 Using the connectors provided join the left side trim with the ON OFF switch to the top trim Diagram 2 Connect the right side trim to the top trim 4 Placethetrimontheassembledfaceplatepanels aligning the wire connections from the switches with the notch on the left side panel 5 Connect the fan switch wires by taking the black and red...

Страница 29: ...ottom Louver near the hinge Flip hinge over the Bottom Louver and secure using 3 screws FLUSH GLASS INSTALLATION 1 Install upper and lower trim 2 Slide the glass into the bottom glass support and secure with the glass clips using the 2 phillips head screws at the top Note To remove the glass reverse the procedure WARNING The use of substitute glass will void all product warranties Do not operate t...

Страница 30: ...agram 5 Diagram 6 3 Tuck the wires into the clip to keep them away from the insert using the clip provided Attach the clip to the rear of the faceplate to en sure that the wires do not touch the side of the unit The power cord should be run behind the inner faceplate panel 4 Install the on off switch fan speed control box to the left hand bottom leg of the inner faceplate Controls located on the l...

Страница 31: ...anel pins 11 Install safety screen see next page 9 Hook door frame on 2 pins over glass door in locations shown below in Diagram 10 7 Attach 2 brackets near the bottom of the unit with one screw as shown below in Diagram 8 left and right brackets are inter changeable 8 Attach Regency logo to bottom louver Install bottom louver by hanging louver on brackets installed in step 7 Final Install Diagram...

Страница 32: ...on the safety screen into the slots on the unit 3 To remove lift screen assembly up and pull away from unit Note If the top and bottom glass trim supplied with the optional flush louvers is installed discard and recycle the glass trim as this not required when using the safety screen This is only used on previous models of fireplaces which do not use this optional safety screen ...

Страница 33: ... at 15 minutes 2 If required adjusting the primary air to ensure that the flame does not carbon First allow the unit to burn for 15 min to stabilize CAUTION Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibility of the manufacturer Thermostat Wire Table Recommended Maximum Lead Length Two Wire When Using Wall Thermostat...

Страница 34: ... You should also be aware that as there are temperature changes within the unit these sounds will likely re occur Again this is normal for steel fireboxes Blower Thermodisc When this thermally activated switch turns ON it will create a small clicking sound This is the switch contacts closing and is normal Pilot Flame While the pilot flame is on it can make a very slight whisper sound Gas Control V...

Страница 35: ...eexplosion entraînant des dommages des blessures ou la mort Une mauvaise installation un mauvais réglage une modification un mauvais service ou entretien peut provoquer des dommages maté riels ou des blessures Reportez vous au manuel du propriétaire de l information fournie avec cet appareil Pour obtenir de l aide ou des informations supplémentaires consulter un installateur qualifié une agence de...

Страница 36: ... the appliance clear and free from combustible materials gasoline and other flammable vapours and liquids 6 Each time the appliance is lit it may cause condensation and fog the glass This conden sation and fog is normal and will disappear in a few minutes as the glass heats up Never operate the appliance without the glass properly secured in place with broken glass or with the door open 7 Verify p...

Страница 37: ...make sure the fan is seated properly on the pins this is very important try to move the fan back and forth there should be no noise if there is check that the grommets haven t come loose When replacing the Burner Tray slide the aeration adjustment rod through the opening in the front of the Valve Assembly 2 Unplug or disconnect power source to stove 3 Remove the safety screen and glass front see d...

Страница 38: ...censed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Operational changes to look for can include but are not limited to extended start up time increased fan noise residue carbon build up white build up on the glass firebox increased operating noise etc Should any of these or other condition...

Страница 39: ...936 233 3 4 Rope Gasket 404 969 Conversion to LP Kit 919 435 Manual Not available as a replacement part Part Description 1 400 011 Fan Opening Cover 2 911 071 P Fan Motor 120 V 5 910 750 Power Cord 120 V 910 752 Wire Harness intermediate 6 Thermodisc cover 7 Thermodisc bracket 8 910 142 Thermodisc Fan Auto ON OFF 10 404 540 Drafthood Assembly 11 Spill Switch Bracket 12 910 220 Spill Switch 13 Leve...

Страница 40: ... 910 048 Pilot Assembly NG 64 911 248 4 flame convertible Pilot Hood only 63 910 049 Pilot Assemby LP 67 Firebox Base 69 402 935 Log Set 402 572 Ember Package 902 153 Rockwool 946 669 Platinum Bright Embers 946 708 Embaglow Bright Embers 70 Air Channel 72 Glass Trim Retainer 73 Firebox back and top 74 Glass Gasket Retainer 75 404 050 Firebox Baffle 76 400 090 Brick Clip 77 404 005 Fan Access Plate...

Страница 41: ... Oversize Faceplate Assembly 910 330 Fan Speed Controller 904 569 Fan Speed Controller Knob 1 2 4 3 5 LOW PROFILE FACEPLATE Part 403 954 Description Low Profile Faceplate 1 Back plate Assembly 2 Bottom Louver 3 Right mounting bracket 4 Left mounting bracket 5 Front Frame 910 330 Fan Speed Controller 904 569 Fan Speed Controller Knob ...

Страница 42: ...rol Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assemb...

Страница 43: ...ts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the appli...

Страница 44: ...e U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brie...

Страница 45: ...der for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in...

Страница 46: ......

Страница 47: ......

Страница 48: ...e following information Dealer Name Address ________________________________________ ___________________________________________________________ Installer ____________________________________________________ Phone ____________________________________________________ Date Installed ________________________________________________ Serial _____________________________________________________ U31 Vide...

Отзывы: